DOWNLOAD Sharp AR-M35 / AR-M450 (serv.man12) Service Manual ↓ Size: 7.51 MB | Pages: 112 in PDF or view online for FREE

Model
AR-M35 AR-M450 (serv.man12)
Pages
112
Size
7.51 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual Section 2 - Disassembly, Machine Operation, Adjustments, Simulations, Trouble Codes
File
ar-m35-ar-m450-sm12.pdf
Date

Sharp AR-M35 / AR-M450 (serv.man12) Service Manual ▷ View online

AR-M350 SIMULATIONS 10-2
8
1
Used to check and adjust the developing bias voltage in each 
print mode and its control circuit. 
Adjustment, 
operation test, check
Process (OPC drum, 
developing, transfer, 
cleaning)
2
Used to check and adjust the main charger grid voltage in each 
print mode and its control circuit. 
Adjustment, 
operation test, check
Process (OPC drum, 
developing, transfer, 
cleaning)
6
Used to check and adjust the transfer charger current and its 
control circuit. 
Adjustment, 
operation test, check
Process (OPC drum, 
developing, transfer, 
cleaning)
17
Used to set and check the transfer roller output. 
Operation test, check
Process (OPC drum, 
developing, transfer, 
cleaning)
Operation
9
1
Used to check the operation under load (clutches and 
solenoids) in the duplex section and their control circuits. 
Operation test, check
Duplex
Operation
2
Used to check the sensors and detectors in the duplex section 
and their control circuits. 
Operation test, check
Duplex
Operation
10
0
Used to check the operation of the toner motor and its control 
circuit. 
(Note) 
Do not execute this simulation with toner in the toner hopper. 
If executed, toner will enter the developing section, causing an 
overtoner trouble. Be sure to remove toner motor from the toner 
hopper before execution. 
Operation test, check
Process (OPC drum, 
developing, transfer, 
cleaning)
Operation
13
0
Used to cancel the self diag "U1" trouble. 
(Only when FAX is installed.)
Cancel 
(incase of a trouble)
Trouble
14
0
Used to cancel the self diag "U1/LCC/US/PF" troubles. 
Cancel 
(incase of a trouble)
Trouble
Error
15
0
Used to cancel the self diag "U6 (09/20/21/22)" trouble. 
Cancel 
(incase of a trouble)
Paper feed
Trouble
16
0
Used to cancel the self diag "U2" trouble. 
Cancel 
(incase of a trouble)
Trouble
Error
17
0
Used to cancel the self diag "PF" trouble 
(when copy is inhibited by the host computer).
Cancel 
(incase of a trouble)
Communication 
(RIC/MODEM)
Trouble
Error
21
1
Used to set the maintenance cycle. 
Setup
Spec
Counter
22
1
Used to check the print count in each section and in each 
operation mode. (Used to check the maintenance timing.)
Adjustment, setup, 
operation data output, 
check (display, print)
Counter
2
Used to check the number of total misfeed and troubles. 
(If the number of misfeed is considerably great, the machine 
must be repaired. The misfeed rate is obtained by dividing this 
count by the total counter value.)
Adjustment, setup, 
operation data output, 
check (display)
Trouble
3
Used to check the misfeed position and the number of misfeed 
at that position. 
(If the number of misfeed is considerably great, the machine 
must be repaired.) 
(Sections other than DSPF sections)
Adjustment, setup, 
operation data output, 
check (display)
Trouble
Misfeed
4
Used to check the total trouble (self diag) history.
Adjustment, setup, 
operation data output, 
check (display)
Trouble
5
Used to check the ROM version of each unit (section).
Other
Software
6
Used to print the list of adjustments and setup data 
(simulations, FAX soft switches, counters). 
Adjustment, setup, 
operation data output, 
check (print)
Data
Setup, 
adjustment 
data
7
Used to display the key operator code. 
(Used when the customer has forgotten the key operator code.)
Adjustment, setup, 
operation data output, 
check (display)
Data
User data
8
Used to check the number of use of the staple, DSPF, and 
scanner (reading) unit. 
Adjustment, setup, 
operation data output, 
check (display)
Counter
9
Used to check the number of use (print quantity) of each paper 
feed section.
Adjustment, setup, 
operation data output, 
check (display)
Paper feed
Counter
10
Used to check the system configuration 
(option, internal hardware). 
Adjustment, setup, 
operation data output, 
check (display)
Spec
Option
Code
Function (Content)
Purpose
Section
Item
Main Sub
 '     !"#$%&
AR-M350 SIMULATIONS 10-3
22
11
Used to check the use frequency of FAX. (send/receive)
(Only when FAX is installed.)
Adjustment, setup, 
operation data output, 
check (display)
FAX
Data
12
Used to check the misfeed position and the number of misfeed 
at that position. (If the number of misfeed is considerably great, 
the machine must be repaired.)
Adjustment, setup, 
operation data output, 
check (display)
DSPF
Trouble
Misfeed
13
Used to display the process cartridge data. 
Adjustment, setup, 
operation data output, 
check (display)
Counter
19
Used to display the scanner mode counter. 
Adjustment, setup, 
operation data output, 
check (display)
Counter
24
1
Used to clear the misfeed counter, misfeed history, trouble 
counter, and trouble history. (After completion of maintenance, 
these counters must be cleared.)
Data clear
Counter
2
Used to clear the number of use (print quantity) of each paper 
feed section. 
Data clear
Paper feed
Counter
3
Used to clear the number of use of the staple, ADF, RADF, SPF, 
DSPF, and the scanner (reading) unit. 
Data clear
Counter
4
Used to reset the maintenance counter.
Data clear
Counter
5
Used to reset the developer counter. 
(The developer counter of the DV unit installed is reset.)
Data clear
Process (OPC drum, 
developing, transfer, 
cleaning)
Counter
Developer 
(DV unit)
6
Used to reset the copy counter. 
Data clear
Counter
Copy
7
Used to clear the OPC drum counter and the toner cartridge 
counter. (Perform when the OPC drum is replaced.)
Data clear
Process (OPC drum, 
developing, transfer, 
cleaning)
Counter
OPC drum
9
Used to clear the printer print counter. (After completion of 
maintenance, this counter must be cleared.)
Data clear
Printer
Counter
Printer
10
Used to clear the FAX counter. (After completion of 
maintenance, this counter must be cleared.) 
(Only when FAX is installed.)
Data clear
FAX
Counter
11
Used to reset the drum rotation time, toner motor rotation time, 
and developer rotation time counters. 
The developer counter of the DV unit installed is reset.  
Data clear
Process (OPC drum, 
developing, transfer, 
cleaning)
Counter
Developer 
(DV unit)
15
Used to clear each counter in the scanner mode. 
Data clear
Counter
25
1
Used to check the operations of the main drive section 
(excluding the scanner (reading) section) and the toner density 
sensor. (The toner density sensor output can be monitored.)
Operation test, check
Drive
Operation
2
Used to initialize the toner density when replacing developer. 
(Auto adjustment)
Setup
Process (OPC drum, 
developing, transfer, 
cleaning)
26
3
Used to set the specification mode of the auditor. Setup must 
be made according to the use condition of the auditor.
Setup
Auditor
Spec
5
Used to set the count mode of the total counter and the 
maintenance counter. 
Setup
Spec
Counter
6
Used to set the specification according to the destination. 
Setup
Spec
Destination
10
Used to set the trial mode of the network scanner. 
Setup
Operation
18
Used to set Enable/Disable of toner save operation. 
(This simulation is enabled only in Japan and UK versions. 
(Depends on SIM 26-6 (Destination) setup). 
For the other destinations, user program P22 allows to make 
the similar setup.) 
Setup
Spec
Operation 
mode 
(Common 
operation)
30
Used to set the operation mode conforming to the CE mark 
(Europe standards). 
(For flickers when driving the fusing heater lamp.)
Setup
Spec
Operation 
mode 
(Common 
operation)
35
Used to set whether the trouble history of SIM 22-4 is displayed 
as one-time trouble or continuous troubles when two or more 
number of a same trouble occurred. 
Setup
Spec
38
Used to stop printing when developer life is expired.
Setup
Other
Operation
Code
Function (Content)
Purpose
Section
Item
Main Sub
      !"#$%&
AR-M350 SIMULATIONS 10-4
26
41
Used to set Enable/Disable of the magnification ratio auto 
selection function (AMS) in the pamphlet copy mode.
Setup
Spec
Operation 
mode 
(Common 
operation)
52
Used to set Enable/Disable of count-up when white paper is 
discharged. (White paper means the index paper 
(without copying) in the OHP index paper insertion mode, 
the front/rear covers  (without copying) in the cover insertion 
mode, and white paper in the duplex exit mode (CA, etc.).)  
Setup
Paper transport 
(Paper exit, 
switchback, transport)
27
1
Used to set the operation specifications when a communication 
trouble occurs between the host computer and MODEM 
(machine side). (When a communication trouble occurs 
between the host computer and MODEM (machine side), self 
diag display (U7-00) is displayed and setup is made to inhibit or 
allow printing. )
Setup
Communication 
(RIC/MODEM)
Spec
Operation 
mode 
(Common 
operation)
5
Used to enter the machine tag No. (This function allows to 
check the machine tag No. from the computer.)
Setup
Communication 
(RIC/MODEM)
Data
30
1
Used to check the operations of the sensors and detectors in 
the paper feed, paper transport, and paper exit sections and 
their control circuits. 
Operation test, check
Operation
2
Used to check the operations of the sensors and detectors in 
the paper feed section and their control circuits. 
(The operations of the sensors and detectors in the paper feed 
section can be monitored on the LCD display.)
Operation test, check
Paper feed
Operation
40
1
Used to check the operations of the manual paper feed tray 
paper size detectors and their control circuit. 
(The operations of the manual paper feed tray paper size 
detectors can be monitored on the LCD display.)
Operation test, check
Paper feed
Operation
2
Used to adjust the detection level of the manual paper feed tray 
paper width detector. 
Adjustment
Paper feed
Operation
7
Used to enter the adjustment value of the manual paper feed 
tray width detection level.
Adjustment, setup
Paper feed
Operation
11
Used to check the width detection level of the multi purpose 
tray paper width detector. 
Operation test, check
Paper feed
Operation
12
Used to adjust the width detection level of the multi purpose  
tray paper width detector. 
Adjustment, setup
Paper feed
Operation
41
1
Used to check the operations of the document size sensor and 
the related circuit. (The operation of the document size sensor 
can be monitored on the LCD display.)
Operation test, check
Other
Operation
2
Used to adjust the detection level of the document size sensor. Adjustment
Other
Operation
3
Used to check the operations of the document size sensor and 
the related circuit. (The output level of the document size 
sensor can be monitored on the LCD display.)
Operation test, check
Other
Operation
43
1
Used to set the fusing temperature in each operation mode. 
Setup
Fusing, paper exit
44
1
Used to set Enable/Disable of each correction operation in the 
image forming (process) section. 
Setup
Process (OPC drum, 
developing, transfer, 
cleaning)
Operation
4
Used to set the target image (reference) density level in the 
developing bias voltage correction. 
Setup
Process (OPC drum, 
developing, transfer, 
cleaning)
Data
9
Used to check the result (main charger grid voltage developing 
bias voltage, laser power, etc.) of correction 
(process correction) in the image forming section.
(By this simulation, the correction operation can be checked.)
Adjustment, setup, 
operation data output, 
check (display, print)
Process (OPC drum, 
developing, transfer, 
cleaning)
Data
Operation 
data 
(machine 
condition)
Code
Function (Content)
Purpose
Section
Item
Main Sub
 (     !"#$%&
AR-M350 SIMULATIONS 10-5
46
2
Used to adjust the copy density in the copy mode 
(binary, auto, text, text/photo, photo mode). 
An adjustment with this simulation affects all the copy density 
adjustment values.
Adjustment
Picture 
quality
Density
9
Used to adjust the print density for each density level 
(display value) in the copy mode (binary-Text mode). 
A desired print density can be set for each density level 
(display value). 
Adjustment
Picture 
quality
Density
10
Used to adjust the print density for each density level 
(display value) in the copy mode (binary-Text/Photo mode). 
A desired print density can be set for each density level 
(display value).
Adjustment
Picture 
quality
Density
11
Used to adjust the print density for each density level 
(display value) in the copy mode (binary-Photo mode). 
A desired print density can be set for each density level 
(display value).
Adjustment
Picture 
quality
12
Used to adjust the print density in the FAX mode (all modes). 
An adjustment with this simulation affects all the copy density 
adjustment values. (Only when FAX is installed)
Adjustment
Picture 
quality
13
Used to adjust the print density in the FAX mode 
(normal mode). (Only when FAX is installed.)
Adjustment
Picture 
quality
14
Used to adjust the print density in the FAX mode 
(small text mode). (Only when FAX is installed.)
Adjustment
Picture 
quality
15
Used to adjust the print density in the FAX mode (fine mode). 
(Only when FAX is installed.)
Adjustment
Picture 
quality
16
Used to adjust the print density in the FAX mode 
(super-fine mode). (Only when FAX is installed.)
Adjustment
Picture 
quality
17
Used to adjust the CCD/CIS shading reference value.
Setup, check
Picture 
quality
18
Used to adjust gamma (density gradient) in each copy mode. 
Adjustment
Picture 
quality
Density
19
Used to adjust gamma (density gradient) in the auto copy mode 
and to set the density detection area, and to set the image 
process mode. 
Adjustment
Picture 
quality
Density
20
Used to adjust the copy density correction in the SPF/DSPF 
copy mode for the document table copy mode. This adjustment 
is made so that the copy density becomes the same as that in 
the document table copy mode. 
Adjustment
Picture 
quality
Density
21
Used to adjust the scanner exposure level. 
(1 mode auto adjustment)
Adjustment, setup, 
operation data output, 
check (display)
Scanner (reading)
Picture 
quality
Density
22
Used to adjust the scanner exposure level and to make 
individual setup. (Normal mode)
Adjustment, setup, 
operation data output, 
check (display)
Scanner (reading)
Picture 
quality
Density
23
Used to adjust the scanner exposure level and to make 
individual setup. (Small text mode)
Adjustment, setup, 
operation data output, 
check (display)
Scanner (reading)
Picture 
quality
Density
24
Used to adjust the scanner exposure level and to make 
individual setup. (Fine mode)
Adjustment, setup, 
operation data output, 
check (display)
Scanner (reading)
Picture 
quality
Density
25
Used to adjust the scanner exposure level and to make 
individual setup. (Super fine mode)
Adjustment, setup, 
operation data output, 
check (display)
Scanner (reading)
Picture 
quality
Density
48
1
Used to adjust the copy magnification ratio 
(main scan direction, sub scan direction).
Adjustment
Scanner (reading)
Picture 
quality
5
Used to adjust the scan motor speed. 
Adjustment
Scanner (reading)
Picture 
quality
Code
Function (Content)
Purpose
Section
Item
Main Sub
 )     !"#$%&
Page of 112
Display