Sharp AR-651 (serv.man8) Service Manual ▷ View online

AR-651/810  GENERAL OPERATIONS  4 - 5
4. 2. 4.  Bypass copying
(1) Paper inserted into bypass feed tray.
SFB feed sensor turned ON
~ “READY FOR BYPASS FEEDING” displayed
(2) [START] key pressed
“READY FOR BYPASS FEEDING” display changed to “COPYING”
Main charger, developer bias and discharge lamp turned ON/Each fan rotating at a high speed
Drum, developer unit, transfer belt, and fuser roller rotating
(3) Sheet-bypass feeding
Bypass pickup solenoid turned ON and feed motor rotating in reverse
~ Bypass pickup roller lowered
Bypass feed clutch turned ON
~ Bypass feed roller, paper feed roller, and separation roller rotating
Aligning operation
Paper reaching registration roller
Bypass pickup solenoid, feed motor and bypass feed clutch turned OFF in a certain period of
time later
(4) Same operations as (3) through (6) of cassette feed copying with [START] key ON carried out
4. 2. 5.  Interrupt copying
(1) [INTERRUPT] key pressed
Interruption lamp turned ON
Copying operation temporarily halted and carriages-1 and -2 returning to their home position
“JOB INTERRUPTED JOB 1 SAVED” displayed
Copying mode set to automatic density and 1-to-1 reproduction ratio and copy quantity indicator
unchanged
(2) Preferred copying modes specified
(3) After an interrupt copying is terminated:
“PRESS INTERRUPT TO RESUME JOB 1” displayed
Interruption lamp turned OFF/Copier returning to  conditions before interruption when [INTERRUPT]
key is pressed again
“READY TO RESUME JOB 1” displayed
(4) [START] key pressed
Back to copying operation before interruption
AR-651/810  GENERAL OPERATIONS  4 - 6
4. 3.  Abnormality Detection
When an abnormality occurs in the copier, a symbol corresponding to the type of the abnormality is
displayed to draw the operator’s attention.
4. 3. 1.  Abnormality classification
A) Abnormalities which can be cleared without resetting the door switch
(1) Add paper
(2) Paper misfeed in bypass
(3) Set key copy counter
B) Abnormalities which cannot be cleared without resetting the door switch.
(1) Misfeed in copier
(2) Developer unit not installed properly
(3) Add toner
C) Abnormalities which cannot be cleared without turning OFF the main switch
(1) Call for service
4. 3. 2.  Abnormality description
A-1) Add paper
Empty sensor detects the presence or absence of paper.
[When cassette is not installed]
No Cassette detected
Tray not going up (empty sensor  OFF)
“Add paper” displayed
[START] key disabled
[When cassette is installed]
Cassette detected
Tray going up (empty sensor  OFF)
“Add paper” displayed
[START] key disabled
AR-651/810  GENERAL OPERATIONS  4 - 7
When power is turned ON or feed unit initializing is operated:
Presence or absence of paper detected
Tray motor  ON ~ Tray going up
When tray-up sensor is not turned ON within a certain period of time:
Tray being abnormal
“Add paper” displayed regardless of paper being present
or not
Turn ON and OFF the power to clear this condition.
When tray-up sensor is turned ON within a certain period of time:
~ Tray motor stopping
         At this time, if empty sensor is ON  ~ Determined there is a paper
if empty sensor is OFF  ~ Determined there is no paper
       
“Add paper” display blinked
When the remaining sheets of paper are getting short during copying:
Tray-up sensor turned OFF 
→ 
Tray-up motor turned ON ~ Tray going up
Tray-up sensor turned ON 
→ 
Tray motor stopping
When empty sensor is turned OFF despite tray-up sensor being ON during copying:
Determined there is no paper
“Add paper” display blinked
Copying stopped
AR-651/810  GENERAL OPERATIONS  4 - 8
A-2)
Bypass misfeed ( 
 )
When doing a bypass feeding:
Bypass feed pickup solenoid turned ON
Registration sensor turned ON
* When the registration sensor is not turned ON after a certain period of time (E12):
Bypass misfeeding
“Clear paper” symbol ( 
 ) displayed
Copying operation disabled
Solution: Remove paper from the bypass tray, and the bypass sensor will be turned OFF.
A-3)
Set key copy counter
When the key copy counter (optional) is pulled out from the copier which installs it:
“Set key copy counter” displayed
Copying operation disabled
When the counter is pulled out during copying:
Copying is stopped when the key copy counter is pulled out.
Page of 14