DOWNLOAD Sharp MX-2630 (serv.man2) Service Manual ↓ Size: 96.88 MB | Pages: 127 in PDF or view online for FREE

Model
MX-2630 (serv.man2)
Pages
127
Size
96.88 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual
File
mx-2630-sm2.pdf
Date

Sharp MX-2630 (serv.man2) Service Manual ▷ View online

MX-2630N  ADJUSTMENTS AND SETTINGS  5 – 15
Check Method 2
Check that the squareness of the main scanning direction print
line for the longitudinal direction of paper is within 1.0 mm.
If the copy image is not in the above state, perform the proce-
dure 3).
3) Open the RSPF unit, and loosen the fixing screw of the hinge.
4) Slide the RSPF unit in the arrow direction to make the skew
adjustment.
5) Make a copy again and measure a and b on the copied test
chart. Repeat procedures 2) to 5) until the condition (a - b = ± 1
mm or less) is satisfied.
 
ADJ 8
Scan image focus adjustment
 
8-A
Image focus adjustment (Document table 
mode/RSPF front surface mode)
This adjustment must be performed in the following cases:
• The CCD unit has been removed from the machine.
• The CCD unit has been replaced.
• When the copy image focus is not properly adjusted.
• When the copy magnification ratio in the copy image main scan-
ning direction is not properly adjusted.
• U2 trouble has occurred.
1) Enter the SIM 48-1 mode.
2) Set the adjustment item CCD (MAIN) to 50 (default value).
Select the adjustment item with the scroll key, and enter the
adjustment value with 10-key and press [OK] key.
3)
Place a scale on the original table as illustrated below.
4)
Make a normal copy on A4 paper.
5)
Compare the copied image of the scale and the actual scale
length in terms of length.
6)
Obtain the copy magnification ratio correction ratio in the main
scanning direction from the following formula.
Main scanning direction copy magnification ratio correction
ratio = (Original size - Copy image size) / Original size x 100%
(Example)
Compare the scale of 10 mm with the scale of 10 mm on the
copy image.
Main scanning direction copy magnification ratio correction
ratio = (100 - 99) / 100 x 100 = 1
If the copy magnification ratio is not satisfactory, perform the
following procedures.
7)
Remove the document table glass.
8)
Remove the dark box cover.
A
1.0
10
20
90
100
110
10
20
90
100
110
1.0mm
100 mm scale
(Original)
Copy image
(1mm (1%) 
shorter than 
the original)
MX-2630N  ADJUSTMENTS AND SETTINGS  5 – 16
9) To prevent against shift of the CCD unit optical axis, mark the
CCD unit base as shown below.
This procedure must be executed also when the CCD unit is
replaced.
10) Loosen the CCD unit fixing screws.
NOTE: Never loosen the screws marked with X.
If any one of these screws is loosened, the position and the
angle of the CCD unit base may be changed to cause a
problem, which cannot be adjusted in the market. In that
case, the whole scanner unit must be replaced.
11) Slide the CCD unit in the arrow direction (CCD sub scanning
direction) to change the installing position.
When the copy image is longer than the original scale, shift the
CCD unit in the direction B. When the copy image is shorter
than the original scale, shift the CCD unit in the direction A.
One scale of mark-off line corresponds to 0.2%.
At that time, fix the CCD unit so that it is in parallel with the
scale on the front and the rear side of the CCD unit base.
* Fix the CCD unit so that it is in parallel with the line marked in
procedure 9).
12) Make a copy and check the copy magnification ratio again.
If the copy magnification ratio is not in the range of 100 ± 0.8%,
repeat the procedures of 9) - 11) until the condition is satisfied.
NOTE: By changing the CCD unit fixing position with the simula-
tion 48-1 adjustment value at 50, the copy magnification
ratio is adjusted within the specified range (100 ± 0.8%)
and the specified resolution is obtained based on the opti-
cal system structure.
 
ADJ 9
Scan image magnification ratio 
adjustment (Manual 
adjustment)
 
9-A
Scan image magnification ratio adjustment 
(main scanning direction) (Manual 
adjustment) (Document table mode)
NOTE: If the default adjustment value of the scan image magnifi-
cation ration adjustment (main scanning direction) of SIM
48-1 is changed, copy image quality may be degraded.
Therefore, this adjustment must be executed only when
there is a special necessity.
This adjustment must be performed in the following cases:
• When the copy magnification ratio in the copy image main scan-
ning direction is not properly adjusted.
• When the scanner motor is replaced.
• U2 trouble has occurred.
• When the SCN-MFP control PWB is replaced.
• When the EEPROM of the SCN-MFP control PWB is replaced.
Before this adjustment, the focus adjustment (CCD unit installing
position adjustment) must have been completed.
1)
Place a scale on the document table as shown in the figure
below.
2)
Enter the SIM 48-1 mode.
3)
Make a normal copy and obtain the copy magnification ratio.
Press [CLOSE] key to shift from the simulation mode to the
copy mode, and make a copy.
4)
Check that the copy magnification ratio is within the specified
range (100 ± 0.8%).
If the copy magnification ratio is within the specified range (100
± 0.8%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5)
Change the CCD (MAIN) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio is increased.
A
B
MX-2630N  ADJUSTMENTS AND SETTINGS  5 – 17
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.02%.
Repeat the procedures 3) - 5) until the copy magnification ratio
is within the specified range (100 ± 0.8%).
 
9-B
Scan image magnification ratio adjustment 
(sub scanning direction) (Manual 
adjustment) (Document table mode)
This adjustment must be performed in the following cases:
• When the copy magnification ratio in the copy image sub scan-
ning direction is not properly adjusted.
• When the scanner motor is replaced.
• U2 trouble has occurred.
• When the SCN-MFP control PWB is replaced.
• When the EEPROM of the SCN-MFP control PWB is replaced.
1) Place a scale on the document table as shown in the figure
below.
2) Enter the SIM 48-1 mode.
3) Make a normal copy and obtain the copy magnification ratio.
Go to the copy mode, and make a copy.
4) Check that the copy magnification ratio is within the specified
range (100 ± 0.8%).
If the copy magnification ratio is within the specified range (100
± 0.8%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5)
Change the CCD (SUB) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio in the sub scanning direction is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.1%.
Repeat the procedures 3) - 5) until the copy magnification ratio
is within the specified range (100 ± 0.8%).
 
9-C
Scan image magnification ratio adjustment 
(main scanning direction) (Manual 
adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
• When the SCN-MFP control PWB is replaced.
• When the EEPROM on the SCN-MFP control PWB is replaced.
• When U2 trouble occurs.
• When the copy magnification ratio of the RSPF mode copy
image in the main scanning direction is not proper.
• When the RSPF is disassembled.
a. Adjustment procedures
1)
Place the duplex adjustment chart shown below on the docu-
ment tray of the RSPF.
The adjustment chart is prepared by the following procedures.
Use A4 (11" x 8.5") paper, and put marks on both sides and
both surfaces of the paper at 10mm from each edge.
2)
Make a duplex copy at the normal ratio on A4 paper.
3)
Measure the images on the copy paper and the original
images.
4)
Obtain the image magnification ratio according to the following
formula:
Image magnification ratio = Original size / Original size x 100
(%)
Image magnification ratio = 99 / 100 x 100 = 99 (%)
If the image magnification ratio is within the specified range
(100 ± 0.8%), there is no need to perform the adjustment.
If it is not within the specified range, perform the following pro-
cedures.
5)
Enter the SIM 48-1 mode.
10
20
90
100
110
10
20
90
100
110
10
20
90
100
110
Copy magnifi-
cation ratio
(Original dimension - Copy dimension)
Original dimension
X 100%
(Example 1)
Copy A
(Shorter than
the original)
Scale
(Original)
(Example 2)
Copy B
(Longer than
the original)
10mm
10mm
Paper pass direction
A4 size
(Both the front surface 
and the back surface)
original
10
50
100
150
200
250
copy
10
50
100
150
200
250
MX-2630N  ADJUSTMENTS AND SETTINGS  5 – 18
6) Select an adjustment item of SPF (MAIN)/SPFB (MAIN) with
the scroll key.
7) Enter an adjustment value with 10-key, and press [OK] key.
When the adjustment value is increased, the image magnifica-
tion ratio is increased. When the adjustment value is changed
by 1, the image magnification ratio is changed by 0.02%
8) Make a normal copy and obtain the copy magnification ratio.
Repeat the procedures of 1) - 8) until a satisfactory result is
obtained.
 
9-D
Scan image magnification ratio adjustment 
(sub scanning direction) (Manual 
adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
• When the SCN-MFP CONTROL PWB is replaced.
• When the EEPROM on the SCN-MFP CONTROL PWB is
replaced.
• When U2 trouble occurs.
• When the copy magnification ratio of the RSPF mode copy
image in the sub scanning direction is not proper.
• When the RSPF is disassembled.
1) Place the duplex adjustment chart shown below on the docu-
ment tray.
The adjustment chart is prepared by the following procedures.
Use A4 (11" x 8.5") paper, and put marks on both sides and
both surfaces of the paper at 10mm from each edge.
2) Make a duplex copy at the normal ratio on A4 paper.
3) Measure the images on the copy paper and the original
images.
4)
Obtain the image magnification ratio according to the following
formula:
Image magnification ratio = Original size / Original size x 100
(%)
Image magnification ratio = 99 / 100 x 100 = 99 (%)
If the image magnification ratio is within the specified range
(100 ± 0.8%), there is no need to perform the adjustment.
If it is not within the specified range, perform the following pro-
cedures.
5)
Enter the SIM 48-1 mode.
6)
Select an adjustment item with the scroll key.
7)
Enter an image magnification ratio adjustment value with 10-
key, and press [OK] key.
When the adjustment value is increased, the image magnifica-
tion ratio is increased. When the adjustment value is changed
by 1, the image magnification ratio is changed by 0.1%.
8)
Make a normal copy and obtain the copy magnification ratio.
Repeat the procedures of 1) - 8) until a satisfactory result is
obtained.
 
ADJ 10
Scan image off-center 
adjustment (Manual 
adjustment)
 
10-A
Scan image off-center adjustment (Manual 
adjustment) (Document table mode)
This adjustment must be performed in the following cases:
• When the scanner (reading) section is disassembled.
• When the scanner (reading) unit is replaced.
• When a U2 trouble occurs.
• When the SCN-MFP control PWB is replaced.
• When the EEPROM on the SCN-MFP control PWB is replaced.
1)
Make a copy of the adjustment chart (using the document
table) in the adjustment mode.
SPF(MAIN)
Main scanning direction image magnification ratio 
(Front surface)
SPFB(MAIN)
Main scanning direction image magnification ratio 
(Back surface)
A4 size
10mm
10mm
Paper pass direction
original
copy
10
50
100
150
200
10
50
100
150
200
SPF(SUB)
Sub scanning direction image magnification ratio 
(Front surface)
SPFB(SUB)
Sub scanning direction image magnification ratio
(Back surface)
$
#$
#
Page of 127
Display