6. Communication section
Note: These items are factory adjusted when shipping according to
FCC standards. Therefore, do not change the setting in the
market.
A. Dial test (<FAX mode> SIM 66-13)
(1) Dial pulse transmission test
1) Execute SIM 66-13 in FAX mode.
2) Execute the dial pulse mode according to the instructions on the
LCD display.
SELECT SIGNAL
1:PULSE  2:DTMF
3) Set the make time.
INPUT MAKE TIME
(0–15)              
4) Select the dial to be transmitted.
Default: 0123456789#
(After deleting with the clear key, it can be set to any desired
value.)
5) Transmission is started from the line.
SEND yyPPS xxm s
1:YES 2:NO
SENDING yyPPS xxm s
SIM
Soft SW
Initial
value
Set value
Dial
pulse
make
time
10
PPS
FAX
mode
66-13
SW67-
1 – 4
40ms
(14)
SW set value:
0 – 15
Make time:
25 – 41ms
1ms
step
(Binary
input)
(2) DTMF signal transmission level adjustment
1) Execute SIM 66-13 in the FAX mode.
2) Execute the DTMF mode according to the instructions on the
LCD display.
SELECT SIGNAL
1:PULSE  2:DTMF
3) Select the signal transmission level.
The signal transmission level is classified into two groups: the
high group, and the low group.
Transmission can be made with either of default and the soft
SW set value.
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
4) The transmission level can be set when the following menu is
displayed on the LCD. (et value 1 = 0.5dB change)
INPUT VALUE
(0–15)              
(This value is returned to the original value when the simulation
mode is canceled.)
5) Select the dial signal to be transmitted.
Default: 0123456789#
(After deleting with the clear key, it can be set to any desired value.)
6) Start transmission from the line.
H:xx   L:yy
1:YES 2:NO
SENDING DTMF
xx: High group soft SW set value
yy: Low group soft SW set value
SIM
Soft SW
Initial
value
Set value
DTMF
trans-
mission
level
High
group
(FAX
mode)
66-13
(Test
only)
SW53-
1 – 4
3.5dB
(7)
SW set
value: 0 –
15
Transmis-
sion level: 0
– 7.5db
0.5ms
step
(Binary
input)
Low
group
SW53-
5 – 8
3.5dB
(7)
AR-F152
8 – 12
[9] SIMULATION, FAX SOFTWARE SWITCH, TROUBLE CODES
1. List of simulations
The simulations for the AR-F152 (with Fax functions) are shown in bold fonts.
Sim
No.
Kind of
main code
Sub
code
Operation
01
Optical
system
01
Mirror scan operation
02
SPF
Individual
load
operation
02
03
04
05
06
07
SPF sensor status display
Motor ON
Paper feed solenoid ON
Pressure release solenoid ON
(RSPF)
Resist clutch ON (RSPF)
Gate solenoid ON (RSPF)
05
Lamp ON
check
01
02
03
Operation panel display check
Fusing lamp ON + Cooling fan
HIGH/LOW speed
Copy lamp ON
06
Machine
individual
load
operation
01
02
Paper feed solenoid ON
Resist solenoid ON
07
Aging
01
06
Warm up display and aging with
jam
Intermittent aging
08
High
voltage
output check
01
02
03
06
Developing bias
Main charger (Grid high)
Grid voltage (Low)
Transfer charger
10
Other
None
Toner motor aging
14
Trouble
reset
None
Cancel troubles other than U2
16
U2 trouble
reset
None
Cancel of U2 trouble
20
Maintenance 
counter
clear
01
Maintenance/mini-maintenance
counter clear
21
Counter
setup
(When
maintenance)
01
02
Maintenance cycle setup
Mini-maintenance cycle setup
22
Counter
display
01
02
04
05
06
08
12
14
17
18
20
21
22
23
24
Maintenance/mini-maintenance
counter display
Maintenance/mini-maintenance
preset display
Jam total counter display
Total counter display
Developer counter display
SPF counter display
Drum counter display
P-ROM version display
Copy counter display
Printer counter display
FAX print counter display
Scanner counter display
SPF jam total counter display
FAX reception counter display
FAX transmission counter
display
24
Special
counter
clear
01
04
06
07
08
09
10
11
13
14
Jam total counter clear
SPF counter clear
Developer counter clear
Drum counter clear
Copy counter clear
Printer counter clear
FAX transmission/reception
counter clear
FAX print counter clear
Scanner counter clear
SPF jam total counter clear
25
Main motor
ON
01
10
Main motor system ON + Cooling
fan low speed (For the duplex
model, the duplex motor is
simultaneously turned on.)
Polygon motor ON
Sim
No.
Kind of
main code
Sub
code
Operation
26
Various
setup
01
02
03
04
06
07
20
30
37
39
40
42
43
44
47
55
Manual feed setup
SPF setup
Second cassette setup
Machine duplex setup
Destination setup
Machine conditions check
Rear edge void setup
CE mark conformity control
ON/OFF setup
Cancel of stop at developer over
Memory capacity setup
Polygon motor OFF time setup
Transfer ON timing control setup
Side void setup
SPF document rear edge read
setup
FAX document rear edge scan
setup
CRUM destination display
30
Sensor
operation
check
(Standard
provision)
01
Paper sensor status display
43
Fusing
temperature
setup
01
04
05
09
Normal copy
Fusing temperature setup 2
Duplex mode fusing temperature
setup
Postcard size paper fusing control
setup
46
Exposure
adjustment
01
12
13
14
15
19
Copy density adjustment
FAX density overall adjustment
FAX density adjustment
(Standard mode)
FAX density adjustment (Fine
character mode)
FAX density adjustment (Super
Fine mode)
γ
 Table adjustment (Copy mode)
48
Magnification 
ratio
correction
01
Front/rear scan direction
50
Lead edge
adjustment
01
10
18
19
Lead edge image position
adjustment
Paper lead edge/rear edge void
adjustment
Paper center offset +
OC/Document center offset +
SPF document center offset
Memory reverse position
adjustment
Duplex copy rear edge void
adjustment
51
Timing
adjustment
02
06
Resist quantity adjustment
SPF exposure correction
61
Laser
system
operation
03
Polygon motor check
(HSYNC output check)
63
Shading
01
Shading check
64
Self print
01
Self print only with the engine (1
by 2 mode)
66
FAX PWB
check
None
Simulation on the FAX panel
(For details, refer to the FAX
simulation.)
67
Program
Download
14
PCL PWB program download
AR-F152
9 – 1
2. Contents of simulations (new or revised simulations only)
Input method: Clear key 
 Exposure Select key 
 Clear key 
 Exposure Select key
Main code
Sub code
Content
01
01
Mirror scan operation
(Operation/Procedure)
1.   When this simulation is executed, the mirror home position is detected.
2.
When the _START key is pressed, scanning is executed at the speed corresponding to the currently set copy
magnification ratio.
The copy magnification ratio can be arbitrarily set with the magnification ratio select key/zoom key.
02
02
SPF sensor status display
ON/OFF of the sensors in the SPF can be checked with the following lamps.
03
Motor ON
(Operation/Procedure)
When the start key is pressed, the SPF motor rotates for 10 sec at the speed corresponding to the currently set
magnification ratio.
04
Paper feed solenoid ON
(Operation/Procedure)
When the start key is pressed, the SPF paper feed solenoid repeats ON (500 ms) and OFF (500 ms) 20 times.
05
Pressure release solenoid ON (RSPF)
(Operation/Procedure)
When the start key is pressed, the RSPF document transport solenoid (SPFS) repeats ON (500 ms) and OFF
(500 ms) 20 times.
06
Resist clutch ON (RSPF)
(Operation/Procedure)
When the start key is pressed, the RSPF resist clutch (SRRC) repeats ON (500 ms) and OFF (500 ms) 20
times.
07
Gate solenoid ON (RSPF)
(Operation/Procedure)
When the start key is pressed, the RSPF gate solenoid (SGS) repeats ON (500 ms) and OFF (500 ms) 20
times.
05
01
Operation panel display check
When the PRINT switch is pressed, the LED on the operation panel is lighted for 5 sec. The LED on the FAX
panel and the LCD black background are displayed simultaneously.
02
Fusing lamp ON + cooling fan HIGH/LOW speed
(Operation/Procedure)
When the START key is pressed, the fusing lamp repeats ON (500ms) and OFF (500msec) 5 times.
During this period, the cooling fan rotates in the high speed mode. After completion of the operation, the cooling
fan rotates in the low speed mode.
03
Copy lamp ON
(Operation/Procedure)
When the START key is pressed, the copy lamp is lighted for 5 sec.
06
01
Paper feed solenoid ON
(Operation/Procedure)
When the START key is pressed, the paper feed solenoid selected by the tray select key repeats ON (500ms)
and OFF (500ms) 20 times.
02
Resist solenoid ON
(Operation/Procedure)
When the START key is pressed, the resist solenoid (RRS) repeats ON (500ms) and OFF (500ms) 20 times.
Sensor name
Display lamp
Mirror home position sensor
OPC drum cartridge replacement lamp
Display
Sensor
Toner cartridge replacement lamp
Document set detection (SPID)
Jam lamp
SPF document transport detection (SPPD)
Developer replacement lamp
SPF cover open detection (SCOD)
SPF jam lamp
SPF open/close detection (SDSW)
FAX document size detection
Paper size detection
SPF lamp
FAX/SPF B4 size detection (SB4D)
AR-F152
9 – 2
Main code
Sub code
Content
07
01
Warm-up display and aging with jam
(Operation/Procedure)
1. When the simulation is executed, warming up is started.
2. Warm-up time is counted and displayed every second on the copy quantity display.
3. After completion of warm-up, the time count is stopped and the ready lamp is lighted.
4. Press the clear key to clear the warm-up time display, set the copy quantity, and press the START key, and
the machine will copy the set quantity repeatedly.
06
Intermittent aging
(Operation/Procedure)
1. When the simulation is executed, warming up is started.
2. After completion of warm-up, the ready lamp is lighted.
3. Set the copy quantity and press the START key, and the machine will copy the set quantity repeatedly.
4. After 3 sec of the interval time from completion of copying the set quantity, the machine will resume copying.
5. The above operation 4 is repeated.
08
01
Developing bias
(Operation/Procedure)
When the START key is pressed, the developing bias is outputted for 30 sec.
02
Main charger (Grid high)
(Operation/Procedure)
When the START key is pressed, the main charger output is supplied for 30 sec in the grid voltage HIGH mode.
03
Grid voltage (Low)
(Operation/Procedure)
When the START key is pressed, the main charger output is supplied for 30 sec in the grid voltage LOW mode.
06
Transfer charger
(Operation/Procedure)
When the START key is pressed, the transfer charger output is supplied for 30 sec.
10
None
Toner motor aging
(Operation/Procedure)
When the START key is pressed, the toner motor output is supplied for 30 sec.
14
None
Cancel of troubles other than U2
(Operation/Procedure)
After canceling the trouble, the simulation is also automatically canceled.
16
None
Cancel of U2 trouble
(Operation/Procedure)
1. When the START key is pressed, the EEPROM total counter check sum is rewritten and the trouble is
canceled.
2. After canceling the trouble, the simulation is also automatically canceled.
20
01
Maintenance/mini-maintenance counter clear
When the Print switch is pressed, the maintenance counter is cleared, and 000000 is displayed. When the
destination has been set to Japan AB series, the mini-maintenance counter is cleared.
21
01
Maintenance cycle setup
The currently set maintenance cycle code is displayed (initial display), and the set data is stored.
02
Mini-maintenance cycle setup (Valid only when the destination is set to Japan AB series.)
The current set code of maintenance cycle is displayed (Initial display), and the set data is stored.
Code
Setup
0
3,000 sheets
1
6,000 sheets
2
9,000 sheets
3
13,000 sheets
4
25,000 sheets
5
Free (999,999 sheets) 
 Default
Code
Setup
0
5,000 sheets   
 Default
1
10,000 sheets
2
Free (999,999 sheets)
AR-F152
9 – 3
Page of 127