C. Details of simulations
1
1 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the scanner unit and its control circuit.
Section
Optical (Image scanning)
Item
Operation
Operation/
Procedure
1. Select the copy (scanning) magnification ratio with the zoom key.
The magnification ratio can be increased or decreased with the [ZOOM] key by the increment of 1%.
The selected magnification ratio is displayed on the magnification ratio display.
2. Press the [EXECUTE] key.
Scanning is performed at the magnification ratio set in procedure 1 is executed. During scanning, the [EXECUTE] key
is highlighted.
If the [EXECUTE] key is pressed under this state, the operation is interrupted. After completion of scanning, the
[EXECUTE] key returns to the normal display.
To resume scanning, start with procedure 2.
To change the magnification ratio, start with procedure 1.
Scanning is performed at the max. scanning length (432mm). If, however, the magnification ratio is set to greater than
100%, the scanning length is changed accordingly.
Note
1 - 2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operatioin of sensors and detectors in the scanner section and the related circuit.
Section
Optical (Image scanning)
Item
Operation
Operation/
Procedure
The operations of sensors and detectors in the scanner section are displayed.
The active sensors and detectors are highlighted.
Note
8 – 29
2
2 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to adjust the time from detection of the copy paper lead edge by PPD3 to OFF of the transport roller clutch
(TRC2/TRC1).
The copy paper stops before reaching the resist roller.  This simulation is used to adjust the stop position.
Section
ADF/RADF/UDH/SPF
Item
Operation
Operation/
Procedure
1. Select the aging mode with the key.
When selection is made, the selected item is highlighted.
[1:SIDE]: Single copy aging mode
[2:SIDE] Duplex copy aging mode
(Note) [2:SIDE] is displayed only when the unit which allows duplex copy is installed.
2. Select the copy magnification ratio with the key.
(The magnification ratio can be increased or decreased in the increment of 1% with the [ZOOM] key.)
The selected magnification ratio is displayed on the magnification ratio display on the screen.
The magnification ratio can be set only when SPF is installed.
3. Press the [EXECUTE] key.
Aging of the document feeder is executed under the conditions specified with procedures 1 and 2.
During aging, the [EXECUTE] key is highlighted. If the [EXECUTE] key is pressed while it is highlighted, the operation
is interrupted.
When two or more operations are selected in procedure 1, "1:SIDE" (single copy aging mode) is unconditionally
performed and the other highlighted displays return to the normal display.
To resume aging, execute with procedure 3.
To change the conditions for aging, execute with procedure 1.
When the SPF is installed , the magnification ratio can be adjusted in the range of 64% - 200%.
Note
8 – 30
2 - 2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of sensors and detectors in the RADF/ADF/SPF units and the related circuit.
Section
SPF/ADF/RADF/UDH
Item
Operation
Operation/
Procedure
The operations of sensors and detectors in the RADF/ADF/SPFsection are displayed.
The active sensors and detectors are highlighted.
[ADF/RADF installed]
DSS
Empty sensor
Normal display: Document empty
Highlighted: display: Document exist
DFD
Resist sensor
Normal display: Document empty
Highlighted display: Document exist
DTD
Paper timing sensor
Normal display: Document empty
Highlighted display: Document exist
AUOD
DF open/close sensor
Normal display: Close
Highlighted display: Open
TSS1
Tray feed size sensor (large size)
Normal display: Document empty
Highlighted display: Document exist
TSS2
Tray feed size sensor (small size)
Normal display: Document empty
Highlighted display: Document exist
DWS1
Tray width sensor (182mm)
Normal display: OFF
Highlighted display: ON
DWS2
Tray width senso
 (210mm/215.9mm)
Normal display: OFF
Highlighted display: ON
DWS3
Tray width sensor (257mm)
Normal display: OFF
Highlighted display: ON
DWS4
Tray width sensor (279.4mm)
Normal display: OFF
Highlighted display: ON
DWS5
Tray width sensor (297mm)
Normal display: OFF
Highlighted display: ON
RDD
Paper exit sensor
Normal display: OFF
Highlighted display: ON
[SPF installed]
DSS empty sensor
Normal display: Document empty
Highlighted display: Document exist
DFD resist sensor
Normal display: Document empty
Highlighted display: Document exist
RDD paper exit sensor
Normal display: Document empty
Highlighted display: Document exist
AUOD DF open/close sensor
Normal display: Close
Highlighted display: Open
TSS1 tray feed size sensor (large size)
Normal display: Document empty
Highlighted display: Document exist
TSS2 tray feed size sensor (small size)
Normal display: Document empty
Highlighted display: Document exist
DWS1 tray width sensor (182mm)
Normal display: OFF
Highlighted display: ON
DWS2 tray width sensor
(210mm/215.9mm)
Normal display: OFF
Highlighted display: ON
DWS3 tray width sensor (257mm)
Normal display: OFF
Highlighted display: ON
DWS4 tray width sensor (279.4mm)
Normal display: OFF
Highlighted display: ON
DWS5 tray width sensor (297mm)
Normal display: OFF
Highlighted display: ON
Note
8 – 31
2 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the loads in the RADF/ADF/SPF units and the control circuits.
Section
ADF/RADF/UDH/SPF
Item
Operation
Operation/
Procedure
1. The names of the loads which can be operated are displayed. Select the load to be checked with the key, and the
selected load is highlighted.
2. Press the [EXECUTE] key.
The load selected in procedure 1 starts the operation. During the operation of the load, the [EXECUTE] key is
highlighted. If the EXECUTE key is pressed while it is highlighted, the operation is stopped.
When two or more operations are selected in procedure 1, the operation is performed in the sequence of display
order.
[When ADF/RADF is installed]
DFM
FORWORD Paper feed motor forward rotation
DFM
REVERSE Paper feed motor reverse rotation
DTM
FORWORD Transport motor forward rotation
DTM
REVERSE Transport motor reverse rotation
DRM
Paper expulsion motor
DFSOL
Paper feed solenoid
[When SPF is installed]
DTM
FORWORD  Transport motor forward rotation
DTM
REVERSE Transport 
motor 
reverse 
rotation
STAMP
SOL
Stamp solenoid
Note
8 – 32
Page of 118
Display