DOWNLOAD Sharp AR-200 (serv.man5) Service Manual ↓ Size: 153.55 KB | Pages: 23 in PDF or view online for FREE

Model
AR-200 (serv.man5)
Pages
23
Size
153.55 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR200 Service Manual
File
ar-200-sm5.pdf
Date

Sharp AR-200 (serv.man5) Service Manual ▷ View online

Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
22
16
Duplex print counter
display
Used to display the current duplex print counter value. 
1
17
Copy counter display
Used to display the current copy counter value. 
1
18
Printer counter display
Used to display the current printer counter value. 
1
19
Electronic sort counter
display
Used to display the current electronic sort counter value. 
1
20
FAX print counter display
Used to display the current FAX print counter value. 
1
21
Scanner counter display
Used to display the current scanner counter value.
24
1
JAM memory, JAM
counter clear
Used to clear the JAM memory and the JAM counter. 
2
2
Trouble memory clear
Used to clear the trouble memory. 
2
4
SPF counter clear
Used to clear the SPF counter. 
2
5
Duplex counter clear
Used to clear the duplex counter. 
2
6
Paper feed counter clear
Used to clear the paper feed counter. 
2
7
Drum counter clear
Used to clear the drum counter. 
2
8
Copy counter clear
Used to clear the copy counter. 
2
9
Printer counter clear
Used to clear the printer counter. 
2
10
Electronic sort counter
clear
Used to clear the electronic sort counter. 
2
11
FAX print counter clear
Used to clear the FAX print counter. 
2
13
Scanner counter clear
Used to clear the scanner counter. 
2
25
1
Main motor operation
check
Execute the simulation with the developer cartridge removed, and the
main motor will rotate for 30 sec. At that time, the cooling motor rotates
at a low speed.
10
Polygon motor operation
check
Used to drive the polygon motor for 30 sec.
26
1
Option switch display
Used to display the installed option on the operation panel. (The LED
corresponding to the installed option is lighted.)
Key operation
Display
Display select: 
  Magnification 
ratio
display key
<Lighting with an option installed>
When “A” is displayed:
Shifter: Paper empty LED
Job separator: JAM LED
SPF: SPF select LED
RSPF: SPF JAM LED
Duplex mode: Main cassette select LED
Simplex mode: Multi manual paper feed select LED
When “b” is displayed:
Cassette (2nd step): No. 2 cassette select LED
Cassette (3rd step): No. 3 cassette select LED
Cassette (4th step): No. 4 cassette select LED
Memory installed: Paper empty LED
FAX: JAM LED
Printer: Main body JAM LED
ERDH: Main cassette select LED
16CPM: SPF JAM LED
20CPM: SPF select LED
Document sensor: Auto paper select LED
3
Auditor setting
Used to display the current auditor setting with the numbers at right. 
After entering the set value, press the start key, and the set value is
stored.
0
 2
Key operation/Display
0: Built-in auditor
1: Coin vendor
2: Others
1: Each counter display method
To display 123456: 123 (0.75 sec) 
 Blank (0.35sec) 
 456 (0.75 sec) 
 Blank (1.0 sec) 
 repetition
2: Display after clearing each counter 
000 (0.75 sec) 
 Blank (0.35sec) 
 000 (0.75 sec) 
 Blank (1.0 sec) 
 Repetition
AR-200
5 – 6
Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
26
5
Counter mode setting
Used to set the print counter mode in A3 or 11" 
×
 17".
Used to display the currently set counter value with the numbers at right.
After entering the set value, press the start key, and the set value is
stored.
0
 3
Key operation/Display
0: Total/Developer = 2 counts
Maintenance = 2 counts
1: Total/Developer = 1 count
Maintenance = 2 counts
2: Total/Developer = 2 counts
Maintenance = 1 count
3: Total/Developer = 1 count
Maintenance = 1 count
6
Destination setting
Used to display the current destination setting with the numbers at right.
After entering the set value, press the start key, and the set value is
stored.
0
 11
Key operation/Display
 0: Japan
  1: USA (Inch series)
  2: Canada (Inch series)
  3: Germany (AB series)
  4: UK (AB series)
  5: Australia (AB series)
  6: France (AB series)
  7: EX inch series
  8: EX AB series
  9: EX inch series (FC conformity)
10: EX AB series (FC conformity)
11: Taiwan, China (AB series)
10
Model name setting
Used to set the model name of the machine used with the following
numbers. After entering the set value, press the start key and the set
value is stored.
0
 12
Key operation/Display
 0: AL-1600
 1: AL-1610
 2: AL-1620
 3: AL-1640/AL-1641
  4: AR-160/AR-S160
  5: AR-161/AR-S161
 6: AR-200S
  7: AR-200/AR-S200
  8: AR-205/AR-S205
 9: AR-F160
10: AR-F205
11: AR-N200
12: AR-N205
22
Language setting
Used to display the current setting of the language information with the
number at right. After entering the set value, press the start key, and the
set value is stored.
0
 7
Key operation/Display
0: Japanese
1: English
2: French
3: German
4: Italian
5: Dutch
6: Swedish
7: Spanish
1: Each counter display method
To display 123456: 123 (0.75 sec) 
 Blank (0.35sec) 
 456 (0.75 sec) 
 Blank (1.0 sec) 
 repetition
2: Display after clearing each counter 
000 (0.75 sec) 
 Blank (0.35sec) 
 000 (0.75 sec) 
 Blank (1.0 sec) 
 Repetition
AR-200
5 – 7
<Only models with the
document detection
function is installed>
Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
26
30
CE mark conformity
control setting
Used to display the current setting of CE mark conformity control with the
number at right. After entering the set value, press the start key, and the
set value is stored.
0
 1
Key operation/Display
0: CE mark control OFF
1: CE mark control ON
38
Cancel of stop at drum life
over
The currently set value is displayed. After entering the set value, press
the start key to store the set value.
1
 1
Key operation/Display
0: The machine stops at drum life over.
1: The machine does not stop at drum life over.
42
Transfer timing adjustment
After completion of warm up, shading is performed and the currently set
transfer timing adjustment value is displayed.
5
1, 3, 5, 7, 9
Key operation
Transfer timing adjustment value: 10-key
"1": 240ms
"3": 260ms
"5": 280ms
"7": 300ms
"9": 320ms
30
1
Machine sensor operation
check
Used to check the sensors in the machine transport system with LED on
the operation panel.
Display
<Lighting at sensor ON>
Paper entry sensor: Machine position JAM LED
Duplex sensor: SPF JAM LED
Paper exit sensor: JAM LED
No. 2 cassette transport sensor: No. 2 cassette position LED
No. 3 cassette transport sensor: No. 3 cassette position LED
No. 4 cassette transport sensor: No. 4 cassette position LED
drum initial SW: DRUM LED
41
2
OC document sensor
adjustment
<Only models with the
document detection
function is installed>
Used to read the document sensor input value with paper and perform
the sensor detection level adjustment. For the adjustment procedure of
the document sensor input value, refer to the previous descriptions.
3
Document sensor light
reception level display
Used to display the light reception level and the detection level of the
document sensor. (The sensor level adjusted with SIM 41-2 is dis-
played.)
Key operation
Display
Light reception/Detection
level select: Magnification
ratio display key
Display at the 3rd digit
“A”:
Light reception level display
“b”:
Document detection level
display
Sensor select: Auto
magnification ratio select key
Sensor A: A3 (11 
×
 17) document
size LED
Sensor B: A4 (8 1/2 
×
 14) document
size LED
Sensor C: A4R (8 1/2 
×
 11) document
size LED
Sensor D: B4 (8 1/2 
×
 5 1/2)
document size LED
42
1
Developing counter clear
Used to clear the Developing counter. 
2
2: Display after clearing each counter 
000 (0.75 sec) 
 Blank (0.35sec) 
 000 (0.75 sec) 
 Blank (1.0 sec) 
 Repetition
AR-200
5 – 8
<Only when the FAX is
installed>
Main
code
Sub
code
Contents
Details of operation
Initial
value
Set range
43
1
Fusing temperature setting
Used to display the current setting of the fusing temperature at right.
After selecting the fusing temperature with the magnification ratio display
key, press the start key, and the set value is stored. The set range is 155
 190˚C. Use the magnification ratio key to adjust the value by –5˚C.
180
155 
 190
Key operation
Fusing temperature select: Magnification ratio display key
46
1
Copy density level
adjustment
After completion of warmup, shading is performed and the currently set
copy density level is displayed. For the adjustment procedure, refer to
the previous descriptions.
 99
Key operation
Display
Mode select: Exposure mode
select key
Copy density level: Numeric
keys
<LED lighting at each mode selection>
Auto mode: AUTO LED
Manual mode: MANUAL LED
Photo mode: PHOTO LED
Toner save mode: MANUAL +
PHOTO LED
AETS mode: AUTO + PHOTO LED
2
FAX density level
adjustment
After completion of warmup, shading is performed and the currently set
FAX density level is displayed. For the adjustment procedure, refer to the
previous descriptions.
 99
Key operation
Display
Mode select: 
Exposure mode select
key
Fax density level:
Numeric key
<LED lighting at each mode selection>
Standard mode: Standard LED
Fine mode: 
 FINE 
LED
Super fine mode: SUPER FINE LED
Ultra fine mode: Ultra fine LED
Half tone mode: HALF TONE LED
48
1
Main scanning (front/rear)
direction magnification
ratio adjustment
(Copy/FAX/OC-SPF
common)
After completion of warmup, shading is performed and the currently set
main scanning (front/rear) direction magnification ratio adjustment and
the OC mode document center off adjustment are performed. For the
adjustment procedure, refer to the previous descriptions.
 99
Key operation
Display
Adjustment mode select:
Magnification ratio display
key
Auto magnification ratio adjustment:
 AUTO 
LED
Manual main scanning
direction magnification
ratio adjustment
Set value: Numeric keys
Manual magnification ratio adjustment:
 MANUAL 
LED
OC mode document center off
adjustment:
 PHOTO 
LED
2
OC mode sub scanning
direction magnification
ratio adjustment in copying
After completion of warmup, shading is performed and the currently set
OC mode sub scanning direction magnification ratio adjustment in copy-
ing is performed. For the adjustment procedure, refer to the previous
descriptions.
 99
Key operation
OC mode sub scanning direction magnification ratio in copying:
Numeric keys
1: Each counter display method
To display 123456: 123 (0.75 sec) 
 Blank (0.35sec) 
 456 (0.75 sec) 
 Blank (1.0 sec) 
 repetition
2: Display after clearing each counter 
000 (0.75 sec) 
 Blank (0.35sec) 
 000 (0.75 sec) 
 Blank (1.0 sec) 
 Repetition
AR-200
5 – 9
Page of 23
Display

Click on the first or last page to see other AR-200 (serv.man5) service manuals if exist.