PDF
Document
User Manual / Operation Manual
Brand
Device
Copying Equipment / AR-C260 Key Operators guide
File
ar-c260-sm33.pdf
Date

Sharp AR-C260 (serv.man33) User Manual / Operation Manual ▷ View online

9
GENERAL PROGRAMS
■ Device control
These programs are used to enable or disable the
use of a peripheral device.
Original size detector setting
This program is used to select the group of original
sizes to be detected. Original size detection from
the document glass can be disabled using the
program CANCEL DETECTION AT DOCUMENT
GLASS.
If CANCEL DETECTION AT DOCUMENT GLASS
is set, originals will be regarded as EXTRA for all
copier functions and no original size will be
displayed.
Disabling of document feeder
This program is used to prevent use of the
reversing automatic document feeder when it
malfunctions. In this case, scanning can still be
performed using the document glass.
Disabling of duplex
This program is used to disable duplex printing
when the duplex module malfunctions. If this
program is set, only one-sided printing can be
performed.
Disabling of inverter
Use this program when you need to prohibit the
inverter function or when the duplex bypass/
inverter unit has failed. When the program is turned
on, pages are only output face-down to the centre
tray of the machine. Duplex printing is also not
possible (only one-sided printing is possible).
Disabling of stapler
This program is used to disable stapling when the
stapler unit of the saddle stitch finisher
malfunctions.
Disabling of optional paper drawer
This program is used to disable use of the stand/1
x 500 sheet paper drawer, stand/3 x 500 sheet
paper drawer or duplex module/2 x 500 sheet
paper drawer when it malfunctions.
Disabling of shifter
Use this program when you need to prohibit the
shifter function in the centre tray or when the shifter
has failed. When the program is turned on, the
offset feature that offsets sets of copies or printed
pages in the centre tray will not function.
Disabling of finisher
This program is used to disable use of the saddle
stitch finisher when it malfunctions.
Group
Detectable original sizes
Document feeder tray (for reversing
automatic document feeding)
Document glass
1
INCH - 1
11" x 17", 8-1/2" x 14",
8-1/2" x 11", 
8-1/2" x 11"R,
5-1/2" x 8-1/2"
A3, B4, A4,
B5, B5R
2
INCH - 2
11" x 17", 8-1/2" x 13",
8-1/2" x 11", 
8-1/2" x 11"R,
5-1/2" x 8-1/2"
A3, B4, A4,
B5, B5R
3
AB - 1
A3, A4, A4R, A5,
B4, B5, B5R
11" x 17", 8-1/2" x 14",
8-1/2" x 11"
4
AB - 2
A3, A4, A4R, A5,
B5, B5R, 8-1/2" x 13"
11" x 17", 8-1/2" x 11",
B4
sec_whale_keyope.fm  9 ページ  2002年11月13日 水曜日 午後6時0分
10
GENERAL PROGRAMS
Saddle stitch position adjust
This program is used to adjust the stapling position
(folding position) when using the saddle stitch
function of the optional saddle stitch finisher.
The value can be adjusted in 0.1 mm increments
within ±3.0 mm from the reference position for
each paper size.
[AUTOMATIC SADDLE STITCH] checkmark
The saddle stitch print function can normally be
divided into the following three general steps.
1. The pages of the original are automatically
reordered to allow saddle stitch binding (saddle
stitch function).
2. The pages are folded at the centre.
3. The paper is stapled at the centre in two places
(saddle stitch stapling).
The [AUTOMATIC SADDLE STITCH] checkbox is
selected by default.
Selection of the checkbox assumes the use of the
above saddle stitch printing function (three steps).
Saddle stitch stapling exceptions
Depending on the purpose of saddle stitch
stapling, it may be necessary to perform saddle
stitch stapling on printed matter that has already
been bound by saddle stitching. In this case, it is
necessary to disable step 1 above. If you
frequently perform this type of exceptional saddle
stitch stapling that requires disabling step 1,
remove the checkmark from the [AUTOMATIC
SADDLE STITCH] checkbox.
Stream feeding mode
This program is used to enable the stream feeding
mode of the document feeder. When the stream
feeding mode is enabled, additional originals which
are set in the document feeder tray within 5
seconds after the previous original was fed will be
fed and copied automatically.
Auto paper selection setting
Use this program to select the paper type* for
which the automatic paper selection function
operates. Selections are "Plain paper", "Plain
paper and recycle paper", and "Recycle paper".
* The paper type set for each paper tray in the
paper tray settings of the user settings (page 2-11
of the Operation Manual for general information
and copier operation).
Registration adjustment
Use this program when the colour of characters
and lines in colour printing is off. Registration
adjustment can be performed in two ways:
manually and automatically. Normally [AUTO
ADJUSTMENT] should be used.
● [AUTO ADJUSTMENT]
Touch this key to have registration adjustment
performed automatically.
After touching this key, touch the [EXECUTE]
key. A message appears when automatic
registration adjustment is completed. Touch the
[EXIT] key to exit.
● [MANUAL ADJUSTMENT]
Touch this key to perform registration
adjustment manually.
Use this key when you require a higher level of
precision than can be obtained with [AUTO
ADJUSTMENT]. See page 11 for the procedure
for manual registration adjustment.
1
2
12
11
Min. -3 mm
Max. +3 mm
Reference position
Position adjusted 
to the plus 
direction
Position adjusted 
to the minus 
direction
NOTE
The stream feeding mode will not function when the
covers mode has been selected.
sec_whale_keyope.fm  10 ページ  2002年11月13日 水曜日 午後6時0分
11
GENERAL PROGRAMS
● Manually adjusting the registration
The procedure for manually adjusting the registration is explained here. This procedure is used when you select manual
adjustment in the [Registration adjustment] key operator program explained on page 10.
Touch the [MANUAL ADJUSTMENT] key and then the [EXECUTE] key to print the adjustment pattern for manual
registration adjustment. This pattern consists of scales that show how much each of the colours C (cyan), M (magenta),
and Y (yellow) are off. If a colour deviates greatly from the reference value, it can be corrected by entering the deviation
value from the touch panel. Follow the steps below to manually adjust the registration.
Understanding the adjustment pattern
The amount of deviation is given within a range of -60 to 60, where 60 represents the maximum value and "0" represents
minimal deviation. (See the enlarged view of scale B.)
As shown in the diagrams, the scales indicating the range of deviation appear in pairs for each colour, with one scale
showing the x1 component of the deviation, and the other scale showing the x10 component.
Scale A consists of two scales for each colour (C1, M1, Y1 and C2, M2, Y2), and the peak value of the distribution range
of each colour on the scale is the x1 component of the deviation.
Adjustment is performed by entering the deviation, which is the total value of scale A and scale B. However, in most cases
adjustment is possible using just the deviation value from scale A. Follow these steps to perform adjustment.
1
In the manual registration adjustment screen
of the touch panel, touch the key of the colour
you wish to correct ([C1], [M1], [Y1], [C2], [M2],
or [Y2] key).
2
Use the 
 or 
 key to enter the scale A (x1)
value of the key selected in step 1.
● Repeat steps 1 and 2 to adjust the other colours.
● If the printed adjustment pattern is similar to the
example of C2 shown above (the peak in scale A
is between -1 and 1 and the value of scale B
overlaps "0"), correction is not necessary.
3
To print an adjustment pattern showing the
results of your entries, touch the [PRINT] key.
4
In the adjustment pattern printed in step 3,
verify that the peak of the distribution in
scale A is between -1 and 1 for each colour,
and that the scale B value overlaps "0". If
this is the case for all colours, respond to
the display messages by touching the
[YES] key and end adjustment. 
● If the scale B value of one (or more) of the
colours does not overlap "0", touch the [NO] key
to return to the screen of step 1.
● If a scale B value of a colour does not overlap "0",
the value overlaps 20, 40, 60, -20, -40, or -60 as
shown above. In step 2, enter the number that
the value overlaps as a multiple of 10.
5
Repeat steps 1 to 4 to complete
adjustment.
● You can touch the [OK] key at any time during
the adjustment procedure to store the
correction values entered to that point and end
manual registration.
● To cancel all corrections entered to that point
and return to the previous screen (before
manual registration was executed), touch the
[CANCEL] key.
60
40
20
0
-20
-40
-60
60
-60
60
-60
9 8 7 6 5 4 3 2 1 0 -1 -2 -3 -4 -5 -6 -7 -8 -9
9 8 7 6 5 4 3 2 1 0 -1 -2 -3 -4 -5 -6 -7 -8 -9
C1
C2
Example: Adjusting cyan (deviation in the primary scanning direction)
Adjustment pattern
Registration adjustment pattern of cyan in the secondary scanning direction
Scale A
Scale B
(Enlarged view of scale B)
Registration adjustment pattern of cyan in the primary scanning direction
Identify the peak of the distribution
C2
0
M2
M1
0
0
Y2
Y1
0
0
PRINT
C1
0
C2
0
M2
M1
0
0
Y2
Y1
0
0
PRINT
C1
5
sec_whale_keyope.fm  11 ページ  2002年11月13日 水曜日 午後6時0分
12
GENERAL PROGRAMS
■ List print
This program is used to print lists of key operator
programs.
Lists of key operator programs for copier, printer
and network scanner features are available.
■ Key operator code change
This program is used to change the key operator
code.
The key operator must register a key operator code
number and use the number to gain access to key
operator programs. Only one key operator code
number can be registered. The factory has
registered five zeros as the code number to allow
initial access to the programs. It is recommended
that the key operator use the factory number for
initial entry into the programs and then choose and
enter another number by this program.
■ Product key
Use these programs to input data required to
activate the following systems.
E-mail alert and status
This program cannot be used now. This program is
reserved for future customer support through a
network.
Network scanner expansion kit
This program must be used to activate the network
scanner expansion kit. For the password to be
entered, contact your dealer.
Serial number
Use this program to check the serial number of the