DOWNLOAD Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man10) Service Manual ↓ Size: 42.66 MB | Pages: 126 in PDF or view online for FREE

Model
MX-2640N MX-2640NR MX-2640FN MX-3140N MX-3140NR MX-3140FN MX-3640N MX-3640NR MX-3640FN (serv.man10)
Pages
126
Size
42.66 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Installation Manual Revised June 2014.
File
mx-2640n-mx-2640nr-mx-2640fn-mx-3140n-mx-3140nr-mx.pdf
Date

Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man10) Service Manual ▷ View online

MX-3640N  Dehumidifying heater  3 – 15
E. LCC heater kit installation
(1) Paper feed unit removal
1) Pull out the paper feed tray.
2) Open the upper cover.
3) Remove the upper cabinet.
4) Disconnect the connector, and remove the paper feed unit.
(2) Heater cover and cabinet removal
1) Remove the heater cover.
2) Remove the cabinet.
(3) Heater attachment
1) Attach the heater.
1
1
2
2
3
1
2
1
2
1
1
2
1
2
2
1
MX-3640N  Dehumidifying heater  3 – 16
2) Attach the protect sheet.
(4) Heater harness unit attachment
1) Attach the snap band of the heater harness unit. While holding
the harness upward, attach the AC cord fixer.
After  attaching  the snap band, cut and tr im  the  end of the
band.
Be careful not to mistake the attaching direction of the AC cord
fixer.
2) Pull  the  harness  tightly  in  the  arrow  direction,  and  check  to
confirm  that  there is  no  disconnection  of  the  snap  band  and
that the square hole in the  frame is not covered  with the har-
ness.
3) Connect the connector of the heater harn ess unit, and attach
the earth wire.
Attach the earth wire at an angle of 45 degrees.
(5) Cabinet and heater cover attachment
1) Attach the cabinet.
2) Attach the heater cover.
75
˴5mm
r
0
˴
2mm
2
1
45q
2
1
2
1
MX-3640N  Dehumidifying heater  3 – 17
(6) Paper feed unit attachment
1) Attach the paper feed unit.
2) Attach the upper cabinet.
3) Close the upper cover.
4) Insert the paper feed tray.
(7) Connector connection
1) Remove the connector cover.
2) Connect the connector, and tighten the screw.
F. Operation check after installation
1) Turn on the dehumidifier heater switch.
2) Measure the resistance value between the earth terminal and
the AC terminal  (L side), and between the ea rth terminal and
AC terminal  (N side)  with  the circuit  tester,  and conf irm  they
are not short-circuited.
3) When not using the dehumidifier heater after checking, turn off
the dehumidifier heater switch.
2
1
2
2
1
3
3
2
2
1
1
2
MX-3640N  MX-DE12/DE13/DE14 (STAND/1x500/2x500/3x500 SHEET PAPER DRAWER)  4 – 1
MX-3640N
Service Manual
 
[4] MX-DE12/DE13/DE14 (STAND/1x500/2x500/3x500 SHEET PAPER 
DRAWER)
1.  Unpacking
If  the  connector is removed first,  it  may be damaged   during  the 
installation  procedures.  Therefore,  keep  it  packed  while  un-box-
ing.    and  unpack  it only  when  connecting  the connector   to the 
machine.
A. Packed items check
2.  Installation
Before  installation,  be  sure  to  turn  both the oper ation  and main 
power switches off and disconnect the power plug from the power 
outlet. Make double sure that the data lamp on the operation panel 
does not light up or blink when performing installation. 
A. Adjuster attachment
1) Turn each adjuster to fix the desk unit.
B. Main unit and desk unit connection
1) Put the main unit on the desk unit.
Use man power of four persons or more to lift the main unit.
Place the main unit on the desk unit slowly by fitting the exter-
nal lines. Check to insure that the positioning pin on the top of 
the desk unit is securely engaged in the positioning groove of 
the main unit.
2) Remove the tray 1 and the tray 2.
No.
Name
Quantity
1
Desk unit
1
2
Fixing screws (M3 x 8)
4
3
Connection cover
2
1
3
2
Page of 126
Display