DOWNLOAD Sharp AL-2021 Service Manual ↓ Size: 12.48 MB | Pages: 120 in PDF or view online for FREE

Model
AL-2021
Pages
120
Size
12.48 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual
File
al-2021.pdf
Date

Sharp AL-2021 Service Manual ▷ View online

AL-2041  SIMULATION, TROUBLE CODES  10 - 13
46
01
Copy density adjustment 
(300dpi)
[Function]
Copy density is set for each mode.
When this simulation is executed, the current set value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to make a copy under the set value.
When the set value is increased, the copy becomes darker. When the set value is decreased,
the copy becomes lighter.
In this case, only Exp.3 copy is made. When, however, the setting is made to make darker copy,
Exp.1 and Exp.5 copies also become darker. When made to lighter copy, Exp1. and Exp.5 cop-
ies become lighter, too.
Press [Exposure mode selector] key to switch the mode. The set value of the selected mode is
displayed on the LCD/display. (Adjustment value: 1 – 99) 
The setting procedure of the magnification ratio is the same as that to copy operation.
[Operation]
1) Press [Exposure mode selector] key to change the mode. 
2) Press [ ] [ ] key to set the value. 
3) [START] Fixing and printing value
∗ Print is started in the set mode.
∗ To cancel the manual paper feed tray paper empty MSG, press [Any] key. 
∗ When the AE mode exposure adjustment is made, put the chart on the rear side of the 
document table to avoid the center section (10cm).
02
Copy density adjustment 
(600dpi)
[Function]
Copy density is set for each mode.
When this simulation is executed, the current set value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to make a copy under the set value.
When the set value is increased, the copy becomes darker. When the set value is decreased,
the copy becomes lighter.
In this case, only Exp.3 copy is made. When, however, the setting is made to make darker copy,
Exp.1 and Exp.5 copies also become darker. When made to lighter copy, Exp1. and Exp.5 cop-
ies become lighter, too.
Press [Exposure mode selector] key to switch the mode. (Adjustment value: 1 – 99) 
[Operation]
The operation is similar to simulation 46-01.
Main 
code
Sub 
code
Contents
Details of function/operation
Mode
Display lamp
Default
AE mode (300dpi)
AE mode lamp
50
TEXT mode (300dpi)
TEXT mode lamp
50
PHOTO mode
PHOTO mode lamp
50
TS mode (TEXT) (300dpi)
TEXT mode lamp
PHOTO mode lamp
50
TS mode (AE) (300dpi)
AE mode lamp
PHOTO mode lamp
50
Dither mode
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
50
Mode
Display lamp
Default
AE mode (600dpi)
AE mode lamp
50
TEXT mode (600dpi)
TEXT mode lamp
50
PHOTO mode
PHOTO mode lamp
50
TS mode (TEXT) (600dpi)
TEXT mode lamp
PHOTO mode lamp
50
TS mode (AE) (600dpi)
AE mode lamp
PHOTO mode lamp
50
Dither mode
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
50
AL-2041  SIMULATION, TROUBLE CODES  10 - 14
46
18
Image contrast adjustment 
(300dpi)
[Function]
Contrast is set for each mode.
When this simulation is executed, the current set value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to make a copy under the set value.
When the set value is increased, the contrast becomes higher. When the set value is
decreased, the contrast becomes lower.
In this case, only Exp.3 copy is made. When, however, the setting is made to make higher con-
trast, Exp.1 and Exp.5 copies also become in higher contrast. When made to a lower contrast,
Exp1. and Exp.5 copies become lower contrast, too.
Press [Exposure mode selector] key to switch the mode. The set value of the selected mode is
displayed on the LCD/display. 
(Adjustment value: 1 – 99)
[Operation]
The operation is similar to simulation 46-01.
19
Exposure mode setup 
(AE mode)
[Function]
<
γ
 table setting>
When this simulation is executed, the code number of the current set gamma table is displayed.
(Default: 2)
Enter the code number corresponding to the desired gamma table, and press [Exposure mode
selector] key to change the mode and write into the EEPROM.
<AE operation mode>
When setting the 
γ
 table, press [Exposure mode selector] key to change to the AE operation
mode, and the current set code number of the AE operation mode is displayed. (Default: 0)
Enter the code number corresponding to the desired AE operation mode and press [Exposure
mode selector] key to change the mode and write into the EEPROM.
 
<PHOTO image process setting>
When [Exposure mode selector] key is pressed in AE operation mode setting, the mode is
changed to the PHOTO image process setting and the code number of the current set PHOTO
image process setting is displayed. (Default: 1)
Enter the code number corresponding to the desired PHOTO image process setting and press
[Exposure mode selector] key to change the mode and write into the EEPROM.
[Operation]
The operation is similar to simulation 46-01.
Main 
code
Sub 
code
Contents
Details of function/operation
Mode
Display lamp
Default
AE mode (300dpi)
AE mode lamp
50
TEXT mode (300dpi)
TEXT mode lamp
50
PHOTO mode
PHOTO mode lamp
50
TS mode (TEXT) (300dpi)
TEXT mode lamp
PHOTO mode lamp
50
TS mode (AE) (300dpi)
AE mode lamp
PHOTO mode lamp
50
Dither mode
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
50
Mode
Display lamp
Code 
number
Setting content
Remark
γ
 OFF
1
Image quality priority mode
2
Toner consumption priority mode Default
AE  
AE  
0
Lead edge stop
Default
1
Real time process
PHOTO
PHOTO
1
Error diffusion process
Default
2
Dither process
AL-2041  SIMULATION, TROUBLE CODES  10 - 15
46
20
SPF exposure correction 
(excluding AL-2021)
[Function]
Used to adjust the exposure correction amount in the SPF mode. The adjustment is made by
adjusting Vref voltage variation for the OC mode. 
When this simulation is executed, the current set value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to save the setting and make a copy. 
When the set value is increased, copy becomes darker. When the set value is decreased, copy
becomes lighter. (Adjustment range: 1 – 99)
[Operation]
The operation is similar to simulation 46-01.
29
Image contrast adjustment 
(600dpi)
[Function]
Contrast is set for each mode.
When this simulation is executed, the current set value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to make a copy under the set value.
When the set value is increased, the contrast becomes higher. When the set value is
decreased, the contrast becomes lower.
In this case, only Exp.3 copy is made. When, however, the setting is made to make higher con-
trast, Exp.1 and Exp.5 copies also become in higher contrast. When made to a lower contrast,
Exp1. and Exp.5 copies become lower contrast, too.
Press [Exposure mode selector] key to switch the mode. The set value of the selected mode is
displayed on the LCD/display. (Adjustment value: 1 – 99)
[Operation]
The operation is similar to simulation 46-01.
30
AE limit adjustment
[Function]
Used to set the limit value in AE and AE (toner save).
Change the setting and press [START] key to write the setting into the EEPROM. The machine
goes into the sub code entry standby mode.
By pressing [Exposure mode selector] key, setting is changed. 
(Setting range: 0 – 255, Default: 196)
<Remark>
When simulation 26-06 (Destination setting) or simulation 46-19 Auto Exposure mode is
changed, the setting of this simulation is also changed to the default in connection.
[Operation]
The operation is similar to simulation 46-19.
Main 
code
Sub 
code
Contents
Details of function/operation
Mode
Display item
(AL-2031/2041)
Display lamp
(AL-2031/2041)
Default
Remark
SPF
SPF
TEXT mode lamp
50
Mode
Display lamp
Default
AE mode (600dpi)
AE mode lamp
50
TEXT mode (600dpi)
TEXT mode lamp
50
PHOTO mode
PHOTO mode lamp
50
TS mode (TEXT) (600dpi)
TEXT mode lamp
PHOTO mode lamp
50
TS mode (AE) (600dpi)
AE mode lamp
PHOTO mode lamp
50
Dither mode
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
50
Mode
Display lamp
Remark
Limit value for AE (OC)
AE mode lamp
Limit value for AE (OC) 
(toner save)
TEXT mode lamp
Limit value for AE (SPF)
AE mode lamp
PHOTO mode lamp
Limit value for AE (SPF)
(toner save)
TEXT mode lamp
PHOTO mode lamp
AL-2041  SIMULATION, TROUBLE CODES  10 - 16
46
31
Image sharpness 
adjustment
[Function]
Used to adjust sharpening/blurring of image in each mode.
When this simulation is executed, warm-up and shading are performed and the current set
value is displayed. (Default: 1)
Change the set value and press [START] key to make a copy under the set conditions.
To change the mode, press [Exposure mode selector] key. The code number of the selected
mode is diplayed on the LED/display.
[Operation]
The operation is similar to simulation 46-01.
32
Copier color reproduction 
setup
[Function]
Used to set color reproduction in each mode. Colors easy to be copied and colors difficult to be
copied can be switched.
* This setting has virtually no effect on black-and-white documents.
When this simulation is executed, warm-up and shading are performed and the current set
value is displayed. (Default: 0)
Press [START] key to make a copy under the set conditions . At that time, color components are
changed for used in copying.
To change the mode, press [Exposure mode selector] key. The code number of the selected
mode is displayed on the LED/display.
[Operation]
The operation is similar to simulation 46-01.
Main 
code
Sub 
code
Contents
Details of function/operation
Image quality 
Setting No
Remark
Blurring
0
Standard
1
Default
Sharpening
2
Mode
Display lamp
Default
AE mode 
AE mode lamp
1
TEXT mode 
TEXT mode lamp
1
PHOTO mode 
PHOTO mode lamp
1
TS mode  (TEXT)
TEXT mode lamp
PHOTO mode lamp
1
TS mode  (AE)
AE mode lamp 
PHOTO mode lamp
1
Dither mode
AE mode lamp
TEXT mode lamp
PHOTO mode lamp
1
Set value
Colors easy to be copied
Colors difficult to be copied
0
Purple, Blue, Red
Yellow, Green, Water blue
1
Water blue, Green, Blue
Purple, Red, Yellow
2
Yellow, Red, Green
Blue, Water blue, Purple
Specification component
Setting No
Remark
Green
0
Default
Red
1
Blue
2
Mode
Display lamp
Default
AE mode (including TS)
AE mode lamp
0
TEXT mode (including TS)
TEXT mode lamp
0
PHOTO mode 
PHOTO mode lamp
0
Page of 120
Display