Sharp MX-2600N / MX-3100N / MX-2600G / MX-3100G (serv.man51) Service Manual / Technical Bulletin ▷ View online
CCE 620R
4) Fix the dehumidifier heater switch (QSW-C9294QCZZ) on the left posterior frame.
* Terminals of the switch should be on the inward side.
5) Fix the posterior inferior part on the left-side cabinet. (2 screws)
6) Affix the heater switch label (TLABZ5256FCZZ).
6)-1. Wipe the surface where the label is to be affixed with alcohol.
6)-2. Affix the label onto the concave on the posterior inferior part on the left-side cabinet.
6)-3. Make sure that the label is completely affixed by pressing the entire surface of the label.
6)-2. Affix the label onto the concave on the posterior inferior part on the left-side cabinet.
6)-3. Make sure that the label is completely affixed by pressing the entire surface of the label.
* Check that there are no air-bubbles, and wrinkles on the label when affixed.
Check that the label is affixed straight.
* Do not touch the glue surface. Never reuse the failed labels.
- Page 2
CCE 620R
7) Remove the AC-cable connection plate (machines in 120V series), or remove the inlet fixing plate
(machines in 230V series).
(machines in 230V series).
8) Remove the reactor (This procedure only applies to the 230V series).
9) Fix the WH PCB mount-supporters (LSUPP0118FCPZ) (Five supporters).
10) WH PCB (CPWBF1675FC338) Mounting
* Be careful not to break the PCB when mounting onto the supporters.
- Page 3
CCE 620R
11) Connect the WH-DESK-LCC harness to the WH PCB (white connector).
12) Connection Method of AC-WH Harness 1 (DHAI-3755FCZZ)
(WH PCB
AC PCB
Heater Switch)
* AC-WH harness 1 should pass under the MSW harness.
13) Connect the harness for WH PWB control (3 pin connector in red), which is branched from the DC main
harness on the main unit, to WH PWB.
- Page 4
Procedure13
Connect the harness for WH PWB control (3 pin connector in red),
which is branched from the DC main harness on the main unit, to WH
CCE 620R
14) Fix the reactor (This procedure only applies to the 230V series).
15) Fix the AC cable connection plate (machines in the 120V series), or fix the inlet fixing plate (machines
15) Fix the AC cable connection plate (machines in the 120V series), or fix the inlet fixing plate (machines
in the 230V series).
* Make sure that no cables should be stuck anywhere.
* Make sure that no cables should be stuck anywhere.
16) Fix the rear plate (11 screws).
- Page 5
Procedure14
Procedure15
Procedure16
Click on the first or last page to see other MX-2600N / MX-3100N / MX-2600G / MX-3100G (serv.man51) service manuals if exist.