Sharp AL-1644 (serv.man14) Service Manual ▷ View online
AL-1633/1644 USER PROGRAMS 8-2
Program name
Program
No
Description
Default
Parameters
Key auto repeat
25
Use this setting to select whether or not holding down a key causes
repeated input of the key. For keys that normally cause a set value to
increase when held down (for example, holding down the [ZOOM]
key), this program can be used to have the set value not change
when the key is held down.
repeated input of the key. For keys that normally cause a set value to
increase when held down (for example, holding down the [ZOOM]
key), this program can be used to have the set value not change
when the key is held down.
ON
0 (OFF)
1 (ON)
Key press time
26
Use this setting to select how long a key must be pressed for the
input to be accepted. By selecting a longer time, you can prevent
settings from being changed by the accidental pressing of a key.
input to be accepted. By selecting a longer time, you can prevent
settings from being changed by the accidental pressing of a key.
Minimum
(current
response
speed)
1 (Minimum
(current response speed))
(current response speed))
2 (0.5sec)
3 (1.0sec)
4 (1.5sec)
5 (2.0sec)
Audible signals volume
27
This sets the volume of beep signals.
Low
(current
volume)
1 (Low (current volume))
2 (High)
3 (OFF)
Base setting beep signal
28
Use this to sound a beep when a base setting is selected.
OFF
0 (OFF)
1 (ON)
Number of copies limit
29
Use this setting to select 99 or 999 for the maximum number of
copies.
copies.
999 copies
1 (99 copies)
2 (999 copies)
Use close paper size
30
When this function is enabled, printing in printer mode will
automatically continue using a different size of paper if the specified
size of paper runs out in all trays. This feature does not function in
copy mode.
automatically continue using a different size of paper if the specified
size of paper runs out in all trays. This feature does not function in
copy mode.
OFF
0 (OFF)
1 (ON)
Default tray setting
31
Use this program to select a default tray. This tray is automatically
selected each time the power is turned on or each time the machine
reverts to the initial settings.
selected each time the power is turned on or each time the machine
reverts to the initial settings.
Tray 1
1 (Tray 1)
2 (Tray 2)
5 (Bypass tray)
Default exposure mode
32
Use this program to set "AUTO", "TEXT", or "PHOTO" as the default
exposure mode.
exposure mode.
AUTO
1 (AUTO)
2 (TEEXT)
3 (PHOTO)
[08]USERPROGRAMS.fm 2 ページ 2003年11月28日 金曜日 午前9時17分
AL-1633/1644 ELECTRICAL SECTION 12-1
[12] ELECTRICAL SECTION
1. Block diagram
Scanner Unit
CCD PWB
12V
12V
Reg
A5V 3.3V
B/
W
R
G
8bits(MSB/LSB)
B
5V
ADCCLK,SYNCH,
BSAMP,VSAMP
SDI,SCLK,LOAD,OBE
MODE
LVTTL
MCU-PWB
3.3V
IEEE 1284 I/F
USB I/F
Printer CLK(20.3094MHz)
3.3V
RIC
Download
Scanner CLK(48MHz)
A[19:1]
D[15:0]
2Mb(1Mb*2)
8Mbit
I2C Bus
Shifter
MOTOR
4Kbyte
Other Loads
MPFS,RRS,
SGS,SRRC,SPUS,SPPS,
Toner Motor
Main Motor
Mirror Motor
VFMCNT,VFM,MPFS,CPFS2,
CPFS1
Other Inputs
CPU INTERRUPT
SPPD
CPU I/O
RTH DRST
I/F PWB
Zebra2 ASIC
(296pin)
CPU
H8S/2320
(19.6608MHz)
I
E
E
E
1
2
8
4
U
S
B
1
.
1
L
S
U
Polygon
Motor
(Leopard)
EEPROM
SDRAM
Simp 16Mbyte
Reset IC
SRAM
Driver
Flash ROM
AFE(
AD9826 or AD9822)
C
D
S
A
G
C
M
P
X
A
D
16bit
s
CCD Driver
CCFL
Lamp
Inverter
HOME
POSITION
SENSOR
CCD
(TCD2704)
CRUM
CPU CLK(19.6608MHz)
Software Reset
SSCG
SFMT0/1/2/3
PMD
Driver
MM_AI0/AI1/PH_A
MM_BI0/BI1/PH_B
OPU PWB
LC7935AN
7seg LED
LED
5V
HC151
KEY
5V
LVC1284
PDIUSBP11AD
START KEY
POWER SUPPLY
/POFF,HL,PR
FW
3.3V,5VEN,5V,24V
HVU
TC,GRID,MC,
BIAS
PMCLK(2078.74(Hz))
PSW
KIN1
SELIN1,2,3
OP-CLK
OP-LATCH
OP-DATA
OP-BEO
LED
PSL,ONL
MHPS
SHIFTER
Driver
DRUM
INITIAL
SW
Sensor
SFTHP
/VIDEO
S/H
APCSTT
/SYNC
SPMT0/1/2/3
SPF
Driver
SPFCLH, SPFGSOL SPFPSOL, SPFRSOL
Sensor
Driver
Selector
L1,2
W0,1,2,3
/SPFCOVER, PAPER, SPFOPEN, /SPFOUT
SPF MOTOR
TM+,TM-
/MMRDY
/MMD
PWM
12V,5V,3.3V
0 - 24V
HC151
CLON
2nd CASSETTE
Feed SOL , Pick up SOL
CASSETTE DETECTION,
PAPER DETECTION,
PAPER PASS DETECTION,
DOOR DETECTION
/MMRDY
SELIN1,2,3
Y1
PSOL
FSOL
SCAN1-6
LCX16374
UART
POWER
FAN
[12]ELECTRICALSECTION.fm 1 ページ 2003年11月28日 金曜日 午前9時17分
AL-1633/1644 ELECTRICAL SECTION 12-2
3. Actual wiring diagram
ACTUAL WIRING DIAGRAM 1/7
B03P-VL
(WHITE)
B4B-PH-K-BL
(BLACK)
SPF GROUND WIRE
ORIGINAL TRAY HARNESS
SENSOR HARNESS
04FE-BT-VK-N
(WHITE)
B3B-PH-K-R
(RED)
Mirror HP
SENSOR
OPTICAL BASE PLATE
CCD PWB
Mirror MOTOR
COPY LAMP
THERMISTER
Side Cover SW
MAIN
MOTOR
TONER
MOTOR
DEV UN
POWER PWB
MCU-PWB
HAND PAPER PICK
UP SOLENOID
HAND PAPER EMPTY
SENSOR
TC
CASETTE EMPTY
SENSOR
PS SOL
GP1S58(C)
GP1S58(O)
2nd CASETTE
(O) Normal Open :Low
(C) Normal Close :High
GRID
MC
MCFB
BC
HVU
Bias
SPF UN
USB1.1
IEEE1284
PAPER IN
SENSOR
PICK UP SOL
FUSER
AC Cord
AC SW
HEATER LAMP
REACTOL
230V ONLY
POLYGON
MOTOR
LSU
APC-PWB
BD-PWB
COOLING FUN
I/F
FFC
FFC
FFC
FFC
FFC
FFC
Front Cover SW
SRU
CASETTE SWITCH
SENSOR
B3B-PH-K-S
(WHITE)
B3B-PH-K-R
(RED)
SUB-D 25
FE4-32-S1505
(BLACK)
B4B-PH-K-S
(WHITE)
08FE-BT-VK-N
(WHITE)
B2P-VH
(WHITE)
B3P-VH
(WHITE)
B3B-PH-K-S
(WHITE)
B20B-PHDSS-B
(WHITE)
B3B-PH-K-BK
(BLACK)
B4B-PH-K-S
(WHITE)
B2B-XH-A-S
(WHITE)
B2B-XH-A-BK
(BLACK)
B2B-XH-A-R
(RED)
B4B-PH-K-R
(RED)
B12B-PHDSS-B
(WHITE)
B26B-PHDSS-B
(WHITE)
35FE-BT-VK-N
(WHITE)
13FE-BT-VK-N
(WHITE)
B7B-PH-K-S
(RED)
B18B-PHDSS-B
(WHITE)
B4B-PH-K-S
(WHITE)
3P TERMINAL
230V ONLY
B4B-PH-K-S
(WHITE)
35FE-BT-VK-N
(WHITE)
DRUM INISAL SW
B3B-PH-K-BK
(BLACK)
B3B-PH-K-S
(WHITE)
SHIFTER
MOTOR
GP1A71A1(O)
SHIFTER HP
SENSOR
COOLING
FUN
COOLING
FUN
13FE-BT-VK-N
(WHITE)
MODEL W/O SHIFTER
MODEL WITH SHIFTER
B3B-PH-K-SX
2
(WHITE)
COOLING
FUN
COOLING
FUN
COPY OP PWB
OPERETION PANEL
IMSA-9610S-
24C
(BLACK)
Option
B6B-PH-K-S
(WHITE)
PAPER OUT
SENSOR
DUP
SENSOR
24FMN-BTRK-A
(BLACK)
3
*
[12]ELECTRICALSECTION.fm 2 ページ 2003年11月28日 金曜日 午前9時17分
LEAD-FREE SOLDER
The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder.
The alphabet following the LF mark shows the kind of lead-free solder.
(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD
When repairing a lead-free solder PWB, use lead-free solder thread.
Never use conventional lead solder thread, which may cause a breakdown or an accident.
Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use
Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use
soldering iron is recommendable.
(2) NOTE FOR SOLDERING WORK
Since the melting point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering capacity is
inferior to conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed
inferior to conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed
the heat-resistive temperature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is
confirmed.
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after
completion of soldering work.
If the soldering iron tip is discolored black during soldering work, clean and file the tip with steel wool or a fine filer.
Example:
5mm
Lead-Free
Solder composition
code (Refer to the
table at the right.)
code (Refer to the
table at the right.)
<Solder composition code of lead-free solder>
Solder composition
Sn-Ag-Cu
Sn-Ag-Bi
Sn-Ag-Bi-Cu
Sn-Ag-Bi-Cu
Sn-Zn-Bi
Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
Bi-Sn-Ag-P
Bi-Sn-Ag
Bi-Sn-Ag
a
b
z
i
n
s
p
Solder composition code
a
[13]LeadFree.fm 1 ページ 2003年11月28日 金曜日 午前9時17分
Click on the first or last page to see other AL-1644 (serv.man14) service manuals if exist.