2 - 21 AR-651/810  ERROR CODES AND SELF-DIAGNOSIS
[0] [5]
[POWER]
[Digital key]
(Code)
[START]
[POWER]
OFF/ON
(Exit)
Automatic
adjustment
Procedure 6
[0] [5]
[POWER]
[Digital key]
(Code)
[START]
[POWER]
OFF/ON
(Exit)
Automatic
adjustment
Procedure 15
[CLEAR]
[SET]
or
 [INTERRUPT]
(Stores value in
RAM)
[0] [5]
[POWER]
[Digital key]
(Code)
[CANCEL]
[START]
[START]
[Digital key]
* [JOB STATUS] key
Enter a
value
[POWER]
OFF/ON
(Exit)
[ENERGY
SAVER]
Test
copy
(Stores value in
RAM)
[CLEAR]
(Corrects value)
[SET]
or
 [INTERRUPT]
* Press [JOB STATUS] to enter “–”.
[CLEAR]
(Corrects value)
[Digital key]
(Sub code)
Procedure 13
Note: The fuser roller temperature control at the adjustment mode is different from that at the normal
state. Therefore, the problem of fusing efficiency may be occured in the test copy at the adjustment
mode.
In that case, turn ON the power normally, leave the copier for approx. 3 minuites after it has become
ready state and then start up the adjustment mode again.
AR-651/810  ERROR CODES AND SELF-DIAGNOSIS 2 - 22
Adjustment mode (05)
Accept-
Code
Items to adjust
Function Default
able
Contents
value
200
201
205
206
210
211
221
242
268
269
290
291
Automatic adjustment of auto-toner
sensor (Fuser heater ON)
Correction of auto-toner sensor
(Fuser heater ON)
Developer bias DC output adjustment
Developer bias actual value
Main charger grid bias output adjust-
ment
Main charger grid bias actual value
Transfer transformer DC output ad-
justment/center value
Control status of the drum surface
potential sensor
Image quality control
Display of the exposure corrected value
Image quality control
Display of limiter flag
Enforced performing of Image quality
control
Image quality control
Control status display
ALL
 –
ALL
0~255
ALL
141
0~255
ALL
0~255
ALL
112
0~255
ALL
0~255
ALL
175
0~255
ALL
0
0~255
ALL
0
-255
~255
ALL
0
0~255
ALL
ALL
0
0~255
- As the value increases, the
sensor output increases
correspondingly.
- The value starts changing
approx. 2 minutes after this
adjustment was started and is
automatically set in the range of
2.45 to 2.55V.
 Chapter 3.2.)
As the value increases by “1”,
output from the transformer
increases correspondingly.
 Chapter 3.5.)
The developer bias value at the
latest printing is displayed.
As the value increases by “1”,
output from the transformer
increases correspondingly.
 Chapter 3.5.)
The main charger grid bias value
at the latest printing is displayed.
The voltage for the transfer belt
power supply roller can be
adjusted but cannot be meas-
ured.
* When carrying out an adjustment,
close the front cover and be
careful not to touch the high-
voltage section.
6
3
3
2
3
2
3
2
2
2
6
2
Operation
procedure
2 - 23 AR-651/810  ERROR CODES AND SELF-DIAGNOSIS
Adjustment mode (05)
Accept-
Code
Items to adjust
Function Default
able
Contents
value
292
293
296
305
306
308
340
354
355
356
357
358
Display of the output Sensor light
value of the image source  OFF
quality sensor
Drum surface
Display of the light amount adjustment
result of the image quality sensor
Adjustment of scanner secondary
scanning start position deviation
Adjustment of scanner primary scan-
ning start position deviation
Distortion mode
Adjustment of scanner secondary
scanning reproduction ratio
Adjustment of
for single-sided
RADF paper
original
alignment
for two-sided
original
Automatic adjustment of RADF sen-
sor and EEPROM initialization
Fine adjustment of RADF transport
speed
RADF sideways deviation adjustment
ALL
0~1023
ALL
0~1023
ALL
0~255
ALL
137
0~255
ALL
128
0~255
ALL
PPC
128
0~255
ALL
10
0~20
ALL
10
0~20
ALL
ALL
50
0~100
ALL
128
0~255
The output value of the image
quality sensor is displayed when
the sensor light source is OFF.
The output value of the image
quality sensor on the drum
surface (without a test pattern) is
displayed.
LED light amount adjustment of
the sensor, which makes the light
amount reflected from the drum a
standard velue is displayed.
When the value increases by “1”,
the image shifts toward the
leading edge of paper by approx.
0.1213mm.
When the value increases by “1”,
image shifts toward the rear side
of paper by approx. 0.0423mm.
Moves the carriages to the
adjustment position.
(
 Chapter 2.3.4.)
When the value increases by “1”,
the reproduction ratio of the
secondary scanning direction
decreases by approx. 0.025%.
When the value increases by “1”,
the aligning amount increases by
approx. 0.5mm.
Perform the adjustment and
initialization when the ADF board
or sensor of the RADF is re-
placed.
When the value increases by “1”,
the reproduction ratio of the
secondary scanning direction on
original fed from the RADF
increases by approx. 0.1%.
When the value increases by “1”,
the image of original fed from the
RADF shifts toward the rear side
of paper by approx. 0.0423mm.
2
2
2
1
1
6
1
1
1
6
1
1
Operation
procedure
AR-651/810  ERROR CODES AND SELF-DIAGNOSIS 2 - 24
Adjustment mode (05)
Accept-
Code
Items to adjust
Function Default
able
Contents
value
RADF leading
for single-sided
edge position
original
adjustment
f o r   t w o - s i d e d
original
RADF original tray Minimum
width sensor
Maximum
adjustment
Fine adjustment of polygonal motor
rotation speed (Reproduction ratio
adjustment of primary scanning direc-
tion)
Adjustment of primary scanning laser
writing start position
Adjustment of the
Normal speed
exit motor speed
Increased speed
Normal speed
Increased speed
Adjustment of the
Normal speed
reverse motor speed
Increased speed
Normal speed
Increased speed
Top margin adjustment (blank area
at the leading edge of the paper)
Left margin adjustment (blank area
at the left of the paper along the pa-
per feeding direction)
Right margin adjustment (blank area
at the right of the paper along the pa-
per feeding direction)
Bottom margin adjustment (blank
area at trailing edge of paper)
When the value increases by “1”,
the copied image of original fed
from the RADF shifts toward the
trailing edge of paper by approx.
0.1mm.
When the value increases by “1”,
the reproduction ratio of the
primary scanning direction
increases by approx. 0.07%.
(approx.0.5mm/5steps)
When the value increases by “1”,
the writing start position shifts to
the front side by approx.
0.0423mm.
When the value increases by “1”,
the rotation speed increases by
approx. 0.24%.
When the value increases by “1”,
the rotation speed increases by
approx. 0.32%, 0.37% (AR-651)
or 0.43% (AR-810).
Same as 424-0.
Same as 424-1.
When the value increases by “1”,
the rotation speed increases by
approx. 0.195%.
When the value increases by “1”,
the rotation speed increases by
approx. 0.28%, 0.32% (AR-651)
or 0.37% (AR-810).
Same as 426-0.
Same as 426-1.
When the value increases by “1”,
the blank area becomes wider by
approx. 0.0423mm.
365
366
367
368
401
405
410
411
424-0
424-1
425-0
425-1
426-0
426-1
427-0
427-1
430
431
432
433
1
1
6
6
1
1
1
1
13
13
13
13
13
13
13
13
1
1
1
1
ALL
50
0~100
ALL
50
0~100
ALL
ALL
PRT
133
0~255
PPC
129
0~255
PPC
128
0~255
PRT
128
0~255
PPC
128
0~255
PPC
128
0~255
PRT
128
0~255
PRT
128
0~255
PPC
128
0~255
PPC
128
0~255
PRT
128
0~255
PRT
128
0~255
PPC
0
0~255
PPC
0
0~255
PPC
0
0~255
PPC
0
0~255
Operation
procedure
Page of 127
Display