DOWNLOAD Sharp AR-FX12 (serv.man7) Service Manual ↓ Size: 9.44 MB | Pages: 108 in PDF or view online for FREE

Model
AR-FX12 (serv.man7)
Pages
108
Size
9.44 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ARFX12 Service Manual
File
ar-fx12-sm7.pdf
Date

Sharp AR-FX12 (serv.man7) Service Manual ▷ View online

AR-FX12 MACHINE OPERATION 7-9
(3) Communication report sub code 
Report code 2
Content of communication interruption
Send/Receive
01
Send length over
Send
02
EOL time up
Receive
03
Carrier detection time up
Receive
04
Not used
-
05
Time up in phase C (8 min)
Send
06
Memory image decode error
Receive
07
Memory image decode error
Send
08
Time up between frames in phase C (Report code is 0 or 16.)
Send/Receive
09
Not used
-
10
Not used
-
11
Polarity reversion detection
Receive
12
Invalid command reception
Receive
13
Time up (1-minute timer/6-second time)
Receive
14
PUT error
Receive
15
In V.34 mode, time up is generated when shifting from Primary to Control.
Receive
16
In V.34 mode, time up is generated when shifting from Control to Primary.
Receive
17
Command receive time-up from MFP controller
Receive
18
Not used
-
19
Not used
-
20
Polarity reversion detection
Send
21
Invalid command reception
Send
22
Fallback retry number over
Send
23
Command retry number resend over
Send
24
Time up (T5 timer)
Send
25
Time up (T5 timer) in V.34 mode
Send
26
In V.34 mode, time up is generated when shifting from Primary to Control.
Send
27
In V.34 mode, time up is generated when shifting from Control to Primary.
Send
28
Modem chip response NG *1
Send/Receive
29
Not used
-
30
A communication error is generated between MFP controller and Modem controller. (Report code is 0 or 16.)
31
DC current not detected (busy)
Send
32
Dial tone not detected (busy)
Send
33
Busy tone detection (busy)
Send
34
T0 time up (Remote machine not responding)
Send
35
T1 time up (Remote machine not responding)
Send
36
In dialing, polarity reversion detection (Remote machine not responding)
Send
37
Calling is not made (busy)<Collision detected (including CNG detection)>
Send
38
JBIG chip response NG
Send/Receive
60
In resend of document filed data, an error occurs in decoding or coding.
61
In resend of document filed data, setting to inhibit resolution conversion is made. 
(The resolution after resend is set to be Enlarged.)
62
In resend of document filed data, rotation setting is made for data which cannot be rotated.
63
In resend of document filed data, data cannot be stored in HD after conversion of resolution for resend.
70
E-mail header acquisition error
71
Time out occurs during e-mail receive.
72
Receive reject occurs during e-mail receive.
73
Because of port disable, network communication is failed.
Network send
74
Authentication by the POP server is failed when POP before SMTP setting is valid.
Network send
80
There is no attached file in received e-mail.
81
The attached file of received e-mail is not of TIFF type which is supported.
82
The TIFF type of the attached file in received e-mail cannot be recognized. ID error
83
The TIFF type of the attached file in received e-mail cannot be recognized. Endian error
84
The TIFF type of the attached file in received e-mail cannot be recognized. Version error
85
The TIFF type of the attached file in received e-mail cannot be recognized. Tag data error
86
The TIFF type of the attached file in received e-mail cannot be recognized. Tag parameter error
87
The TIFF type of the attached file in received e-mail cannot be recognized. Header size error
88
The TIFF type of the attached file in received e-mail cannot be recognized. Data error
[07]MACHINEOPERATION.fm  9 ページ  2004年12月15日 水曜日 午後2時22分
AR-FX12 MACHINE OPERATION 7-10
*1: Does not occur in Tiger and Dragon.
When the sub code is 08 or 30, if the communication report is OK, the report code is 00 or 16. 
90
In e-mail receive, an attached file cannot be stored in memory. Memory overCannot be stored in memory.
91
In e-mail receive, an attached file cannot be stored in memory. The file size is too great to be stored in 
memory.
92
In SMTP e-mail receive, an attached file cannot be stored in memory. Cannot be stored in memory.
Report code 2
Content of communication interruption
Send/Receive
[07]MACHINEOPERATION.fm  10 ページ  2004年12月15日 水曜日 午後2時22分
AR-FX12 ELECTRICAL SECTION 8-1
[8] ELECTRICAL SECTION
1. Block Diagram
 32PIN
LEDX1
SP
CONNECTOR
CONNECTOR
POWER
CONNECTOR
RESET
circuit
NIGHT TIME FAX
POWER CONNECTOR
MODEM CIRCUIT
VOICE PATH
SWITCH CIRCUIT
SDRAM
(GA work memory)
TD62503
TEL/LIU
PWB UN
FAX
POWER
UNIT
CRYSTAL
OSCILLATOR
 14.7456MHz
VOLTAGE REGULATOR
(CPU POWER1.8V)
2PIN
/6PIN
SIGTX
RD/WR-,WATT,BS,WEO,WE1-
CS0-,CS2,CS4-,CS5-,IRQ3-CKIO
To FAX G/A
/3PIN
Crystal Oscilator
(12.3678MHz)
CRYSTAL
OSCILLATOR
(24.576MHz)
MFP controller
(FAX I/F PWB)
/
26PIN
ROM Emulator
I/F PWB
/
36PIN
PARTNER-ET II
(ROM Emulator)
H-UDI
connector
for emulator
SIGRX,SIGTX
HS1-,HS2-,RHS,CI-,CID-
EXHS-,CION,MR,SCML
DP,RCVMUTE-,MICMUTE-
VRSEL1-,VRSEL2-,VRSEL3-
EC,CID-,FNETD-,TELID
+5V(F),+12V(F),+12VS(F)
GND(DG),GND(AG)
To FAX G/A
From RESET circuit
From NIGHT TIME FAX circuit
From
NIGHT TIME FAX
circuit
To NIGHT TIME FAX circuit
RES_MFP-,F
AX_PWON
PRON_FAX-
CTS2,TXD2,RTS2,RXD2
CTS1,TXD1,RTS1,RXD1
FAX_VPP
To H-UDI CONNECTOR
for EMULATIONS
From
RESET
circuit
RESETP-
MWAIT-
CTS1,TXD1,RTS1
RXD1,CTS2,TXD2
RTS2,RXD2,FAX_RES-
RES_MFP-,MSW_OFF
VLED,FAX_VPP,CNCT_FAX-
FAX_PWON-,PRON_FAX-
DEBUG
MONITOR
CONNECTOR
FNETD-
RxD0,TxD0
PC for DEBUG
(DEBUG MONITOR TERMINAL)
/4PIN
+3.3(V),RxD0,TxD0,GND(DG)
BZ
SPSELA,SPELB,SPMUTE
VOLA
,VOLB
,VOLC
DP,S,CML,MR,RCVMUTE-,MICMUTE-,CION
EC,RHS,VRSEL1-,VRSEL2-,VRSEL3-
RESET1-,RESET
F-NETD-
CA[1:11]
CD[0:15]
IRQ0-
+5V(F)
+5V(F),+3.3 (F),+12V(F),GND(DG),GND(AG)
+12VS(F),GND(AGS),DCPR
RESET1-
VLED
MSW_OFF
For DEBUGGING(No memory)
Address BUS
Data BUS
FAX_RES-
MANRES-
CNCT_FAX-
F-NETD-
SDRAM
(CPU WORK 
MOMORY)
FLASH MEMORY
(PROGRAMU ROM)
CA[2:15]
CD[0:31]
CD[0:31]
CA[2:22]
IORES2-
MODEM
(DSP)
To FAX G/A,SERIAL
EEPROM
CS0-,RD-,WE0-
RESET
RESET-
RESET
RESET
From
RESET circuit
Connect 
the ROM socket
SCIF2
RS-232
Transceiver
RS-232
Transceiver
MFP-I/F
connector
(All Signal)
CI-
MODEM
(AFE)
DCPR
FAX G/A
TEL/LIU
CONNECTOR
CS3-,RD/WE,CKIO,CKE
RAS3L-,CASL-,
WE0-,WE1-,WE2-,WE3-
1.8V generation
LEDX1
Serial
EEPROM
CPU
ROM_VPP
ROM_VPP
To CPU
From INVERTER
MWAIT
From FAX G/A
Frequency
diffusion
RESET-
MSW_OFF2
Inverter
PRON_FAX
+5VS(F)
FAX_PWON
PRON_FAX
To TD62503F
NIGHT TIME
FAX
CIRCUIT
PICVPP
PICCK
PICDI
PICDO
PICRES-
To CPU
From CPU
To CPU
+5V(F)
3.3V generation
3-PIN REGULATOR
 (NIGHT TIME FAX POWER 5V)
+12VS(F)
5VS generation
3-PIN REGULATOR
(MODEM POWER 3.3V)
TPW1,2:
Power ON mode
Select pin
I pattern
MONITOR
CIRCUIT
I pattern
MONITOR
CONNECTOR
4PIN
CID-
FAXVPP
From MFPI/F CONNECTOR
FNETON-
CD[0:15]
CA[1:23]
From FAX G/A
From FAX G/A
From FAX G/A
From FAX G/A
SIGTX
IORES-
CS5-,RD
IOWR0-,IOWR1-
[08]ELECTRICALSECTION.fm  1 ページ  2004年12月15日 水曜日 午後2時22分
AR-FX12 ELECTRICAL SECTION 8-2
2.Actual Wiring Diagram
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
CN6
30FE-BT-VK-N
DG
AG
AG
SIGRX
TELRX
SIGTX
+12V(F)
+12V(F)
HS1-
HS2-
RHS
EXHS-
CI-
CION
MR
S
CML
DP
RCVMUTE-
MICMUTE-
VRSEL1-
VRSEL2-
VRSEL3-
EC
CID-
FNETD-
+5V(F)
+12VS(F)
AGS
DG
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
1
9
8
7
6
5
4
3
2
26
25
CN1
DX10G1M-26SE
DG
FAX_RXD1
FAX_TXD1
FAX_CTS1
FAX_RTS1
FAX_RXD0
FAX_TXD0
FAX_CTS0
FAX_RTS0
FAX_RES-
PRON_FAX-
VLED
FAX_VPP
DG
DG
DG
DG
DG
DG
DG
DG
DG
RES_MFP-
MSW_OFF
CNCT_FAX-
FAX_PWON-
1
3
2
+12VS(F)
DCPR
AGS
CN7
B3B-PH-K-S
1
6
5
4
3
2
(NC)
+3.3V(F)
DG
+5V(F)
AG
+12V(F)
MDMC PWB
CN5
B2B-PH-K-S
1
2
SP-
SP+
-
+
OR
BR
GY
GY
BL
GY
BR
OR
OR
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
1
9
8
7
6
5
4
3
2
30
29
28
27
26
25
30FE-BT-VK-N
DG
AG
AG
SIGRX
TELRX
SIGTX
HS1-
HS2-
RHS
EXHS-
CI-
CION
MR
S
CML
RCVMUTE-
MICMUTE-
VRSEL1-
VRSEL2-
VRSEL3-
EC
CID-
FNETD-
AGS
DG
DG
AG
AG
SIGRX
SIGTX
HS1-
HS2-
CI-
S
CML
VRSEL1-
VRSEL2-
VRSEL3-
CID-
DG
(NC)
LIUID
(NC)
(NC)
DPMUTE
DP-
(NC)
(NC)
(NC)
(NC)
(NC)
4
3
2
1
4
3
2
1
5
6
CN1
MD-S610-90
TX+
RX+
RX-
TX-
RHS-
DG
5
6
12V
12V
12V
12V
5V
5V
12VS
12VS
1
2
CN2
(JPN/UC)
CN1
(EU/AUS)
MJ2
BT2
LT2
TEL2
TEL1
BT1
LT1
CN3
S03B-XASK-1
JPN Only
CIP
AG
CIOUT-
1
3
2
TEL/LIU PWB
JPN Only
CIP
AG
CIOUT-
1
3
2
SMP-03V-NC
1
3
2
CIP
AG
CIOUT-
SMR-03V-N
BR
GY
BR
BR
GY
PL
BR
GY
PL
B6P-VH
B3B-PH-K-S
1
3
2
DCPR
1
6
5
4
3
2
+12VL
GND-S
+12V
GND(AG)
+5V
GND(DG)
+3.3V
FW
CN2
CN1
1
3
2
CN3
S04B-XASK-1
4
CIP
(NC)
GND(AG)
CIOUT-
FAX POWER un
L
N
N1F
L1F
GY
BL
GY
BR
WH(BL)
BK(BR)
WH(BL)
BK(BR)
GR/YL(GR/YL)
GR/YL(GR/YL)
OR
OR
OR
BR
GY
BR
BR
GY
FG(Earth)
Lout
Nin
FG(Earth)
Lin
Nout
6
5
4
3
2
1
WH(BL)
BK(BR)
WH(BL)
BK(BR)
VLP-06V-1
100V(200V)
GR/YL(GR/YL)
GR/YL(GR/YL)
to
MAIN un
SPEAKER
un
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
10
20
11
12
14
13
15
16
17
18
19
21
22
23
24
25
26
27
28
29
30
40
31
32
33
34
35
36
37
38
39
50
41
42
43
44
45
46
47
48
49
60
51
52
53
54
55
56
57
58
59
70
61
62
63
64
65
66
67
68
69
80
71
72
73
74
75
76
77
78
79
90
81
82
83
84
85
86
87
88
89
100
91
92
93
94
95
96
97
98
99
2
1
3
4
5
6
7
8
9
100R2.8-JXKS-GB
CN3
to
MFP
Control
Unit
100V Only
T2
FG
FG
1
2
3
4
T1
T2
L1
L2
L1
L2
to LINE
to EXTENSION PHONE
1
2
T1
(EU/AUS)
(JPN/UC)
MJ-62J-RD315
MJ-64J-RD315
MJ1
(EU/AUS)
(JPN/UC)
MJ-62J-RD315
MJ-64J-RD315
DG
PRON_FAX-
DG
DG
DG
DG
DG
DG
DG
DG
DG
RES_MFP-
CNCT_FAX-
FAX_PWON-
CN-1
DX10G1M-26SE
TXD0
RXD0
RTS0
CTS0
TXD1
RXD1
RTS1
CTS1
FRDY
FFVPPW
MSW_MON-
CN8
B6P-VH
DP-
BL
RD
BL
RD
RES_FAX-
FXA7
FXA8
FXA9
FXA10
FXA11
FXA12
FXA13
FXA14
FXA15
FXA16
FXA17
FXA18
FXA19
FXA20
RES_MFP-
FXA6
FXA5
FXA21
FXA4
FXA3
FXA2
DG
DG
DG
DG
FXD31
FXD30
FXD29
FXD28
FXD27
FXD25
FXD24
FXD23
FXD22
FXD21
FXD20
FXD19
FXD18
FXD17
FXD16
FXD15
FXD14
FXD13
FXD12
FXD11
FXD10
FXD9
FXD8
FXD7
FXD6
FXD5
FXD4
FXD3
FXD2
FXD1
FXD0
DG
DG
(NC)
DG
DG
(NC)
FMCS15
FMCS16
FXA22
FOE2
FWE2
(NC)
DTXD0
DRTS0
DRXD0
DCTS0
RES_FAX-
CTXD1
CRTS1
CRXD1
CCTS1
CNCT_FAX
(NC)
(NC)
FRDY
MSW_MON-
RD/BY-
FRESET
FB_IN
FAX_PWON-
DG
PRON_FAX-
DG
+5V
+5V
+5V
FX_VCCW
+3.3V
+3.3V
+3.3V
+3.3V
DG
DG
FXD26
FAX I/F PWB
[08]ELECTRICALSECTION.fm  2 ページ  2004年12月15日 水曜日 午後2時22分
Page of 108
Display