Sharp AL-1566 (serv.man17) Service Manual ▷ View online
AL-1556/1566 TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 41
S
W
10
1
Measurement of
communication time
(image)
communication time
(image)
1: Yes
0: No
Yes
1
2
Sender’s telephone
number registration
number registration
1: Inhibit
0: Allow
Allow
0
3
Inhibited to use
0
4
0
5
0
6
ECM byte/frame
1: 64 [bytes/frame]
0: 256 [bytes/frame]
256 [bytes/frame] 0
7
Inhibited to use
0
8
0
S
W
11
1
Scanner resource
holding time out in direct
send
holding time out in direct
send
Binary input
26sec
0
2
Bit No.
Set range
Set range
1
2
3
4
5
6
7
8
1 to 255sec
0: No time out
0: No time out
0
3
0
4
1
5
1
6
0
7
1
8
0
S
W
12
1
Call time setup in
automatic transmission
(T0 timer setup)
automatic transmission
(T0 timer setup)
Binary input
45sec
0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
2
Bit No.
Set range
Set range
1
2
3
4
30 to 75sec
5sec unit
N x 5 + 30sec
5sec unit
N x 5 + 30sec
0
3
1
4
1
5
Inhibited to use
0
6
CI detection
Bit No.
6
7
4 sine wave
0
When a value outside
the set range is set,
the initial value is set.
the set range is set,
the initial value is set.
4 sine wave
0
0
3 sine wave
1
0
7
2 sine wave
0
1
0
1
1
8
Inhibited to use
1
S
W
13
1
Inhibited to use
0
2
0
3
Ringing volume
Bit No.
3
4
Medium
1
Refer to User program
“RINGER VOLUME”.
“RINGER VOLUME”.
Silent
0
0
Small
0
1
4
Medium
1
0
0
Large
1
1
5
Speaker volume in
DTMF send
DTMF send
Bit No.
5
6
Medium
1
Not used
0
0
Small
0
1
6
Medium
1
0
0
Large
1
1
7
Inhibited to use
1
8
1
S
W
14
1
Inhibited to use
0
2
1
3
0
4
1
5
0
6
0
7
0
8
0
S
W
15
1
Busy tone detection
time (Lower limit)
time (Lower limit)
1: 350ms
0: 250ms
250ms
0
2
Busy tone detection
time (Upper limit)
time (Upper limit)
1: 650ms
0: 750ms
750ms
0
3
Busy tone detection
time (Lower limit 2)
time (Lower limit 2)
1: 150ms
0: Follows SW15-1.
Follows SW15-1.
0
4
Signal send level
Binary input
–11dBm
0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
5
Bit No.
Set range
Set range
4
5
6
7
8
0 (0dBm) to 26 (–26dBm)
1
6
0
7
1
8
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
AL-1556/1566 TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 42
S
W
16
1
Modem speed
(V.33 mode or less)
(V.33 mode or less)
Bit No.
1
2
3
4
V.17 14.4kbps
1
V.27 2400bps
0
0
0
0
V.29 9600bps
0
0
0
1
2
V.27 4800bps
0
0
1
0
0
V.29 7200bps
0
0
1
1
V.33 14.4kbps
0
1
0
0
3
V.33 12.0kbps
0
1
1
0
0
V.17 9600bps
1
0
0
1
V.17 12.0kbps
1
0
1
0
4
V.17 7200bps
1
0
1
1
0
V.17 14.4kbps
Others
5
Modem speed in
reception fixed
reception fixed
Bit No.
5
6
No fixing
0
No fixing
0
0
V.29-9600BPS
0
1
6
V.27ter-4800BPS
1
0
0
V.17-14400BPS
1
1
7
Inhibited to use
0
8
0
S
W
17
1
Inhibited to use
0
2
MH fixed (Except for
SG3)
SG3)
1: Yes
0: No (depending on the other
party’s machine)
party’s machine)
No
0
3
ECM MMR mode
(Except for SG3)
(Except for SG3)
1: Yes
0: No
Yes
1
4
ECM JBIG mode
(Except for SG3)
(Except for SG3)
1: Yes
0: No
Yes
1
5
Inhibited to use
0
6
MH fixed (in SG3)
1: Yes
0: No (depending on the other
party’s machine)
party’s machine)
No
0
7
ECM MMR mode (in
SG3)
SG3)
1: Yes
0: No
Yes
1
8
ECM JBIG mode (in
SG3)
SG3)
1: Yes
0: No
Yes
1
S
W
18
1
Inhibited to use
1
2
1
3
0
4
1
5
0
6
0
7
0
8
0
S
W
19
1
Inhibited to use
0
2
1
3
0
4
0
5
0
6
Recording table
automatic print
automatic print
1: Yes
0: No
No
0
Refer to User program
“AUTO LISTING”.
“AUTO LISTING”.
7
Inhibited to use
0
8
0
S
W
20
1
Line sound monitor
range
range
Bit No.
1
2
OFF
0
When a value outside
the set range is set,
the initial value is set.
the set range is set,
the initial value is set.
OFF
0
0
Up to NSF signal send/
receive
receive
0
1
2
All
1
0
0
1
1
3
Line monitor display
1: Yes
0: No
No
0
4
Inhibited to use
0
5
Receivable memory
capacity
capacity
1: 64Kbyte
0: 128Kbyte
128Kbyte
0
6
Inhibited to use
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
AL-1556/1566 TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 43
S
W
21
1
Interval between
completion of
communication and the
next call
completion of
communication and the
next call
Binary input
6sec
0
2
Bit No.
Set range
Set range
1
2
3
4
5
6
7
8
0 to 255sec
0
3
0
4
0
5
0
6
1
7
1
8
1
S
W
22
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
23
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
24
1
Inhibited to use
0
2
0
3
Specified number
reception (ANTI JUNK
FAX)
reception (ANTI JUNK
FAX)
Bit No.
3
4
Not set.
0
Refer to Main menu
“ANTI JUNK FAX”.
When a value outside
the set range is set,
the initial value is set.
“ANTI JUNK FAX”.
When a value outside
the set range is set,
the initial value is set.
Not set.
0
0
4
Receive inhibit
0
1
0
5
Inhibited to use
0
6
Document output setup
in reception
in reception
1: Collective output after
completion of reception
completion of reception
0: Output after reception of
every page
every page
Collective output
after completion
of reception
1
7
Inhibited to use
0
8
Automatic reduction
print
1: Allow
0: Inhibit
Allow
1
Refer to User program
“AUTO RCV
REDUCE”.
“AUTO RCV
REDUCE”.
S
W
25
1
Automatic reduction
rate setup
rate setup
Binary input
10%
1
2
Bit No.
Set range
Set range
1
2
3
4
0 to 15%
0
3
1
4
0
5
Transmission end
sound tone
sound tone
Bit No.
5
6
1000Hz
0
When a value outside
the set range is set,
the initial value is set.
the set range is set,
the initial value is set.
550Hz
0
0
6
1000Hz
0
1
1
1700Hz
1
0
7
Reception end sound
tone
tone
Bit No.
7
8
1000Hz
0
When a value outside
the set range is set,
the initial value is set.
the set range is set,
the initial value is set.
550Hz
0
0
8
1000Hz
0
1
1
1700Hz
1
0
S
W
26
1
Read completion sound 1: Mute
0: 1sec
1sec
0
2
Inhibited to use
0
3
Speaker volume setup
Bit No.
3
4
Small
0
Refer to User program
“BEEPER VOLUME
(send completion
sound / receive
completion sound /
scan completion
sound / alarm sound)”
“BEEPER VOLUME
(send completion
sound / receive
completion sound /
scan completion
sound / alarm sound)”
Silent
0
0
Small
0
1
4
Medium
1
0
1
Large
1
1
5
Inhibited to use
0
6
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
AL-1556/1566 TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 44
S
W
27
1
Inhibited to use
0
2
1
3
1
4
1
5
1
6
0
7
Recording paper tray
selection
selection
Bit No.
7
8
AUTO
0
Refer to User program
“TRAY SELECTION”.
When a value outside
the set range is set,
the initial value is set.
“TRAY SELECTION”.
When a value outside
the set range is set,
the initial value is set.
AUTO
0
0
TRAY1
0
1
8
TRAY2
1
0
0
1
1
S
W
28
1
Inhibited to use
1
2
1
3
0
4
1
5
0
6
0
7
0
8
0
S
W
29
1
Number of auto switch
calls of manual
reception
calls of manual
reception
→
auto
reception
Binary input
0 time
0 Refer to User program
“# OF RINGS
MANUAL RX”.
When a value outside
the set range is set,
the initial value is set.
MANUAL RX”.
When a value outside
the set range is set,
the initial value is set.
2
Bit No.
Set range
Set range
1
2
3
4
0 to 9
Not switched when 0.
Not switched when 0.
0
3
0
4
0
5
Setup of number of
times of call rings
times of call rings
Binary input
2 times
0 Refer to User program
“# OF RINGS AUTO
RX”.
When a value outside
the set range is set,
the initial value is set.
RX”.
When a value outside
the set range is set,
the initial value is set.
6
Bit No.
Set range
Set range
5
6
7
8
0 to 9 times
0
7
1
8
0
S
W
30
1
Report output when
canceling
canceling
1: Output
0: Not output
Not output
0
2
Inhibited to use
0
3
1
4
0
5
Default data, sender
print
1: ON
0: OFF
ON
1
6
Inhibited to use
0
7
Date/sender print
position setup
position setup
1: Inside of document
0: Outside of document
Outside of
document
0
8
Inhibited to use
1
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
Click on the first or last page to see other AL-1566 (serv.man17) service manuals if exist.