Document Systems Support
15
AR-M350/450
SIMULATION DATA
Perform Sim.22-06 Simulation Data Print
MAINTENANCE COMPLETED
Perform Sim. 24-04  Maintenance Counter Reset
Perform Sim.21-01  Maintenance Cycle Check
DEVELOPER REPLACEMENT
Perform Sim.  24-05  Dev Counter Reset
Perform Sim.  25-02  Developer Level Setting
DRUM REPLACEMENT
Perform Sim.  24-07  Drum Membrane Counter Reset
COPY QUALITY
Perform Sim. 46-02 Copy Quality Adjustment (Copy Mode)
SIMULATION DATA
Perform Sim.22-06  Simulation Data Print
AR-P350/450 AR-M350/450
 
   Technical Information Pack
Document Systems Support
16
AR-M350/450
Section
Adjustment Item
Adjustment
Procedure
Process
1
Developer doctor gap
.45mm
2
MG roller main pole position
54.2
3
Dev bias voltage
Sim 8-1
4
Main charger grid voltage
Sim 8-2
5
Transfer charge voltage
Sim 8-6
8
Toner concentration
Sim 25-2
Laser scanner
1
Horizontal image distortion
LSU lever adjustment
2
Print off centre
Sim 50-10
3
Laser power setting
Sim 61-20
Scanner
1
Vertical image distortion balance
Copy lamp unit installing
position
2
Vertical image distortion balance
No2/3 mirror base
installing position
3
Vertical image distortion
Winding pulley position
4
Horizontal image distortion
F rail height adjust
5
Main scan magnification ratio
CCD unit position
6
Main scan magnification ratio
Sim 48-1
7
Shading plate correction
Sim 46-17
8
Scanning image position
Sim 50-2
9
Original off center
Sim 50-12
Copy Density
1
Copy mode
Sim 46
Paper Feed
1
Manual bypass detection level
Sim 40-2
2
Paper size setting
Paper Transport
1
Separation Pawl Timing
Sim 51-1
2
Resist Roller Buckle
Sim 51-2
Others
1
2
3
Original size sensor detection level
Touch panel
Key touch sound volume
Sim 41-1 / 41-2
Sim 65-1
Sound volume adjustment
DSPF
1
2
Hinge height
Open/Close sensor position
Table clearance
Sim 2-2
AR-P350/450 AR-M350/450
 
   Technical Information Pack
Document Systems Support
17
7.
Test Commands  (AR-M350/450)
Simulation codes allow the copier engineer to test certain operations of the machine, and
also allow access to counter information and other operational variables. It is implemented to
assist the engineer in support of the product and it is important, therefore, that this mode of
operation is not be disclosed to users.
The key sequence required to enter the copier simulation mode is as follows :
P/#   -   * (ACC#-C)   -   C(Clear)   -   * (ACC#-C)
Once in simulation mode, a ‘main’ code and a ‘sub’ code relating to the required operation
must be entered :
Main Code   -   START Key   -   Sub Code   -   START Key
The operation of simulations in “Tiger” models is very similar to those utilized in “Cougar”.
There are differences so READ THE ON SCREEN INSTRUCTIONS CAREFULLY
AR-P350/450 AR-M350/450
 
   Technical Information Pack
Document Systems Support
18
AR-M350/450
Test
Command
Sub Code
Default
Setting
Description
1
--
Checks optical system.
01
Scanner test
02
Scanner sensor check
2
--
Checks Document Feeder ageing.
01
DF ageing test.
02
DF sensor check
03
DF output check (motor, clutch, solenoid)
3
--
Checks Finisher activation.
02
Finisher sensor check
03
Finisher output check (motor, clutch, solenoid)
06
Finisher jogger adjustment
10
Console Finisher adjustment (AR-FN7)
20
Mail bin stacker sensor check
21
Mail bin stacker load test
4
--
Checks Desk/LCT activation
02
Desk/LCT sensor check
03
Desk/LCT o/put check (motor, clutch, solenoid)
5
--
Checks the lighting of lamps.
01
LCD/LED test
02
Heater lamp check
03
Copy lamp check
6
--
Checks paper feed component activation
01
Paper feed o/put check (motor clutch solenoid)
02
Fan motor activation
7
--
Checks paper feed ageing
01
Paper feed ageing test setting
06
Interval ageing cycle timer set up
08
Warm up time display setting
8
--
Checks process voltages output.
01
Developer bias setting and output
02
MHV/Grid setting and output
06
THV check and adjust ( transfer).
17
THV setting and output
9
--
Checks ADU activation.
01
ADU output check (motor, clutch, solenoid)
02
ADU sensor check
Page of 58
Display

Click on the first or last page to see other AR-M35 / AR-M450 (serv.man40) service manuals if exist.