AR-C330 EXTERNAL VIEW AND INTERNAL STRUCTURE 5 - 34
(9) Fuses, thermostat
No.
Parts
Note
Code
Name
Type
Spec
Function/Operation
1
F1
Scanner motor
power fuse
power fuse
Normal fuse
Protects the scanner motor and its
control circuit from an overcurrent.
control circuit from an overcurrent.
Scanner motor
control PWB
control PWB
2
HLTSU
Upper heat roller
thermostat
thermostat
Thermostat
Cuts conduction to the heater lamp
when the temperature rises abnormally.
when the temperature rises abnormally.
Fusing unit
3
HLTSD
Lower heat roller
thermostat
thermostat
Thermostat
Cuts conduction to the heater lamp
when the temperature rises abnormally.
when the temperature rises abnormally.
Fusing unit
5
F701
Scanner lamp
power fuse
power fuse
Normal fuse
250V 4A
Protects the scanner lamp from an
overcurrent.
overcurrent.
Scanner lamp
control PWB
control PWB
6/7
F102/F101
AC main power
primary side fuse
primary side fuse
Normal fuse
250V 15A
Protect the AC main power primary side
from an overcurrent.
from an overcurrent.
100V series
AC main power
primary side fuse
primary side fuse
Normal fuse
240V 10A
Protect the AC main power primary side
from an overcurrent.
from an overcurrent.
200V series
8
F706
DC power
primary side fuse
primary side fuse
Normal fuse
250V 6.3A
Protect the DC power primary side from
an overcurrent.
an overcurrent.
200V series
9
F2
DC main power
+24V
+24V
Normal fuse
125V 6.3A
Overcurrent protection of the LSU, the
OPC drum motor, the RADF, the
finisher, the PCU MAIN PWB, the paper
feed/transport section motors
OPC drum motor, the RADF, the
finisher, the PCU MAIN PWB, the paper
feed/transport section motors
100V series
F701
DC main power
+24V
+24V
Normal fuse
250V 6.3A
200V series
10
F3
DC main power
+24V
+24V
Normal fuse
125V 4.0A
Overcurrent protection of the PCU SUB
PWB, the transfer belt section motor,
the fusing motor, the developing motor
(color), the CD power PWB, and the
high voltage (TC) PWB
PWB, the transfer belt section motor,
the fusing motor, the developing motor
(color), the CD power PWB, and the
high voltage (TC) PWB
100V series
F702
DC main power
+24V
+24V
Normal fuse
250V 6.3A
200V series
1
2
3
5
100V
200V
9
10
11
8
9
6/7
10
11
12
AR-C330 EXTERNAL VIEW AND INTERNAL STRUCTURE 5 - 35
(10) Power source
11
F4
DC main power
+24V
+24V
Normal fuse
125V 4.0A
Overcurrent protection of the developing
motor (black), the high voltage (MC, DV)
PWB, the LCC, the scanner motor, the
operation PWB, the ADU, and the
printer controller
motor (black), the high voltage (MC, DV)
PWB, the LCC, the scanner motor, the
operation PWB, the ADU, and the
printer controller
100V series
F703
DC main power
+24V
+24V
Normal fuse
250V 4A
200V series
12
Scanner lamp
temperature fuse
temperature fuse
Temperature
fuse
fuse
104°C 250V
10A
10A
Cuts conduction to the scanner lamp
when the temperature rises abnormally.
when the temperature rises abnormally.
No.
Parts
Note
Name
Function/Operation
Spec
1
CCD power PWB
Outputs the CCD PWB power.
2
High voltage power
PWB (TC)
PWB (TC)
Generates the transfer voltage.
3
Fusing control PWB
(AC sub PWB)
(AC sub PWB)
Interfaces the heater lamp drive control, the sensor, and the detector
signals.
signals.
4
DC main power
PWB
PWB
Generates a voltage used by the other unit than the operation unit.
5
AC main power
PWB
PWB
Controls the power (AC power) on the primary side.
6
High voltage power
PB (MC/DV)
PB (MC/DV)
Generates the high voltage for the main charger and the developing
bias voltage.
bias voltage.
No.
Parts
Note
Code
Name
Type
Spec
Function/Operation
1
2
3
4
5
6
AR-C330 EXTERNAL VIEW AND INTERNAL STRUCTURE 5 - 36
(11) Adjustment volumes
(12) Lock positions
No.
Parts
Note
Code
Name
Function/Operation
1
RV2 (100V series)
+3.4V power voltage adjustment volume
Adjusts the +3.4V power voltage.
DC power PWB
2
VR702 (200V series)
+5V power voltage adjustment volume
Adjusts the +5Vpower voltage. (200V series)
DC power PWB
3
VR701 (200V series)
+3.4V power voltage adjustment volume
Adjusts the +3.4V power voltage.
DC power PWB
2
4
4
5
1
3
AR-C330 EXTERNAL VIEW AND INTERNAL STRUCTURE 5 - 37
(13) ADU section
No.
Parts
Note
Name
Function/Operation
1
Scanner lock screw
Locks the scanner. (Prevents the scanner from moving in transit.)
Be sure to
lock in transit.
lock in transit.
2
Transfer unit lock screw
Locks the transfer unit. (Prevents the transfer unit from moving in transit.)
3
Paper tray lock block
Locks the paper lift plate.
4
Fusing, transfer unit lock screw
Locks the fusing, transfer unit. (Prevents the transfer unit from projecting in
transit.)
transit.)
5
Paper guide lock screw
Locks the paper guide.
No.
Code
Name
Type
Function and operation
1
DPPD1
Transport sensor 1
Photosensor
ADU paper-in sensor
2
DPPD2
Transport sensor 2
Photosensor
ADU transport sensor
3
DPPD3
Transport sensor 3
Photosensor
ADU reverse sensor
4
DPHPS
Alignment home
position sensor
position sensor
Photosensor
Alignment plate home position detection
5
DMRE
Transport motor
encoder
encoder
Photosensor
Transport motor speed control sensor
6
DDM
Transport motor
DC motor
ADU transport roller, decurler unit transport roller driver from the
coupler pulley
coupler pulley
7
PAM
Alignment motor
Stepping motor
Alignment guide drive
8
DRM
Reverse motor
Stepping motor
Reverse roller drive for paper feed and paper exit for reverse section
9
DPRS
Reverse roller
solenoid
solenoid
Solenoid
Reverse roller pressure release for paper exiting to the copier or for
alignment
alignment
10
DTD
Decurler sensor
Photosensor
Transport sensor for decurler unit
11
ADUSW
ADU switch
Microswitch
Turn ON/OFF the +24V supplied to the ADU main PCB for removal and
installation of the ADU
installation of the ADU
12
DDSW
Decurler switch
Microswitch
Turn ON/OFF the +24V supplied to the ADU main PCB for opening and
closing of the decurler doors
closing of the decurler doors
13
DPFC
Transport clutch
Electromagnetic
clutch
clutch
Turn ON/OFF the power for the transport roller
14
DTC1
Decurler clutch
Electromagnetic
clutch
clutch
Switch between normal and double speed for the decurler unit
transporting
transporting
15
BEAR ADU PCB
PC board
Control of ADU unit
16
Motor relay board
PC board
Relay board
5
1
6
16
13
4
15
11
8
3
2
7
9
12
14
10
Click on the first or last page to see other AR-C330 (serv.man5) service manuals if exist.