Sharp MX-2314N (serv.man45) Service Manual / Technical Bulletin ▷ View online
Sharp Electronics (UK) Ltd., Document Systems Support
5/5
1. When replacing either of the lens unit, lamp unit (LED driver PWB) or scanner control PWB from
the old parts to the new parts, all of the lens unit, lamp unit (LED driver PWB) and scanner
control PWB need to be replaced to the new parts.
Firmware version also needs to be updated to the following versions or later.
Target model
ICU
SCU
MX-2314N/2614N/3114N/2615N/3115N/2616N/3116N
0700G200
0200G200
MX-M264N/M314N/M354N/M264U/M314U/M354U
u500c100
0200c100
2. When replacing either the lens unit, lamp unit (LED driver PWB) or scanner control PWB from
the new parts to the old parts, all of the lens unit, lamp unit (LED driver PWB) and scanner
control PWB need to be replaced to the old parts. However, it does not matter whether the
firmware is old or new version.
3. On MX-2314N/2614N/3114N/2615N/3115N/2616N/3116N, please perform the following
procedure:
Action items when replacing the old lens unit with the new lens unit or replacing the new lens
with the old lens;
Target used for the auto adjustment of color balance is automatically switched due to the
replacement of the scanner (old->new/new->old) but the service target is not automatically
switched.
When the auto adjustment is carried out at the time of serving or it is done by the user,
the following procedure is required not to use the old target:
1.
Enter
SIM63-8.
2.
Press
EXECUTE.
3.
Press
YES.
4. Get out of SIM63-8.
5.
Enter
SIM67-28.
6.
Press
EXECUTE.
7.
Press
YES.
8. Get out of SIM67-28.
Sharp Electronics (UK) Ltd., Document Systems Support
5/5
1. When replacing either of the lens unit, lamp unit (LED driver PWB) or scanner control PWB from
the old parts to the new parts, all of the lens unit, lamp unit (LED driver PWB) and scanner
control PWB need to be replaced to the new parts.
Firmware version also needs to be updated to the following versions or later.
Target model
ICU
SCU
MX-2314N/2614N/3114N/2615N/3115N/2616N/3116N
0700G200
0200G200
MX-M264N/M314N/M354N/M264U/M314U/M354U
u500c100
0200c100
2. When replacing either the lens unit, lamp unit (LED driver PWB) or scanner control PWB from
the new parts to the old parts, all of the lens unit, lamp unit (LED driver PWB) and scanner
control PWB need to be replaced to the old parts. However, it does not matter whether the
firmware is old or new version.
3. On MX-2314N/2614N/3114N/2615N/3115N/2616N/3116N, please perform the following
procedure:
Action items when replacing the old lens unit with the new lens unit or replacing the new lens
with the old lens;
Target used for the auto adjustment of color balance is automatically switched due to the
replacement of the scanner (old->new/new->old) but the service target is not automatically
switched.
When the auto adjustment is carried out at the time of serving or it is done by the user,
the following procedure is required not to use the old target:
1.
Enter
SIM63-8.
2.
Press
EXECUTE.
3.
Press
YES.
4. Get out of SIM63-8.
5.
Enter
SIM67-28.
6.
Press
EXECUTE.
7.
Press
YES.
8. Get out of SIM67-28.
Sharp Electronics (UK) Ltd., Document Systems Support
5/5
1. When replacing either of the lens unit, lamp unit (LED driver PWB) or scanner control PWB from
the old parts to the new parts, all of the lens unit, lamp unit (LED driver PWB) and scanner
control PWB need to be replaced to the new parts.
Firmware version also needs to be updated to the following versions or later.
Target model
ICU
SCU
MX-2314N/2614N/3114N/2615N/3115N/2616N/3116N
0700G200
0200G200
MX-M264N/M314N/M354N/M264U/M314U/M354U
u500c100
0200c100
2. When replacing either the lens unit, lamp unit (LED driver PWB) or scanner control PWB from
the new parts to the old parts, all of the lens unit, lamp unit (LED driver PWB) and scanner
control PWB need to be replaced to the old parts. However, it does not matter whether the
firmware is old or new version.
3. On MX-2314N/2614N/3114N/2615N/3115N/2616N/3116N, please perform the following
procedure:
Action items when replacing the old lens unit with the new lens unit or replacing the new lens
with the old lens;
Target used for the auto adjustment of color balance is automatically switched due to the
replacement of the scanner (old->new/new->old) but the service target is not automatically
switched.
When the auto adjustment is carried out at the time of serving or it is done by the user,
the following procedure is required not to use the old target:
1.
Enter
SIM63-8.
2.
Press
EXECUTE.
3.
Press
YES.
4. Get out of SIM63-8.
5.
Enter
SIM67-28.
6.
Press
EXECUTE.
7.
Press
YES.
8. Get out of SIM67-28.
Sharp Electronics (UK) Ltd., Document Systems Support
5/5
1. When replacing either of the lens unit, lamp unit (LED driver PWB) or scanner control PWB from
the old parts to the new parts, all of the lens unit, lamp unit (LED driver PWB) and scanner
control PWB need to be replaced to the new parts.
Firmware version also needs to be updated to the following versions or later.
Target model
ICU
SCU
MX-2314N/2614N/3114N/2615N/3115N/2616N/3116N
0700G200
0200G200
MX-M264N/M314N/M354N/M264U/M314U/M354U
u500c100
0200c100
2. When replacing either the lens unit, lamp unit (LED driver PWB) or scanner control PWB from
the new parts to the old parts, all of the lens unit, lamp unit (LED driver PWB) and scanner
control PWB need to be replaced to the old parts. However, it does not matter whether the
firmware is old or new version.
3. On MX-2314N/2614N/3114N/2615N/3115N/2616N/3116N, please perform the following
procedure:
Action items when replacing the old lens unit with the new lens unit or replacing the new lens
with the old lens;
Target used for the auto adjustment of color balance is automatically switched due to the
replacement of the scanner (old->new/new->old) but the service target is not automatically
switched.
When the auto adjustment is carried out at the time of serving or it is done by the user,
the following procedure is required not to use the old target:
1.
Enter
SIM63-8.
2.
Press
EXECUTE.
3.
Press
YES.
4. Get out of SIM63-8.
5.
Enter
SIM67-28.
6.
Press
EXECUTE.
7.
Press
YES.
8. Get out of SIM67-28.
Display