Sharp AR-122E Handy Guide ▷ View online
Options
Version 1.0
Issue 08/02
5
SHARP ELECTRONICS (UK) LTD
COPIER TECHNICAL SUPPORT
DOCUMENT SOLUTIONS GROUP
Options
AL12PKM – GDI /Scanner Expansion Kit
This is an IEEE1284 parallel and a USB 1.1 interface. It should be noted that
scanning to a PC is only available via the USB port. Therefore, users of Windows 95
and Windows NT 4.0 will not be able to use the machine for scanning to a PC as
Windows 95 and Windows NT 4.0 do not support a USB interface.
scanning to a PC is only available via the USB port. Therefore, users of Windows 95
and Windows NT 4.0 will not be able to use the machine for scanning to a PC as
Windows 95 and Windows NT 4.0 do not support a USB interface.
Routine Maintenance
Version 1.0
Issue 08/02
6
SHARP ELECTRONICS (UK) LTD
COPIER TECHNICAL SUPPORT
DOCUMENT SOLUTIONS GROUP
DEVELOPER SET UP
The toner/developer cartridge is self setting. No set-up
procedure is required.
procedure is required.
LASER PRINT HORIZONTAL IMAGE CHECK
Sim 64 – 01 Self print
LASER PRINT & ORIGINAL OFF CENTRE
Sim 50 – 10 Centre offset adjustment
Sim 50 – 18 Duplex reverse position adjustment
Sim 50 – 19 Duplex rear edge void adjustment
Sim 50 – 18 Duplex reverse position adjustment
Sim 50 – 19 Duplex rear edge void adjustment
COPY IMAGE POSITION & VOID
Sim 50 – 01 Lead edge image position
COPY QUALITY
Sim 46 – 01 Copy density adjustment (300dpi)
Sim 46 - 02 Copy density adjustment (600dpi)
Sim 46 - 18 Image contrast adjustment (300dpi)
Sim 46 - 02 Copy density adjustment (600dpi)
Sim 46 - 18 Image contrast adjustment (300dpi)
CASSETTE SIZES
Set cassette sizes as per Service Manual page 5-3, 8.
OTHER
Sim 24 – 08 Copy Counter Clear
Sim 26 – 06 Destination Setting
Sim 25 – 01 Main motor check
Sim 26 – 06 Destination Setting
Sim 25 – 01 Main motor check
Routine Maintenance
Version 1.0
Issue 08/02
7
SHARP ELECTRONICS (UK) LTD
COPIER TECHNICAL SUPPORT
DOCUMENT SOLUTIONS GROUP
MAINTENANCE COMPLETED
Sim 20 - 01 Maintenance counter clear
Sim 24 – 08 Copy counter clear
Sim 24 – 09 Printer counter clear
Sim 24 - 13 Scanner counter clear
Sim 24 – 08 Copy counter clear
Sim 24 – 09 Printer counter clear
Sim 24 - 13 Scanner counter clear
DRUM REPLACEMENT
Sim 20 - 01 Use to clear Drum Counter
DEVELOPER REPLACEMENT
Sim 24 – 06 Developer counter clear
COPY QUALITY
Sim 46 – 01 Copy density adjustment (300dpi)
Sim 46 - 02 Copy density adjustment (600dpi)
Sim 46 - 02 Copy density adjustment (600dpi)
JAM & TROUBLE COUNTER
Sim 14 Cancel of troubles other than U2
Sim 16 Cancel of U2 troubles
Sim 24 – 01 Jam counter clear
Sim 16 Cancel of U2 troubles
Sim 24 – 01 Jam counter clear
Machine Settings and
Adjustments
Version 1.0
Issue 08/02
8
SHARP ELECTRONICS (UK) LTD
COPIER TECHNICAL SUPPORT
DOCUMENT SOLUTIONS GROUP
SECTION
ADJUSTMENT ITEM
ADJUSTMENT
PROCEDURE
Process
1 Developer bias check
Sim 8-1 (-400v)
2 Grid bias check
Sim 8-2/3 (400 / 580v)
Laser scanner
1 Front/rear magnification
Sim 48 – 01
2 Print off centre
Sim 50-10
Copy Density
1 Copy mode
Sim 46 – 01/02
Paper Transport
1 Resist Roller Buckle
Sim 51-2
Click on the first or last page to see other AR-122E service manuals if exist.