DOWNLOAD Sharp DM-1500 (serv.man2) Service Manual ↓ Size: 6.56 MB | Pages: 127 in PDF or view online for FREE

Model
DM-1500 (serv.man2)
Pages
127
Size
6.56 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR1500 1505-Service Manual
File
dm-1500-sm2.pdf
Date

Sharp DM-1500 (serv.man2) Service Manual ▷ View online

PIN
No.
Pin name
Signal name
IN/OUT
Destination
Function
85
V
SS
GND
IN
GND
86
V
CC
3.3V
IN
Power source
87
SYSAD17
SYSAD17
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
88
SYSAD49
SYSAD49
IN/OUT
ASIC (KZ4H167V06), 74LVC244
System address data bus
89
INT0
INTR0_
IN
ASIC(KZ4H167V06)
ASIC interruption 0
90
SYSAD18
SYSAD18
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
91
V
SS
GND
IN
GND
92
V
CC
3.3V
IN
Power source
93
SYSAD50
SYSAD50
IN/OUT
ASIC (KZ4H167V06), 74LVC244
System address data bus
94
VALID IN
VALIN_
IN
ASIC (KZ4H167V06)
VALID INPUT (from ASIC)
95
SYSAD19
SYSAD19
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
96
SYSAD51
SYSAD51
IN/OUT
ASIC (KZ4H167V06), 74LVC244
System address data bus
97
V
SS
GND
IN
GND
98
V
CC
3.3V
IN
Power source
99
VALID OUT
VALOUT_
OUT
ASIC (KZ4H167V06)
VALID OUTPUT(to ASIC)
100
SYSAD20
SYSAD20
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
101
N.C
N.C
N.C
102
N.C
N.C
N.C
103
N.C
N.C
N.C
104
N.C
N.C
N.C
105
N.C
N.C
N.C
106
N.C
N.C
N.C
107
N.C
N.C
N.C
108
N.C
N.C
N.C
109
N.C
N.C
N.C
110
N.C
N.C
N.C
111
N.C
N.C
N.C
112
N.C
N.C
N.C
113
N.C
N.C
N.C
114
SYSAD52
SYSAD52
IN/OUT
ASIC (KZ4H167V06), 74LVC244
System address data bus
115
EXT RQST
EXTRQ_
IN
ASIC(KZ4H167V06)
External request
116
V
CC
3.3V
IN
Power source
117
V
SS
GND
IN
GND
118
SYSAD21
SYSAD21
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
119
SYSAD53
SYSAD53
IN/OUT
ASIC (KZ4H167V06), 74LVC244
System address data bus
120
RDRDY
READY_
IN
ASIC(KZ4H167V06)
External IC read ready
121
MODEIN
MODEIN
IN
ASIC(KZ3H008302)
Boot mode data input
122
SYSAD22
SYSAD22
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
123
SYSAD54
SYSAD54
IN/OUT
ASIC (KZ4H167V06)
System address data bus
124
V
CC
3.3V
IN
Power source
125
V
SS
GND
IN
GND
126
RELEASE
RLS_
OUT
ASIC(KZ4H167V06)
Interface open state
DM-1505
11  – 16
PIN
No.
Pin name
Signal name
IN/OUT
Destination
Function
127
SYSAD23
SYSAD23
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
128
SYSAD55
SYSAD55
IN/OUT
ASIC (KZ4H167V06)
System address data bus
129
NMI
NMI_
IN
ASIC(KZ4H167V06)
Non-maskable interruption
130
V
CC
3.3V
IN
Power source
131
V
SS
GND
IN
GND
132
SYSADC2
3.3V
IN
Power source
133
SYSADC6
3.3V
IN
Power source
134
SYSAD24
SYSAD24
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
135
V
CC
3.3V
IN
Power source
136
V
SS
GND
IN
GND
137
SYSAD56
SYSAD56
IN/OUT
ASIC (KZ4H167V06)
System address data bus
138
SYSAD25
SYSAD25
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
139
SYSAD57
SYSAD57
IN/OUT
ASIC (KZ4H167V06)
System address data bus
140
V
CC
3.3V
IN
Power source
141
V
SS
GND
IN
GND
142
N.C
N.C
N.C
143
SYSAD26
SYSAD26
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
144
SYSAD58
SYSAD58
IN/OUT
ASIC (KZ4H167V06)
System address data bus
145
N.C
N.C
N.C
146
V
CC
3.3V
IN
Power source
147
V
SS
GND
IN
GND
148
SYSAD27
SYSAD27
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
149
N.C
N.C
N.C
150
N.C
N.C
N.C
151
N.C
N.C
N.C
152
N.C
N.C
N.C
153
N.C
N.C
N.C
154
N.C
N.C
N.C
155
N.C
N.C
N.C
156
N.C
N.C
N.C
157
N.C
N.C
N.C
158
N.C
N.C
N.C
159
SYSAD59
SYSAD59
IN/OUT
ASIC (KZ4H167V06)
System address data bus
160
COLD RESET
COLDRES_
IN
ASIC(KZ4H167V06)
Clod reset
161
SYSAD28
SYSAD28
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
162
V
CC
3.3V
IN
Power source
163
V
SS
GND
IN
GND
164
SYSAD60
SYSAD60
IN/OUT
ASIC (KZ4H167V06)
System address data bus
165
RESET
CPURES_
IN
ASIC(KZ4H167V06)
CPU reset
166
SYSAD29
SYSAD29
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
167
SYSAD61
SYSAD61
IN/OUT
ASIC (KZ4H167V06)
System address data bus
DM-1505
11  – 17
PIN
No.
Pin name
Signal name
IN/OUT
Destination
Function
168
SYSAD30
SYSAD30
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
169
V
CC
3.3V
IN
Power source
170
V
SS
GND
IN
GND
171
SYSAD62
SYSAD62
IN/OUT
ASIC (KZ4H167V06)
System address data bus
172
SYSAD31
SYSAD31
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH
System address data bus
173
SYSAD63
SYSAD63
IN/OUT
ASIC (KZ4H167V06)
System address data bus
174
V
CC
3.3V
IN
Power source
175
V
SS
GND
IN
GND
176
V
CC
 OK
VCCOK
IN
ASIC (KZ4H167V06),
ASIC(KZ3H008302)
V
CC
 states effective
177
SYSADC3
IN
NC (3.3V pull up)
178
SYSADC7
IN
NC (3.3V pull up)
179
N.C
N.C
N.C
180
N.C
N.C
N.C
181
N.C
N.C
N.C
182
N.C
N.C
N.C
183
N.C
N.C
N.C
184
N.C
N.C
N.C
185
V
CC
P
3.3V
IN
Power source
186
V
SS
P
GND
IN
GND
187
MASTER CLOCK
MASTERCLK
IN
ASIC(KZ4H167V06), PLL
IC(CY2292)
Master clock
188
V
CC
3.3V
IN
Power source
189
V
SS
GND
IN
GND
190
SYSADC5
IN
NC (3.3V pull up)
191
SYSADC1
IN
NC (3.3V pull up)
192
V
CC
3.3V
IN
Power source
193
V
SS
GND
IN
GND
194
SYSAD47
SYSAD47
IN/OUT
ASIC (KZ4H167V06), 74LVC16244
System address data bus
195
SYSAD15
SYSAD15
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH, 74LVC16245
System address data bus
196
SYSAD46
SYSAD46
IN/OUT
ASIC (KZ4H167V06), 74LVC16244
System address data bus
197
V
CC
3.3V
IN
Power source
198
V
SS
GND
IN
GND
199
SYSAD14
SYSAD14
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH, 74LVC16245
System address data bus
200
SYSAD45
SYSAD45
IN/OUT
ASIC (KZ4H167V06), 74LVC16244
System address data bus
201
SYSAD13
SYSAD13
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH, 74LVC16245
System address data bus
202
SYSAD44
SYSAD44
IN/OUT
ASIC (KZ4H167V06), 74LVC16244
System address data bus
203
V
SS
GND
IN
GND
204
V
CC
3.3V
IN
Power source
205
SYSAD12
SYSAD12
IN/OUT
ASIC(KZ4H167V06), 16M FLASH,
8M FLASH, 74LVC16245
System address data bus
206
SYSCMDP
IN
NC (3.3V pull up)
207
SYSAD43
SYSAD43
IN/OUT
ASIC(KZ4H167V06), 74LVC16244
System address data bus
208
N.C
N.C
N.C
DM-1505
11  – 18
ChipsetASIC (VHIKZ4H167V06) I/O pin arrangement list (PCL Model)
PIN
No.
Pin name
Signal name
IN/OUT
Destination
Function
1
V
CC
3.3V
IN
Power source
2
SYSAD16
SYSAD16
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
3
SYSAD17
SYSAD17
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
4
SYSAD18
SYSAD18
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
5
SYSAD19
SYSAD19
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
6
SYSAD20
SYSAD20
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
7
SYSAD21
SYSAD21
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
8
SYSAD22
SYSAD22
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
9
V
CC
3.3V
IN
Power source
10
GND
GND
IN
GND
11
SYSAD23
SYSAD23
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
12
SYSAD24
SYSAD24
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
13
SYSAD25
SYSAD25
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
14
SYSAD26
SYSAD26
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
15
SYSAD27
SYSAD27
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
16
SYSAD28
SYSAD28
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
17
SYSAD29
SYSAD29
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
18
V
CC
3.3V
IN
Power source
19
GND
GND
IN
GND
20
SYSAD30
SYSAD30
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
21
SYSAD31
SYSAD31
IN/OUT
CPU, 16M FLASH, 8M FLASH
System address data bus
22
SYSAD32
SYSAD32
IN/OUT
CPU
System address data bus
23
SYSAD33
SYSAD33
IN/OUT
CPU, 74LVC16244
System address data bus
24
SYSAD34
SYSAD34
IN/OUT
CPU, 74LVC16244
System address data bus
25
SYSAD35
SYSAD35
IN/OUT
CPU, 74LVC16244
System address data bus
26
SYSAD36
SYSAD36
IN/OUT
CPU, 74LVC16244
System address data bus
27
V
CC
3.3V
IN
Power source
28
GND
GND
IN
GND
29
SYSAD37
SYSAD37
IN/OUT
CPU, 74LVC16244
System address data bus
30
SYSAD38
SYSAD38
IN/OUT
CPU, 74LVC16244
System address data bus
31
SYSAD39
SYSAD39
IN/OUT
CPU, 74LVC16244
System address data bus
32
SYSAD40
SYSAD40
IN/OUT
CPU, 74LVC16244
System address data bus
33
SYSAD41
SYSAD41
IN/OUT
CPU, 74LVC16244
System address data bus
34
SYSAD42
SYSAD42
IN/OUT
CPU, 74LVC16244
System address data bus
35
SYSAD43
SYSAD43
IN/OUT
CPU, 74LVC16244
System address data bus
36
GND
GND
IN
GND
37
GND
GND
IN
GND
38
GND
GND
IN
GND
39
V
CC
3.3V
IN
Power source
40
SYSAD44
SYSAD44
IN/OUT
CPU, 74LVC16244
System address data bus
41
SYSAD45
SYSAD45
IN/OUT
CPU, 74LVC16244
System address data bus
42
SYSAD46
SYSAD46
IN/OUT
CPU, 74LVC16244
System address data bus
43
SYSAD47
SYSAD47
IN/OUT
CPU, 74LVC16244
System address data bus
44
SYSAD48
SYSAD48
IN/OUT
CPU, 16M FLASH, 8M FLASH,
74LVC16244
System address data bus
45
SYSAD49
SYSAD49
IN/OUT
CPU, 74LVC244
System address data bus
46
SYSAD50
SYSAD50
IN/OUT
CPU, 74LVC244
System address data bus
DM-1505
11  – 19
Page of 127
Display