DOWNLOAD Sharp AR-235 (serv.man2) Service Manual ↓ Size: 2.63 MB | Pages: 25 in PDF or view online for FREE

Model
AR-235 (serv.man2)
Pages
25
Size
2.63 MB
Type
PDF
Document
Handy Guide
Brand
Device
Copying Equipment / AR235 and AR275 Technical Launch Pack
File
ar-235-sm2.pdf
Date

Sharp AR-235 (serv.man2) Handy Guide ▷ View online

                                                                                        
AR-235/275
 Technical Information Pack
Document Systems Support
21
12.
Labour Cost & Service Times
Maintenance
cycle
Action
Replacement
Time
50000
Replace Drum (AR-270DR)
5 min
50000
Replace Developer (AR-270DV)
5 min
100000
100k PM kit (AR-270KA1)
10 min
150000
Upper heat roller kit (AR-270UH)
15 min
300000
Lower heat roller kit (AR-270LH)
15 min
Service Interval
Service
Time
Labour cost
@£25.00
per hour
Pence per
copy
Labour cost
@£30.00
per hour
Pence per
copy
50k
10mins
£4.17
0.0083ppc
£5.00
0.0100ppc
100k
20mins
£8.33
0.0083ppc
£10.00
0.0100ppc
150k
35mins
£14.58
0.0097ppc
£17.50
0.0116ppc
300k
50mins
£20.83
0.0069ppc
£25.00
0.0083ppc
*m/c call every 25k
45mins
£18.75
0.0375ppc
£22.50
0.0450ppc
*Calculated on the target MCBF of 25K and an average call duration of 45 minutes.
AR235/ AR275 Consumable Costs
The table below presents the CPC of Leopard.
The main consumables are Toner, Developer and Drum; these will be of most interest to the
Reseller. The costs of these components are very favourable in comparison to both Panther
and  Cougar.  The  key  element  will  be  the  toner;  Panther  toner  is  currently  at  0.227ppc  vs
0.160 ppc on Leopard, although the toner life has increased the majority of the cost comes
from the toner cartridge housing, that is why the cost is not half that of Panther.
With the introduction of Leopard, we have also introduced a main charger kit, which will also
fit the Panther, reducing the cost from £59 as a part to £8.90 as a kit.
Item
Description
LIFE
Trade
Reseller
CPC
AR270DM
OPC Drum
50000
£22.62
£19.00
0.038
AR270LD
Developer( Box of 10)
500000 £141.67
£119.00
0.024
AR270LT
Toner ( Box of Ten)
250000 £475.00
£399.00
0.160
0.221
AR270UH
Upper Heat Roller Kit
150000 £44.05
£37.00
0.025
AR270LH
Lower Heat Roller Kit
300000 £54.76
£46.00
0.015
AR270KA
Maintenance Kit
100000 £38.10
£32.00
0.032
AR270MC
Main Charger Kit (10)
500000 £105.95
£89.00
0.018
AR270CB
Cleaner Blade Box of 10 500000 £78.57
£66.00
0.013
0.141
                  Grand Total
0.362
                                                                                        
AR-235/275
 Technical Information Pack
Document Systems Support
22
13.     Safety Data Sheet
1.    Model               :              
AR-235 / AR-275
                  
    
                                 
 
 
1.1  (electr.) Safety      :               Inspected acc;
 TUV(GS-MARK)
SEMKO,NEMKO      
 
 
Fire protection       :              acc. To NFPA  ;
               -
 
 
1.3  Radio Interference Suppression :  inspected acc.  ;
 CE-Mark
 
 
1.4  Other tests          :                       (e.g....) ;
               -
 
 
1.5  Power consumption :  operation   ;        1000     W    (MAX. with option)
 
 
                              standby mode ;                   92.3       Wh/h
 
 
                              off mode;                           10.6      Wh/h
 
 
2.    Emission
       Measurement procedure :
  According to Blue Angel (25
, 50%RH)
 
 
       Measurement conditions :  room volume            ;       50      m
3
 
 
                                 air exchange     ;      None    per hour
 
 
                                 test copy volume ;      2,225    no. of copies
 
 
                                 testing time              ;        2      hours
 
 
 2.1  Heat (released) :  operation          ;      3600      kJ =      3412      
 
 
BTU
 
 
                        standby mode          ;      332.28      kJ =      314.93     
 
 
BTU
 
 
                        off mode ;       38.16     kJ =       36.17      
 
 
BTU
 
 
                                       (36x10
J = 1 kwh = 3412 BTU )
 2.2  Ozone concentration :      0.0136     mg/m
3
 < 0.196mg/m
3
 ( =0.1ppm )
 
 
 2.3  Dust concentration   :      0.006      mg/m
3
 < 6.0mg/m
3
 
 
       Styrene-emission    :      0.010     mg/m
3
 < 0.11mg/m
3
 (RAL-UZ62 Supplement3)
 
 
 2.4  UV-radiation         :     None
   
 
 
 2.5  Noise emission (max.
  2.5.1  Sound power level  :   standby   ;      31.7     dB(A)
 
 
                                operation ;      62.7(FAST) / 65.6(IMPULSE)    dB(A)
 
 
  2.5.2  Workplace related
         Sound pressure level:   standby      ;  
     38.5     dB(A)
 
 
                                 Operation ;       50.3      dB(A)
 
 
                                  Puls            ;     No data    dB(A)
 
 
 2.6
NO :      No data     ppm <  5.0 ppm
 
 
2.7
CO :      No data     ppm < 30.0 ppm
 
 
3.     Max. air flow :        No data        m
3
/min.
 
 
4.     Set up conditions
 4.1   Minimum set up space:
   L;     585.5       W;   
 
 
  623       H;   
 
 
 650.5      mm
 
 
 4.2   Air circulation:              Not specified               e.g. 0.5/h
 
 
 4.3   Average monthly copy volume:        10,000~13,000        e.g. 1,000
 
 
 4.4   Room climate:   humidity           ;     20    % min.    
 
 
  85    % max.
 
 
                         temperature ;     10    
 min.      3
 
 
5    
 max.
 
 
                                                                                        
AR-235/275
 Technical Information Pack
Document Systems Support
23
Material  Safety  Data  Sheet  (1/2)
                                                                                                                      MSDS No. F-00981
Section 1.  Product  Identification
 Product 
:
 AR-270NT / T / FT / ST / ST-C / ST-T / NT-J, AR-ST28-B, DM-270TD / TD-B (Black Toner)
Section 2.  Supplier’s  Name  and  Address
 Sharp Corporation
 22-22 Nagaike-cho, Abeno-ku, Osaka, Japan
 Local suppliers are listed below.  Please contact the nearest supplier for additional information.
(Country)
(Name  and  Telephone  Number)
U.S.A.
Sharp Electronics Corporation
Telephone number for information: 1-800-237-4277
Emergency telephone number  : 1-800-255-3924
Canada
Sharp Electronics of Canada Ltd.
Telephone number for information: 905-890-2100
Emergency telephone number  : 1-800-255-3924
United
Kingdom
Sharp Electronics (U.K.) Ltd.
Telephone number for information: 01923-474013
Section 3.  Ingredients
       Ingredients
CAS No.
 
 
       Proportion
 
 
   
OSHA
 
 
      PEL   ACGIH
 
 
     TLV   Other
 
 
 
 
 Styrene-Acrylate copolymer    29497-14-1
         88 %
     Not listed
      Not listed
None
 Carbon black                           1333-86-4
           6.0%       3.5mg/m
3        
3.5mg/m
3
None
 Iron oxide                                 1309-38-2
          4.5%
      Not listed
      Not listed
None
 Metal Complex dye                  109125-51-1
      1.5%
       0.5mg/m
3
     0.5mg/m
3
None
  
Section 4.  Hazardous  Identification  (Emergency  Overview)
Toner is a fine, black powder possessing no immediate hazard.  There are no anticipated carcinogenic effects
from exposure based on animal tests performed using toner.  When used as intended according to instructions,
studies do not indicate any symptoms of fibrosis will occur.
Section 5.  Health  Hazard  Data
Route(s) of Entry  :  Inhalation?
Skin?
 
 
Ingestion?
 
 
 
 
 
    Yes
 No
Possible but very unusual.
Health Hazards : Acute oral toxicity LDL of this toner is over 2,000mg/kg.
Mutagenicity The result of Ames test is negative.
Carcinogenicity  :  In  1996  the  IARC  reevaluated  carbon  black  as  a  Group  2B  carcinogen  (possible  human
carcinogen).  This classification is given to chemicals for which there is inadequate human evidence, but sufficient
animal evidence on which to base an opinion of carcinogenicity. The classification is based upon the development
of  lung  tumors  in  rats  receiving  chronic  inhalation  exposures  to  free  carbon  black  at  levels  that  induce  particle
overload of the lung.  Studies performed in animal models other than rats did not show any association between
carbon black and lung tumors.  Moreover, a two-year cancer bioassay using a typical toner preparation containing
carbon black demonstrated no association between toner exposure and tumor development in rats.
Chronic Effect: In a study in rats of chronic inhalation exposure to a typical toner, a mild to moderate degree of
lung fibrosis was observed in 92% of the rats in the high concentration (16mg/m
3
) exposure group, and a minimal
to  mild  degree  of  fibrosis  was  noted  in  22%  of  the  animals  in  the  middle  (4mg/m
3
)  exposure  group,  but  no
pulmonary  change  was  reported  in  the  lowest  (1mg/m
3
)  exposure  group,  the  most  relevant  level  to  potential
human exposures.
Signs and Symptoms of Exposure: Minimal irritation to respiratory tract may occur as with exposure to any non-
toxic dust.
Medical Conditions Generally Aggravated by Exposure :  None
                                                                                        
AR-235/275
 Technical Information Pack
Document Systems Support
24
Material Safety Data Sheet  (2/2)
                                                                                                                     MSDS No. F-00981
Section 5.  Health  Hazard  Data (Continued)
Emergency and First Aid Procedures   :
Inhalation; Remove to fresh air.  If effects occur, consult medical personnel.
Eye: In case of contact, immediately flush eyes with water for 15 minutes.
Section 6.  Physical  Chemical  Characteristics
Boiling Melting Point
:
Not applicable     Specific Gravity :1.1
Vapor Pressure :
Not applicable     Solubility in Water:
Negligible
Vapor Density
:
Not applicable     PH:Not applicable
Evaporation Rate
:
Not applicable     Viscosity:Not applicable
Appearance
:
Fine powder        Color:Black
Odor
:
Odorless
Section 7.  Fire  and  Explosion  Data
Flash Point (Method Used)
:Not applicable
Ignition Temperature
:350
0
C
Flammable Limits
:(LEL); Not applicable  (UEL); Not applicable
Extinguishing Media
:CO2, dry chemical, foam or water
Special Fire Fighting Procedure
:None
Unusual Fire and Explosion Hazard
:This material has no unusual fire or explosion hazards.
Sensitivity to Mechanical Impact :None
Sensitivity to Static Charge
:None
Section 8.  Reactivity  Data
Stability :Stable
Incompatibility (Material to Avoid)
:None
Hazardous Decomposition
:CO and NOx
Hazardous Polymerization
:Will not occur.
Section 9.  Precautions  for  Safe  Handling  and  Use
Personal Protection Information (Respiratory, Eye Protection and Protective Glove): Use of a dust mask is
recommended when handling a large quantity of toner or during long term exposure, as with any non-toxic dust.
Engineering Control / Ventilation :Not required.
Work / Hygienic Practice                              :Inhalation should be minimized as with any non-toxic dust.
Steps to be taken in case of Spill or Leak   :Sweep up or clean up with vacuum cleaner.
Waste Disposal Method  :Waste material may be dumped or incinerated under conditions which meet all
federal, state and local environmental regulations.
Section 10.  Regulatory  Information
NFPA Rating (U.S.A.)
                    :Health = 1
Flammability = 1
Reactivity = 0
WHMIS Legislation (Canada)       :This product is not a controlled product.
Transport Information                   :This product is not a hazardous material.
UN No. :None allocated.
Section 11.  Other  Information
References  : IARC (1996) IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to
Humans, Vol. 65, Printing Process and Printing inks, Carbon Black and Some Nitro Compounds, Lyon, pp-149-
261 H. Muhle, B. Bellmann, O. Creutzenberg, C. Dasenbrock, H. Ernst, R. Kilpper, J. C. MacKenzie,
 P. Morrow,
U. Mohr, S. Takenaka, and R. Mermelstein (1991) Pulmonary Response to Toner upon Chronic
Inhalation Exposure in Rats.  Fundamental and Applied Toxicology 17, pp. 280-299
Page of 25
Display