Sharp AR-C170 (serv.man29) Service Manual ▷ View online

AR-C170M  ROM VERSION UP  12 - 9
12) Confirm that downloading (copying to the Flash ROM) is com-
pleted on the computer display and on the LCD display. It nor-
mally takes 5 to 7 minutes to copy (write) to the Flash ROM.
When downloading is normally completed, the following indi-
cations are shown.
LED3 on the ICU PWB are turned off, and LED1 and LED2
flash at a low speed.
"FIRMWARE UPGRADE FINISHED" is displayed on the
LCD.
13) Cancel the simulation 49-1, and turn off the power of the
machine.
(Note)
If the Flash ROM is removed from or installed to the
machine with the machine power ON, the Flash ROM
may be destroyed. Be sure to turn off the power of the
machine before removing or installing the Flash ROM.
14) Remove the Flash ROM (which was upgraded) installed to the
ICU MAIN PWB Write socket in procedure 1).
When another Flash ROM is to be upgraded, install it to the ICU
PWB Write socket and turn on the power, and perform procedures
11) through 14).
B. Method using two Flash ROM sockets on the ICU MAIN PWB to copy between Flash ROM’s
1) Check that the power of the machine is OFF. Install the Flash
ROM (of either of ICU PWB, PCU PWB, or operation control
PWB) to the ICU PWB Write socket.
2) Install the source Flash ROM (which has the program data of
either of ICU PWB, PCU PWB, or operation control PWB) to
the ICU PWB Read socket.
3) Turn on the power of the machine. Copying is started. When
copying is completed, LED3 on the ICU PWB are turned off,
and LED1 and LED2 flash at a low speed. It normally takes 30
to 60 sec to copy (write) to the Flash ROM.
4) Turn off the power of the machine, and remove the Flash
ROM's from the Read and the Write sockets.
(After work)
1) Installed the copied Flash ROM to the specified PWB.
2) Turn on the power of the machine and check that the machine
operates normally.
3) Use the simulation 22-5 to check each ROM version.
4) Install the shield plate and the stopper shift. (3 screws)
5) Attach the right upper cabinet of the machine. (2 screws)
(NOTE)
The monitor displays before and after and during the Flash ROM version up (copy) operation are shown below. If the Flash ROM version up
operation is not completed normally or if the Flash ROM is not installed to the socket properly, a trouble code is displayed. In that case, per-
form the countermeasures shown in the table below.
(1)
ICU MAIN PWB monitor LED lighting specification
The monitor LED status during copy (write) operation of PC to Flash ROM and Flash ROM to Flash ROM is shown below. In the copy
mode of Flash ROM to Flash ROM, the machine status is indicated only with the monitor LED.
While in the copy mode of PC to Flash ROM, the status is indicated on the operation panel or the PC monitor.
Status LED lighting specifications
Status in bold means an error
LED1
LED2
Mode
Status 1
Low-
speed 
flashing
Low-
speed 
flashing
Normal operation
Status 2
High-
speed 
flashing
High-
speed 
flashing
System down
Display when writing the program data from PC to Flash ROM
Status 3
ON
OFF
Download SIM start
Status 4
OFF
Flashing
Download ROM not-installed 
error
Status 5
Flashing
ON
During data transfer from PC
Status 6
Flashing
Flashing
Data transfer error from PC
Status 7
ON
ON
Flash deleting
Status 8
OFF
Flashing
Flash deleting error
Status 9
Flashing
ON
Flash writing
Status 10
Flashing
Flashing
Flash writing error
Status 11
ON
ON
Verifying
Status 12
ON
Flashing
Verifying error
Status 13
Low-
speed 
flashing
Low-
speed 
flashing
Normal completion
LED1
LED2
Mode
Display when copying data from Flash ROM to Flash ROM
Status 14
ON
ON
ROM copy start
Status 15
OFF
Flashing
Download ROM not-installed 
error
Status 16
ON
ON
ROM capacity checking
Status 17
ON
Flashing
ROM capacity check error
Status 18
ON
ON
Flash deleting
Status 19
OFF
Flashing
Flash deleting error
Status 20
Flashing
ON
Flash writing
Status 21
Flashing
Flashing
Flash writing error
Status 22
ON
ON
Verifying
Status 23
ON
Flashing
Verifying error
Status 24
Low-
speed 
flashing
Low-
speed 
flashing
Normal completion
AR-C170M  ROM VERSION UP  12 - 10
(2)
Operation panel display specifications (SIM 49-1)
The operation panel display status in PC to Flash ROM copying (writing) is shown in the table below.
When the power of PC is down during data transfer, data transfer is performed from the beginning.
(In the case of Desk control PWB)
1) Remove the desk unit power source cover. (One screw)
2) Check that the machine power is off, and connect the PC and
the level converter desk unit serial I/F connector and the level
converter.
3) Turn on the PC, and start Windows.
4) Set the data transfer speed of PC.
In the case of Windows 95/98:
(4-1)
Open the "Control panel."
(4-2)
Open the "System."
Display message 
Operation/Content
Countermeasures
NOW EXECUTING ...
Simulation start
THIS COPIER IS NOT CONNECTED TO PC.
The cable is not connected.
Turn off the power of the copier machine, 
and check the connection again.
FLASH ROM ISN'T INSERTED INTO A CONNCTOR.
The writing Flash ROM is not 
inserted into the socket.
Turn off the copier machine, insert the 
Flash ROM.
WAITING FOR DATA
Waiting for starting the Flash ROM 
writing software on PC side
Boot the software for writing to Flash 
ROM on PC.
ERASING FLASH ...
Deleting
WRITING FLASH ...
Writing
VERIFYING FLASH ...
Verifying
FLASH ERASE ERROR.
Failure in erase of Flash ROM for 
writing
Try again, or replace the Flash ROM.
FLASH WRITE ERROR.
Failure in copy (write) of Flash ROM 
for writing
Try again, or replace the Flash ROM.
FLASH VERIFY ERROR.
Failure in verifying Flash ROM 
content for writing
Try again, or replace the Flash ROM.
DOWNLOADING NOW ...
Data downloading
DOWNLOAD ERROR.
Data transfer failure
Tray data transfer again, or tray simulation 
again.
FIRMWARE UPGRADE FINISHED.
Data transfer complete
THIS SIMULATION DOES NOT WORK IN THIS ROM 
VERSION.
Displayed when ICU Flash ROM 
does not support this simulation.
ICU Flash ROM Version up
AR-C170M  ROM VERSION UP  12 - 11
(4-3)
Click the "Device manager" and click the "Port (COM/
LPT)," and double-click the "Communication port
(COM*) to be used.
(4-4)
Set the bit/sec of port set menu to 38400.
If 38400 cannot be set, set either of the following com-
munication speeds.
9600/19200
In the case of Windows 2000:
(4-1)
Open the "Control panel."
(4-2)
Open the "System."
(4-3)
Open the "Device manager" on the hardware menu.
(4-4)
Click the "Port (COM/LPT)", and double-click the
"Communication port (COM*)" to be used.
 Double-click
 38400
 Double-click
AR-C170M  ROM VERSION UP  12 - 12
(4-5)
Set the bit/sec of the port set menu to 38400, and click
the OK button to close the communication port (COM*)
property.
If 38400 cannot be set, set either of the following com-
munication speeds.
9600/19200
5) Turn on the power of the machine. 
6) Enter the simulation 49-10 mode. (Press the EXECUTE key to
enter the download (Flash ROM writing) mode.)
7) Start the download program on the PC side by double-clicking
the Mainte.exe file. The following window is indicated.
8) Select the communication setup in the option menu, and set
the communication speed same as which is set in procedure
4).
9) Select the data file to be written.
(9-1)
Double-click the Simulation Command List folder. 
(9-2)
Double-click the Special (Whale Desk) folder.
(9-3)
Double-click the file Program Download, and the fol-
lowing dialog is displayed. Click the OK button.
(9-4)
Then the following dialog is displayed. Click the
START button.
(9-5)
The file selection dialog is displayed. Select the data
file to be written, and click the Open button.
 38400
Page of 13
Display