Sharp AR-FN1 (serv.man7) Service Manual ▷ View online

[Precaution in setting]
1) Insert the solenoid pin B through the slot A in the paper feed lever,
insert the shaft C through the D-cut hole in the paper feed lever,
and secure the solenoid with the screw 4). In this step, align the
edge of the gate solenoid installation plate with the position align-
ing stamp as shown in the enlargement below. 
4. Paper discharge gate solenoid 1
7)
4)
5)
6)
A
B
C
4)
Positioning marks
2)
1)
3)
2)
2)
1)
2)
7)
4)
5)
6)
6 – 3
[Adjustment and precaution in setting]
1) Insert the solenoid pin A through the longer slot in the valve
moving arm B shown in the figure below and secure with the
screw 4). In this step, align the edge of the solenoid installation
plate 6) with the position aligning stamp as shown in the enlarge-
ment.
2) Hook one end of the paper discharge solenoid spring C in the
smaller slot in the valve moving arm B and the other end in the
hole in the F flame.
5. Paper discharge gate solenoid 2
[Adjustment and precaution in setting] 
1) Insert the solenoid pin A through the longer slot in the paper
discharge gate 2 B and secure with the screw 4). In this step, the
solenoid installation plate 6) is positioned as shown in the enlarge-
ment below.
B A
C
4)
6)
Positioning lines
Match the right-most with the
middle of the second.
1)
2)
2)
3)
7)
4)
5)
6)
B
4)
A
Positioning mark
6 – 4
6. Paper discharge gate solenoid 3
[Adjustment and precaution in setting]
1) Insert the solenoid pin B through the notch in the manual stopper
rotation arm A and secure with the screw 4). In this step, align the
edge of the solenoid installation plate 6) with the positioning line at
the center.
7. Short path switching solenoid
1)
2)
2)
3)
7)
4)
5)
6)
B
4)
A
2)
1)
3)
4)
3)
3)
3)
11)
10)
6 – 5
8. Tray 3 upper limit solenoid 
Slide the upper limit sensor unit 2) in the direction indicated by the
arrow and remove it.
[Adjustment and precautions in setting]
1) Adjust the distance from the end A of the installation plate 6) to
the actuator B for 8 mm, with the solenoid fully pulled. Secure the
solenoid with the screw 4).
2) Use caution to align the notch C of the upper limit sensor unit 2
with the notch D of the rear edge reinforcement plate when secur-
ing the upper limit sensor unit 2 with the screw 1). (See the figure
below.)
P
1)
2)
3)
4)
5)
6)
As a rough guide, screw so
that the edges of solenoid
mounting plate 6) are
matched.
Line
A
B
4)
8mm
D
C
6)
6 – 6