DOWNLOAD Sharp AL-800 (serv.man7) Service Manual ↓ Size: 103.42 KB | Pages: 22 in PDF or view online for FREE

Model
AL-800 (serv.man7)
Pages
22
Size
103.42 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AL800 840 Service Manual-Simulation codes
File
al-800-sm7.pdf
Date

Sharp AL-800 (serv.man7) Service Manual ▷ View online

Operation/
Procedure
1) The currently set code of the scanner (writing) motor OFF timing after completion of printing is displayed.
2) To change the set content, enter the code of your desired setting and press the start button.
Setting code
Scanner (writing) motor OFF timing
0
 
0  sec
1
30 sec
2
60 sec
3
90 sec
Note
30
30 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the sensors and detectors in the paper feed section, the paper transport section,
and the paper exit section and their control circuit.
Section
Item
Operation
Operation/
Procedure
The paper detectors operations can be checked with lighting of the lamps on the operation panel.
Detector name
Monitor lamp
Paper empty detector
PE SENSOR
Developer cartridge replacement lamp
Paper entry detector
PIN SENSOR
Paper jam lamp
Paper exit detector
POUT
Photoconductor cartridge replacement lamp
Paper size (width) detector
PAPER SIZE SW
Zoom lamp
Note
43
43 - 1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature.
Section
Fixing (Fusing)
Item
Operation
Operation/
Procedure
1) The currently set code of the fusing temperature (normal state) is displayed.
2) To change to the standard set temperature, press the code corresponding to the standard set temperature and
press the start button.
Be sure to set to "0" (160°C). 
If set to other than "1," a trouble may occur.
Set code
Fusing temperature (°C)
0
160
1
150
2
155
3
165
4
170
5
175
Note
Be sure to set to the specified value (default).
43 - 4
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature after 20th sheet in the multi print mode.
Section
Fixing (Fusing)
Item
Operation
8 – 17
Operation/
Procedure
1) The currently set code of the fusing temperature (after 20th sheet of continuous printing) is displayed.
2) To change to the standard set temperature, press the code corresponding to the standard set temperature and
press the start button. 
Be sure to set to "2" (155°C). 
If set to other than "1," a trouble may occur.
Set code
Fusing temperature (°C)
0
160
1
150
2
155
3
165
4
170
5
175
Note
If not, a trouble may occur.
46
46 - 1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy density.
(The print density in each mode and the overall print density (overall setting of the specified density gradient) can
be adjusted.
Section
Item
Picture quality
Density
Operation/
Procedure
By adjusting the exposure level of the center density, the other copy density levels (density levels 1, 2, 4, 5) can
be automatically calculated and adjusted. 
The gamma curve (gradient) is fixed and cannot be changed. By changing the adjustment value, however, the
gamma curve is shifted (with the fixed gradient). 
Therefore, the overall copy density is changed. 
The above adjustment is made for each copy mode. 
Each copy mode and each copy density level (5 steps) have their own gamma curve (gradient). The adjustment
value can be set in the range of 0 ~ 99.
1) Select the picture quality mode with the copy picture quality mode select key. 
(The currently set copy density adjustment level is displayed on the copy quantity display.)
2) To change the copy density, change the adjustment value and press the start button. 
(The adjustment value is stored and a copy is made.)
To decrease the copy density, decrease the adjustment value, and vice versa.
Adjustment mode
Mode display lamp
Density 
level
Density (Test chart UKOG-0162FCZZ gray scale
density level)
Auto copy mode
Auto copy mode lamp
Gray scale "3" is slightly copied.
Manual copy mode
Text copy mode lamp
3
Gray scale "3" is slightly copied.
Photo copy mode
Photo copy mode lamp
3
Gray scale "3" is slightly copied.
Auto (Toner save)
copy mode
Auto copy mode lamp
Gray scale "3" is slightly copied.
Photo copy mode lamp
Manual (Toner save)
copy mode
Manual copy mode
lamp
3
Gray scale "3" is slightly copied.
Photo copy mode lamp
Note
48
48 - 1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the coy magnification ratio (in the main scanning direction and the sub scanning direction).
Section
Item
Picture quality
8 – 18
Operation/
Procedure
There are following three copy magnification ratio adjustment modes.
Adjustment mode
Adjustment mode display (ON)
Note
Main scanning direction
Auto
Auto copy mode lamp
Automatically adjusted by the software.
Manual
Manual copy mode lamp
Automatically adjusted by the software.
Sub scanning direction
Manual
Photo copy mode lamp
Adjustment is made by changing the
scanning speed,
1) Select the adjustment mode with the copy picture quality mode select key. 
(The currently set copy density adjustment level is displayed on the copy quantity display.)
2) To change the copy magnification ratio, change the adjustment value and press the start button. 
(The adjustment value is stored and a copy is made at the copy magnification ratio corresponding to the value.)
The adjustment value can be set in the range of 0 ~ 99.
In the case of the main scanning direction copy magnification ratio adjustment (auto) mode, the adjustment is
made automatically and there is no need to adjust. Without entering the adjustment value, press the start
button. 
There are two marks on the shading correction plate, and the distance between the two marks is read by the
CCD to adjust the main scanning direction copy magnification ratio automatically. In case of the mark reading
error, "- - -" is displayed on the copy quantity display. 
At that time, the main scanning direction image position adjustment is also made automatically. 
If, however, automatic adjustment is not made, manual adjustment must be made.
When the adjustment value is changed by "1," the copy magnification ratio is changed by 0.1%.
Note
50
50 - 1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy image position o the print paper in the copy mode and to adjust the void area (image
loss).
Section
Item
Picture quality
Operation/
Procedure
There are following four adjustment items.
By changing the adjustment values of the items, the paper lead edge, the rear edge, image loss, and void area
can be adjusted.
Adjustment item
Adjustment mode
display (ON)
Note
Image lead edge
position (print start
position)
Auto copy mode lamp
Used to determine the relative positions of the paper and the
image. The paper lead edge and the image lead edge reference
position (image lead edge) are aligned. (It corresponds to the time
from when the PIN detector detects the paper lead edge to when
the scanner starts (printing is started).
Image lead edge
reference position
(image scan start
position)
Photo copy mode lamp
Used to determined the image lead edge reference position.
(Used to determine the distance between the scanner home
position to the document lead edge reference position.)
Lead edge void area
Manual copy mode
lamp
Used to adjust the lead edge section effective image amount. The
images scanned from starting the scanner to reaching the image
lead edge reference position and during the time corresponding to
this setting are made invalid (cut off) to make the image loss and
the void area.
Rear edge void area
Auto/Photo/Manual
copy mode lamp
Used to determine the cut timing of the print image (data). The
PIN detector detects the paper length. The print image (data) cut
timing is determined from the relationship between the calculated
paper length and the sub scanning direction image length,
1) Select the adjustment mode image lead edge position (print start position) with the copy picture quality mode
select key.
(The currently set adjustment value is displayed on the copy quantity display.)
2) Change the set value and press the start button. 
(The adjustment value is stored and a copy is made.)
When the set value is made greater, the image lead edge position is shifted forward for the paper lead edge
position.
When the set value is made smaller, the image lead edge position is shifted backward for the paper lead
edge position.
3) Select the adjustment mode image lead edge position (image scanning start position) with the copy picture
quality mode select key.
(The currently set adjustment value is displayed on the copy quantity display.)
8 – 19
4) Change the set value and press the start button.
When the set value is made greater, the image lead edge reference position is shifted forward.
When the set value is made smaller, the image lead edge reference position is shifted backward.
(Note) If this adjustment is not made properly, when the copy magnification ratio is changed, the copy image position
varies for the paper lead edge position.
5) Select the adjustment mode lead edge void area with the copy picture quality mode select key. (The currently
set adjustment value is displayed on the copy quantity display.)
6) Change the set value and press the start button. 
7) Select the adjustment mode rear edge void area with the copy quality mode select key.
(The currently set adjustment mode is displayed on the copy quantity display.)
8) Change the set value and press the start button. 
The adjustment value can be set in the range of 0 ~ 99.
Note
50 - 10
Purpose
Adjustment
Function
(Purpose)
Used to adjust the main scanning direction print image position. (Main scanning direction void area adjustment)
Section
ICU
Item
Picture quality
Operation/
Procedure
1) Select the adjustment item with the copy image mode select key.
Adjustment mode
Adjustment mode display (ON)
Note
Main scanning direction image
position
Photo copy mode lamp
Main scanning direction image
position (SPF mode)
Auto/Photo/Manual copy mode lamp
Left void area
Auto copy mode lamp
Right void area
Manual copy mode lamp
2) To change the copy image position in the main scanning direction for the paper in a copy mode (to change
the main scanning direction void area), change the adjustment value and press the start button. 
(The adjustment value is stored and a copy is made corresponding to the setting.)
The adjustment value can be set in the range of 0 ~ 99.
When the adjustment value is changed by "1," the copy image position is shifted by 0.1mm in the main
scanning direction for the paper. 
When the main scanning direction copy magnification ratio is adjusted with SIM 48-1 (auto mode), this
adjustment is automatically performed and there is no need to enter the adjustment value with this simulation.
If the adjustment is not made properly, use this simulation to make a manual adjustment. (Except for the SPF
mode. In the case of the SPF mode, the adjustment with this simulation is required.)
3) To change the left and the right void areas, select the adjustment mode, change the adjustment value and
press the start button. 
(The adjustment value is stored and a copy corresponding to the setting is made.)
The adjustment value can be set in the range of 0 ~ 99.
When the adjustment value is changed by "1," the void area is changed by 0.1mm,
Note
61
61 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the scanner (writing) section.
Section
Laser (Exposure)
Item
Operation
Operation/
Procedure
While laser beams are outputted, the scanner(writing) motor rotates for 30 sec.
At that time, the zoom mode display lamp lights up for 100msec every time when the laser beam sensor detects
laser beam,
Note
8 – 20
Page of 22
Display