AR-M150/M155/M155X  TEST COMMAND, TROUBLE CODES  10 - 35
66
13
Dial test (Executable only 
when the FAX is installed.)
[Function]
Use to the dial test.
[Operation]
17
DTMF signal send (Max. 
value) (Executable only 
when the FAX is installed.)
[Function]
Use to set the DTMF signal send (Max. value).
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
 Dial test (PULSE)
1) Initial display
[CLEAR] key: FAX control is termi-
nated.
2) Select 1
3) Enter the make time in 2 digits.
XXXX: Default
After deleting with [CLEAR] key,
input can be made.
4) [OK (ENTER)] key
"yy" is the selected pulse 10 or 20.
"xx" is the input value.
Select 2: Returns to “2)” display.
5) Select 1
Switched to 10/20PPS set with
pulse selection inside.
6) After setting
7) After completion of sending
Select 2: Returns to “4)” display.
8) Select 1
After 2sec, returns to "1) Initial display".
SELECT SIGNAL
1:PULSE    2:DTMF
INPUT MAKE TIME
(0-15)            __
INPUT DIAL #
XXXX
SEND yyPPS xxms
1:YES 2:NO
SENDING yyPPS xxms
TERMINATE ?
1:YES 2:NO
TERMINATED
 Dial test (DTMF)
1) Initial display
[CLEAR] key: FAX control is terminated.
2)
Select 2
Select 2
3)
Select 1
Select 2
4) Select 1
XXXX: Default
After deleting with [CLEAR] key, input can be made.
4) [OK (ENTER)] key
"xx" indicates HI, and "yy" indicates Low Soft SW.
Select 2: Returns to “4)” display.
5) Select 1
HI/LO is selected with the signal level inside.
6) After setting the signal send level
7) After completion of sending
Select 2: Returns to “4)” display.
8) Select 1
After 2sec, returns to "1) Initial display".
SELECT SIGNAL
1:PULSE    2:DTMF
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15)            __
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15)            __
INPUT DIAL #
XXXX
H:xx        L:yy
1:YES 2:NO
SENDING DTMF
TERMINATE ?
1:YES 2:NO
TERMINATED
1) Initial display
[CLEAR] key: FAX control is terminated.
2) [10KEY] input
The content selected with signal send level
selection is set inside.
3) Communication is started after setting the
signal send level.
[CLEAR] key: Returns to "1) Initial display".
INPUT DIAL #
SENDING SIGNAL MAX
PRESS CLEAR TO STOP
AR-M150/M155/M155X  TEST COMMAND, TROUBLE CODES  10 - 36
66
18
DTMF signal send (Soft SW 
set value) (Executable only 
when the FAX is installed.)
[Function]
Use to set the DTMF signal send (Soft SW set value).
[Operation]
21
FAX information print 
(Executable only when the 
FAX is installed.)
[Function]
Use to print the FAX information.
[Operation]
24
FAST SRAM clear 
(Executable only when the 
FAX is installed.)
[Function]
Use to clear the FAST SRAM.
[Operation]
30
TEL/LIU status change 
check (Executable only 
when the FAX is installed.)
[Function]
Use to check the TEL/LIU status change.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
[CLEAR] key: FAX control is terminated.
2) [10KEY] input
The content selected with signal send level
selection is set inside.
3) Communication is started after setting the
signal send level.
[CLEAR] key: Returns to "1) Initial display".
INPUT DIAL #
SENDING SIGNAL SSW
PRESS CLEAR TO STOP
1) Initial display
2) [
/
] or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of 1 
 2 
 3 
1.
When [
] key is pressed, the sequence is reversed.
[CLEAR] key: FAX control is terminated.
3) [OK (ENTER)] key
• When print is allowed
After completion of printing,
FAX control is terminated.
• When print is inhibited
After 2sec, FAX control is 
terminated.
SELECT REPORT (1-3)
PRESS 
SELECT REPORT (1-3)
1:USER SW. LIST
SELECT REPORT (1-3)
2:SOFT SW. LIST
SELECT REPORT (1-3)
3:PROTOCOL
PRINT STORED
CAN NOT PRINT
1) Initial display
2) After completion of clearing
After 2sec, FAX control is terminated.
CLEAR FAST SRAM
CLEARED
1) Initial display
The display is switched every 2sec.
[CLEAR] key: FAX control is terminated.
HS2 :xxx  HS1 :xxx
RHS :xxx  EXHS:xxx
CHECKING
PRESS CLEAR TO STOP
AR-M150/M155/M155X  TEST COMMAND, TROUBLE CODES  10 - 37
66
32
Receive data check 
(Executable only when the 
FAX is installed.)
[Function]
Use to check the receive data.
[Operation]
33
Signal detection check 
(Executable only when the 
FAX is installed.)
[Function]
Use to check the signal detection.
[Operation]
34
Communication time 
measurement (Executable 
only when the FAX is 
installed.)
[Function]
Use to measurement the communication time.
[Operation]
37
Speaker sound volume 
setting (Executable only 
when the FAX is installed.)
[Function]
Use to set the speaker sound volume.
1: NO SOUND
2: LOW
3: MID
4: HIGH
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
2) After completion of reception
"xx" is "OK" or "NG" depending on the check
result. 
[CLEAR] key: FAX control is terminated.
RECEIVING
RESULT
            xx
1) Initial display
When a signal is detected, the display is changed from NONE to the following.
CI/CNG/CED/BT/DT/Flag/SDT/DTMF
[CLEAR] key: FAX control is terminated.
CHECKING        NONE
PRESS CLEAR TO STOP
1) Initial display
"xx:xx:xx:xxx" indicates o'clock, minute, second, millisecond.
[CLEAR] key: FAX control is terminated.
COMM. TIME
xx:xx:xx:xxx msec
1) Initial display
2) [
/
] or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of 1 
 2 
 3 
 1.
When [
] key is pressed, the sequence is reversed.
[CLEAR] key: FAX control is terminated.
3) [OK (ENTER)] key
xxx: Set content
After 2sec, FAX control is terminated.
SELECT SPEEKER VOL.
PRESS 
SELECT (1-4)
1:NO SOUND
SELECT (1-4)
2:LOW
.....
STORED
xxx
AR-M150/M155/M155X  TEST COMMAND, TROUBLE CODES  10 - 38
66
38
Time setting/check 
(Executable only when the 
FAX is installed.)
[Function]
Use to check the time setting.
[Operation]
41
CI signal check (Executable 
only when the FAX is 
installed.)
[Function]
Use to check the CI signal.
When CI signal is detected, OFF 
 ON.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
[CLEAR] key: FAX control is terminated.
2) Select 1
"xxxx.xx.xx(xxx)" is the current value. (No revi-
sion of display)
3)
Select 1
Select 2: Returns to "1) Initial display".
4) Enter the year in 4 digits.
5) Enter the month in 2 digits.
6) Enter the day in 2 digits.
"xxxx.xx.xx(xxx) is the entered value.
Select 2: Returns to "1) Initial display".
7) Select 1
After 2sec, returns to "1) Initial display".
2) Select 2
"xx:xx" is the current value.
3) Select 1
Select 2: Returns to "1) Initial display".
4) Enter o'clock in 2 digits.
5) Enter minute in 2 digits.
"xx:xx" is the current value.
Select 2: Returns to "1) Initial display".
6) Select 1
After 2sec, returns to "1) Initial display".
SELECT TO SET
1:DATE     2:TIME
xxxx.xx.xx(xxx)
CHANGE?   1:YES 2:NO
INPUT YEAR
(4 DIGITS)____.__.__
INPUT MONTH
(1-12)    1998.__.__
INPUT DAY
(1-31)    1998.01.__
xxxx.xx.xx(xxx)
STORED?   1:YES 2:NO
STORED
xx:xx
CHANGE?   1:YES 2:NO
INPUT HOUR
(0-24)         __:__
INPUT MINUTE
(00-59)        01:__
xx:xx
STORED?   1:YES 2:NO
STORED
1) Initial display
[CLEAR] key: FAX control is terminated.
CHECKING      CI:OFF
PRESS CLEAR TO STOP