DOWNLOAD Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man38) Service Manual ↓ Size: 27.15 MB | Pages: 121 in PDF or view online for FREE

Model
MX-4100N MX-4101N MX-5000N MX-5001N (serv.man38)
Pages
121
Size
27.15 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Installation Manual-(Complete Manual)
File
mx-4100n-mx-4101n-mx-5000n-mx-5001n-sm38.pdf
Date

Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man38) Service Manual ▷ View online

MX-4100N  MX-SMX3  23 – 3
9)
Attach the ozone filter cover to the main unit.
• Reconnect the cables that have been removed in step B to
the original positions of the control PWB unit.
E. Turn on the main power switch of the main 
unit.
1)
Insert the power plug of the main unit to the outlet.
2)
Turn on the main power switch.
3)
Turn on the power switch located on the operation panel.
ON
<State of switch>
ON
OFF
MX-4100N  Dehumidifying heater  24 – 1
MX-4100N
Service Manual
 
[24] Dehumidifying heater
1.  Parts included
2.  Installation
<Note before installation>
Before starting installation, check to insure that the data lamp on
the operation panel does not light up or blink.
A. Removal of the rear cabinet and the left rear 
lower cabinet 
1)
Remove the screw, and remove the rear cabinet.
2)
Remove the screw, and remove the left rear lower cabinet.
Kit name
Kit  part code
Package 
part No.
Description
Part code
Price 
rank
Q'ty
Remarks
Heater electric 
component kit
DKIT-0391FCZZ
1
Dehumidifier heater switch
QSW-C9294QCZZ
AF
1
2
Label for heater switch
TLABZ5256FCZZ
AH
1
3
Supporter
LSUPP0118FCPZ
AB
5
4
WH PWB
CPWBF1675FC338
AQ
1
5
AC-WH harness 1
DHAI-3755FCZZ
AH
1
AC-WH harness 2
DHAI-3756FCZZ
AE
1
Not used in this model
Heater kit
DKIT-0385FCZZ 
(120V series)
DKIT-0386FCZZ 
(230V series)
6
Heater  (120V series)
RHETP0131FCPZ
BE
1
Heater  (230V series)
RHETP0132FCPZ
BE
7
Heater mounting plate
LPLTM6089FCZZ
AK
1
8
Screw (M3x6 S-tight)
XHBS730P06000
AC
3
9
T-Heater cover
PCOVP1654FCZ2
AN
1
10
Caution label (For high temperature)
TCAUH1035FCZZ
AC
1
11
Screw (M3x5 S-tight)
XHBS730P05000
AA
1
12
Omega lock
LHLDW1334FCZZ
AA
1
Scanner heater kit
DKIT-0373FCZZ
13
Scanner heater
RHETP0127FCZZ
AX
1
14
Heater fixing plate
LPLTM6923FCZZ
AG
1
15
Banding band
LBNDJ0013FCZ1
AE
2
16
Clamp
LHLDW7011XCZZ
AB
5
17
Screw (M3x4 Round-tipped)
LX-BZ1041FCZZ
AB
2
18
Screw (M4x6 Bind machine screw)
XBBS740P06000
AA
1
19
Snap band
LBNDJ0043FCZZ
AA
1
Desk heater kit
20
Desk heater (120V series)
1
Desk heater (230V series)
21
Heater heat sink
1
22
Screw (M3x4 S-tight)
4
23
Desk heater mounting plate
1
24
Edge wire saddle
1
25
Screw (M3x8 S-tight)
2
26
Caution label (For high temperature)
1
27
Desk heater harness (120V series)
1
Desk heater harness (230V series)
28
Washer
1
29
Screw (M4x8 K)
1
30
Mini clamp
1
MX-4100N  Dehumidifying heater  24 – 2
B. Installation of the heater electric component 
kit
(1) Attaching the dehumidifier heater switch
1)
Attach the dehumidifier heater switch (package part No. 1) to
the frame.
NOTE: Install the dehumidifier heater switch so that the side of the
mounting terminal post is the inward side of the main unit.
2)
Cut the switch part of the left rear lower cabinet.
NOTE: Be careful not to damage the cabinet.
3)
Attach the label for heater switch  (package part No. 2)  to the
left rear lower cabinet.
NOTE: Wipe the surface where the label is to be affixed with alco-
hol, then attach the label along the concave on left rear
lower cabinet.
(2) Installation of the WH PWB
1)
Remove the screw, and remove the AC-cable connection plate
(only for 120V series), or remove the inlet mounting plate (only
for 230V series).
Remove the core (This procedure only applies to the 230V
series).
2)
Remove the snap band. Insert the supporter (package part No.
3) to the frame of the power unit, and attach the WH PWB
(package part No. 4) on it.
NOTE: Be careful not to break the PWB when mounting the PWB
to the supporters.
3)
Connect the harness to the WH PWB.
DH
PO
WER
120V Series
230V Series
MX-4100N  Dehumidifying heater  24 – 3
4)
Connect the AC-WH harness 1 (package part No. 5) to the AC
PWB, the WH PWB and the dehumidifier heater switch.
NOTE: The AC-WH harness 1 should pass under the MSW har-
ness.
C. Installation of the heater kit
(1) Assembling of the heater unit
1)
Attach the heater (package part No. 6) to the heater mounting
plate (package part No. 7), and secure it with the screw (M3x6
S-tight) (package part No. 8).
2)
Attach the heater mounting plate to the T-Heater cover (pack-
age part No. 9), and secure it with the screw (M3x6 S-tight)
(package part No. 8).
Attach the snap band of the heater harness to the T-Heater
cover.
NOTE: After installing, check that the harness of the heater go
straight into the T-Heater cover.
3)
Attach the caution label (package part No. 10) to the T-Heater
cover.
NOTE: Wipe the surface where the label is to be affixed with alco-
hol, then attach the label along the reference line.
(2) Installation of the heater unit
1)
Remove the tray 1 and the tray 2.
2)
Install the heater unit to the main unit, and secure it with the
screw (M3x5 S-tight) (package part No.11).
Pass the harness of the heater through the hole on the main
unit frame, and attach the snap band.
Reference line
Reference
line
Page of 121
Display

Click on the first or last page to see other MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man38) service manuals if exist.