DOWNLOAD Sharp AR-205 (serv.man10) Service Manual ↓ Size: 90.01 KB | Pages: 14 in PDF or view online for FREE

Model
AR-205 (serv.man10)
Pages
14
Size
90.01 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR205 Service Manual-Simulations
File
ar-205-sm10.pdf
Date

Sharp AR-205 (serv.man10) Service Manual ▷ View online

Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
26
1
Option switch display
Used to display the installed option on the operation panel. (The LED
corresponding to the installed option is lighted.)
3
Auditor setting
Used to display the current auditor setting with the numbers at right. 
After entering the set value, press the start key, and the set value is
stored.
0
  2
5
Counter mode setting
Used to set the print counter mode in A3 or 11" 
×
 17".
Used to display the currently set counter value with the numbers at right.
After entering the set value, press the start key, and the set value is
stored.
0
  3
6
Destination setting
Used to display the current destination setting with the numbers at right.
After entering the set value, press the start key, and the set value is
stored.
0
 11
Key operation
Display
Display select: 
  Magnification
ratio display key
<Lighting with an option installed>
When “A” is displayed:
Shifter: Paper empty LED
Job separator: JAM LED
SPF: SPF select LED
RSPF: SPF JAM LED
Duplex mode: Main cassette select LED
Simplex mode: Multi manual paper feed select LED
When “b” is displayed:
Cassette (2nd step): No. 2 cassette select LED
Cassette (3rd step): No. 3 cassette select LED
Cassette (4th step): No. 4 cassette select LED
Memory installed: Paper empty LED
FAX: JAM LED
Printer: Main body JAM LED
ERDH: Main cassette select LED
16CPM: SPF JAM LED
20CPM: SPF select LED
Document sensor: Auto paper select LED
Key operation/Display
0: Built-in auditor
1: Coin vendor
2: Others
Key operation/Display
0: Total/Developer = 2 counts
Maintenance = 2 counts
1: Total/Developer = 1 count
Maintenance = 2 counts
2: Total/Developer = 2 counts
Maintenance = 1 count
3: Total/Developer = 1 count
Maintenance = 1 count
Key operation/Display
  0: Japan
  6: France (AB series)
  1: USA (Inch series)
  7: EX inch series
  2: Canada (Inch series)
  8: EX AB series
  3: Germany (AB series)
  9: EX inch series (FC conformity)
  4: UK (AB series)
10: EX AB series (FC conformity)
  5: Australia (AB series)
11: Taiwan, China (AB series)
AR-205
7 – 7
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
26
10
Model name setting
Used to set the model name of the machine used with the following
numbers. After entering the set value, press the start key and the set
value is stored.
0
 19
22
Language setting
Used to display the current setting of the language information with the
number at right. After entering the set value, press the start key, and the
set value is stored.
0
  7
30
CE mark conformity
control setting
Used to display the current setting of CE mark conformity control with
the number at right. After entering the set value, press the start key, and
the set value is stored.
0
  1
32
Fan rotation duty change
state setup
The currently set fan motor rotation duty is displayed with the following
numbers. After entering the set value, press the start key to store the
set value.
0
0.1
38
Cancel of stop at drum
life over
<Not Used>
The currently set value is displayed. After entering the set value, press
the start key to store the set value.
0
  1
42
Transfer timing adjustment
After completion of warm up, shading is performed and the currently set
transfer timing adjustment value is displayed.
5
1, 3, 5, 7, 9
50
Black-white reversion
function setup
The current setup of black-white reversion is displayed with the following
numbers. After entering the set value, press the start key to store the
set value.
0
0.1
Key operation/Display
 0: AL-1600
11: AR-N200
 1: AL-1610
12: AR-N205
 2: AL-1620
13: AL-1621
 3: AL-1640/AL-1641
14: AL-1650
 4: AR-160/AR-S160
15: AL-1670
 5: AR-161/AR-S161
16: AR-F200
 6: AR-200S
17: DM-2000
 7: AR-200/AR-S200
18: DM-2005
 8: AR-205/AR-S205
19: DM-2010
 9: AR-F160
10: AR-F205
Key operation/Display
0: Japanese
4: Italian
1: English
5: Dutch
2: French
6: Swedish
3: German
7: Spanish
Key operation/Display
0: CE mark control OFF
1: CE mark control ON
Key operation/Display
0: Operating 50%, standby 30%
1: Operating 80%, standby 50%
Key operation/Display
0: The machine stops at drum life over.
1: The machine does not stop at drum life over.
Key operation
Transfer timing adjustment value: Copy quantity keys
“1”: 240 ms
“3”: 260 ms
“5”: 280 ms
“7”: 300 ms
“9”: 320 ms
Key operation/Display
0: Black-white reversion function enabled
1: Black-white reversion function disabled
AR-205
7 – 8
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
26
51
Sort/Group copy
temporary stop function
setup
<Only when an option
is installed>
Used to set whether temporary stop for every 250-sheet print (150-sheet
print when the job separator is installed) is made or not during copying
with the sort/group function. The current setup is displayed with the
following numbers. After entering the set value, press the start key to
store the set value.
1
0.1
30
1
Machine sensor operation
check
Used to check the sensors in the machine transport system with LED on
the operation panel.
41
2
OC document sensor
adjustment
<Other than AR-160>
Used to read the document sensor input value with paper and perform
the sensor detection level adjustment. For the adjustment procedure of
the document sensor input value, refer to the previous descriptions.
41
3
Document sensor light
reception level display
<Other than AR-160>
Used to display the light reception level and the detection level of the
document sensor. (The sensor level adjusted with SIM 41-2 is displayed.)
42
1
Developing counter clear
Used to clear the Developing counter. 
2
43
1
Fusing temperature setting
Used to display the current setting of the fusing temperature at right.
After selecting the fusing temperature with the magnification ratio display
key, press the start key, and the set value is stored. The set range is
155 
 190˚C. Use the magnification ratio key to adjust the value by –5˚C.
180
155 
 190
46
1
Copy density level
adjustment
After completion of warmup, shading is performed and the currently set
copy density level is displayed. For the adjustment procedure, refer to
the previous descriptions.
48
 99
2: Display after clearing each counter 
000 (0.75 sec) 
 Blank (0.35 sec) 
 000 (0.75 sec) 
 Blank (1.0 sec) 
 Repetition
Key operation/Display
0: Does not stop.
1: Stops.
Display
<Lighting at sensor ON>
Paper entry sensor: Machine position JAM LED
Duplex sensor: SPF JAM LED <Only AR-205>
Paper exit sensor: JAM LED
No. 2 cassette transport sensor: No. 2 cassette position LED
No. 3 cassette transport sensor: No. 3 cassette position LED
<Only when an option is installed>
No. 4 cassette transport sensor: No. 4 cassette position LED
<Only when an option is installed>
Drum initial SW: DRUM LED
Key operation
Display
Light reception/Detection
level select: Magnification
ratio display key
Display at the 3rd digit
“A”:
Light reception level display
“b”:
Document detection level display
Sensor select: Auto
magnification ratio select key
Sensor A: A3 (11 
×
 17) document
size LED
Sensor B: A4 (8 1/2 
×
 14) document
size LED
Sensor C: A4R (8 1/2 
×
 11)
document size LED
Sensor D: B4 (8 1/2 
×
 5 1/2)
document size LED
Key operation
Fusing temperature select: Magnification ratio display key
Key operation
Display
Mode select:
Exposure mode select
key
Copy density level:
Copy quantity keys
<LED lighting at each mode selection>
Auto mode: AUTO LED
Manual mode: MANUAL LED
Photo mode: PHOTO LED
Toner save mode: MANUAL + PHOTO LED
AETS mode: AUTO + PHOTO LED
AR-205
7 – 9
Main 
code
Sub 
code
Contents
Details of operation
Initial 
value
Set range
48
1
Main scanning (front/rear)
direction magnification
ratio adjustment
(Copy/FAX/OC-SPF
common)
After completion of warmup, shading is performed and the currently set
main scanning (front/rear) direction magnification ratio adjustment and
the OC mode document center off adjustment are performed. For the
adjustment procedure, refer to the previous descriptions.
58
 99
2
OC mode sub scanning
direction magnification
ratio adjustment in
copying
After completion of warmup, shading is performed and the currently set
OC mode sub scanning direction magnification ratio adjustment in
copying is performed. For the adjustment procedure, refer to the
previous descriptions.
50
 99
5
SPF mode sub scanning
direction magnification
ratio adjustment in
copying
<Only when an option
is installed>
After completion of warmup, shading is performed and the currently set
SPF mode sub scanning direction magnification ratio adjustment in
copying is performed. For the adjustment procedure, refer to the
previous descriptions.
33
45
 99
6
OC mode sub scanning
direction magnification
ratio adjustment in FAX
<Only when an option
is installed>
After completion of warmup, shading is performed and the currently set
OC mode sub scanning direction magnification ratio adjustment in FAX is
performed. For the adjustment procedure, refer to the previous
descriptions.
50
 99
7
SPF mode sub scanning
direction magnification
ratio adjustment in FAX
<Only when an option
is installed>
After completion of warmup, shading is performed and the currently set
SPF mode sub scanning direction magnification ratio in FAX is
performed. For the adjustment procedure, refer to the previous
descriptions.
50
 99
Key operation
Display
Adjustment mode
select: Magnification
ratio display key
Auto magnification ratio adjustment:
 AUTO 
LED
Manual main scanning
direction magnification
ratio adjustment
Set value: Copy
quantity keys
Manual magnification ratio adjustment:
 MANUAL 
LED
OC mode document center off adjustment:
 PHOTO 
LED
Key operation
OC mode sub scanning direction magnification ratio in copying:
                                              Copy  quantity  keys
Key operation
Display
Adjustment mode select:
  Exposure mode select key
Auto: SPF mode sub scanning
direction magnification ratio in copying
Set value:
  Copy quantity keys
Manual: RSPF mode sub scanning
direction magnification ratio in copying
Key operation
OC mode sub scanning direction magnification ratio in FAX:
                                              Copy  quantity  keys
Key operation
SPF mode sub scanning direction magnification ratio in FAX:
                                              Copy  quantity  keys
AR-205
7 – 10
Page of 14
Display

Click on the first or last page to see other AR-205 (serv.man10) service manuals if exist.