Sharp AR-C330 (serv.man5) Service Manual ▷ View online
AR-C330 SETTING AND ADJUSTMENTS 7 - 42
This adjustment must be performed in the following cases:
• When the manual paper feed tray section is disassembled.
• When the manual paper feed tray is replaced.
• When a U2 trouble occurs.
• When the PCU main PWB is replaced.
• When the EEPROM of the PCU main PWB is replaced.
1) Execute SIM 40-2.
2) Extend the manual paper feed guide fully.
3) Press [MAX POSITION] on the LCD of the operation panel to
highlight it.
4) Press [EXECUTE] on the LCD of the operation panel to high-
light it.If normal, the highlight is shifted from [MAX POSITION]
to [MIN POSITION].
to [MIN POSITION].
5) Narrow the manual paper feed tray guide fully.
6) Press [EXECUTE] on the LCD of the operation panel to high-
light it.
Check that [COMPLETE] is highlighted.
This adjustment must be performed in the following cases:
• When the OHP sensor is replaced.
• When the OHP sensor is disassembled.
• When a U2 trouble occurs.
• When the PCU main PWB is replaced.
• When the EEPROM of the PCU main PWB is replaced.
1) Enter the SIM 40-5 mode.
2) Set A4 (11 x 8.5) paper to the manual paper feed tray.
3) Press the EXECUTE key.
Paper in the manual paper feed tray is fed and stopped at the
OHP sensor section.
OHP sensor section.
The sensor LED current level is automatically adjusted so that the
specified (target) output of the OHP sensor is supplied.
specified (target) output of the OHP sensor is supplied.
After adjustment, paper is discharged and the result data is dis-
played.
played.
When the adjustment is completed normally, ADJUSTMENT
COMPLETE is displayed. When an error occurs, ADJUSTMENT
ERROR is displayed.
COMPLETE is displayed. When an error occurs, ADJUSTMENT
ERROR is displayed.
ADJ M24
Manual paper feed size detection
level adjustment
level adjustment
ADJ M25
OHP sensor adjustment
AR-C330 SIMULATION 8 - 1
[8] SIMULATION
(Diagnostics, setting, adjustment value
input, data display)
input, data display)
1. Outline and purpose
There are the following simulation functions to check the machine
operations, troubleshoot, find causes, make various settings,
improves adjustment work speeds and serviceability.
operations, troubleshoot, find causes, make various settings,
improves adjustment work speeds and serviceability.
1) Various adjustments
2) Specification and function setting
3) Trouble cancel
4) Operation check
5) Counters check, setting, clear
6) Machine operation conditions (operation history) data check,
clear
7) Transmission of various data (adjustment, setting, operations,
counter, etc.)
The operating procedures and displays slightly differ from the form
of the machine operation panel.
of the machine operation panel.
The typical forms are as follows:
1) Code system: Values input and mode selection are made with
the 10-key pad and various function keys.
2) Switch system: Simulation mode selection is made by combi-
nation of switch setting.
3) Values and mode selection is made with various function keys.
As a special one, a jumper wire is used to connect the check
points on the PWB to select the desired mode.
points on the PWB to select the desired mode.
2. Code system simulation
A. Operating procedures and operations
∗
Entering the simulation mode
1) Program (P) key
→
Interrupt key
→
Clear key
→
Interrupt key
(The machine enters the standby mode for the simulation main
code.)
code.)
2) Enter the main code with 10-key pad.
→
Press START key.
3) Enter the sub code of with 10-keypad.
→
Press START key.
4) Select the mode and the item with the 10-key pad and the
function key.
5) The machine enters the selected mode.
To start the simulation, press the START key or the function
key.
key.
To cancel the current simulation mode and to change the main
code and the sub code, press the interrupt key.
code and the sub code, press the interrupt key.
1) Press the all clear key.
∗
The simulation mode is canceled and the machine returns to the
normal operation mode.
normal operation mode.
AR-C330 SIMULATION 8 - 2
YES
NO
NO
YES
YES
YES
NO
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
NO
Standby for entry of SIM
sub code
Enter SIM sub code with
the 10-key.
Press the START button.
Press the START button.
The display is made according
to the selected mode and the item.
START (Normal mode)
Press the Program (P) key.
Press the interrupt key.
Press the clear key.
Press the interrupt key.
Standby for entry of
SIM code.
Enter the main code of
SIM with the 10-key.
The main code of SIM
is displayed.
Press the START button.
Is there a sub code ?
Select the mode and the
item with the 10-key and
item with the 10-key and
the function key.
Operation check ?
Operating conditions
check ?
Data clear ?
Adjustments
or setting (counter data
change) ?
Do you
want to change the
content ?
Enter the new setting and
adjustment values.
Press the interrupt key.
Press the START button.
Operation is made according
to the selected mode and item.
Press the START button.
The display is made according to
the selected some and the item.
Press the START button.
Press the START button.
Is it the same
simulation ?
Press the interrupt key.
Do you want
to perform another
simulation ?
Do you
want to end the
simulation ?
The changed content
is stored.
The simulation mode
is canceled.
Press the clear all key.
Operation is made according
to the selected mode and the item.
(Other modes)
The selected mode and
the item are cleared.
AR-C330 SIMULATION 8 - 3
B. Simulation list
(1) Main/Sub
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
1
1
Used to check the operations of the
scanner unit and its control circuit.
scanner unit and its control circuit.
Operation test/check
Optical (Image scanning)
Operation
2
Used to check the sensors and
detectors in the scanner section and
the related circuits.
detectors in the scanner section and
the related circuits.
Operation test/check
Optical (Image scanning)
Operation
2
1
Used to check the operations of the
RADF unit and the control circuit. (The
document feed operation is repeatedly
performed.)
RADF unit and the control circuit. (The
document feed operation is repeatedly
performed.)
Operation test/check
RADF
Operation
2
Used to check the operations of the
sensors and detectors in the RADF unit
and the related circuits.
sensors and detectors in the RADF unit
and the related circuits.
Operation test/check
RADF
Operation
3
Used to check the operations of the
loads in the RADF unit and the related
circuits.
loads in the RADF unit and the related
circuits.
Operation test/check
RADF
Operation
3
2
Used to check the operations of the loads
in the sorter/finisher and the related
circuits.
in the sorter/finisher and the related
circuits.
Operation test/check
Sorter/Finisher
Operation
3
Used to check the operations of the loads
in the sorter/finisher and the related
circuits.
in the sorter/finisher and the related
circuits.
Operation test/check
Sorter/Finisher
Operation
4
2
Used to check the operations of the
sensors and detectors in the large
capacity tray and the related circuit.
sensors and detectors in the large
capacity tray and the related circuit.
Operation test/check
Paper transport
Operation
3
Used to check the operations of the loads
in the large capacity tray and the control
circuit.
in the large capacity tray and the control
circuit.
Operation test/check
Paper transport
Operation
5
1
Used to check the operations of the
operation panel display lamps and LCD
and the control circuit.
operation panel display lamps and LCD
and the control circuit.
Operation test/check
Operation (Display/
Operation key)
Operation key)
Operation
2
Used to check the operations of the
heater lamp and the control circuit.
heater lamp and the control circuit.
Operation test/check
Fixing (Fusing)
Operation
3
Used to check the operations of the
scanner lamp and the control circuit.
scanner lamp and the control circuit.
Operation test/check
Optical (Image scanning)
Operation
4
Used to check the operations of the
discharge lamp and the control circuit.
discharge lamp and the control circuit.
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
(Photoconductor/
Developing/Transfer/
Cleaning)
Others
Operation
6
1
Used to check the operations of the loads
(clutches and solenoids) in the paper
transport system and the control circuits.
(clutches and solenoids) in the paper
transport system and the control circuits.
Operation test/check
Paper transport
(Discharge/Switchback/
Transport)
(Discharge/Switchback/
Transport)
Operation
2
Used to check the operation of each
fan motor and its control circuit.
fan motor and its control circuit.
Operation test/check
Others
Operation
7
1
Used to set the aging conditions.
Setting/Operation test/
check
check
Operation
6
Used to set the intermittent aging
cycle.
cycle.
Setting/Operation test/
check
check
Operation
8
Used to set Yes/No of warm-up time
display.
display.
Setting/Operation test/
check
check
Operation
9
Used to check the operation of each
color image quality.
color image quality.
Operation test/check
Others
Picture quality
8
1
Used to check and adjust the operation
of each print mode developing bias
voltage and the control circuit.
of each print mode developing bias
voltage and the control circuit.
Adjustment/Operation
test/check
test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
(Photoconductor/
Developing/Transfer/
Cleaning)
2
Used to check and adjust the operation
of each print mode main charger grid
voltage and the control circuit.
of each print mode main charger grid
voltage and the control circuit.
Adjustment/Operation
test/check
test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
(Photoconductor/
Developing/Transfer/
Cleaning)
9
1
Used to check the operation of the
loads (clutches and solenoids) in the
duplex section and the control circuit.
loads (clutches and solenoids) in the
duplex section and the control circuit.
Operation test/check
Duplex
Operation
2
Used to check the operation of the
sensors and detectors in the duplex
section and the control circuit.
sensors and detectors in the duplex
section and the control circuit.
Operation test/check
Duplex
Operation
4
Used to check the operation of the
duplex unit alignment plate and the
control circuit.
duplex unit alignment plate and the
control circuit.
Operation test/check
Duplex
Operation
Click on the first or last page to see other AR-C330 (serv.man5) service manuals if exist.