DOWNLOAD Sharp AL-1217 (serv.man29) Service Manual ↓ Size: 165.61 KB | Pages: 7 in PDF or view online for FREE

Model
AL-1217 (serv.man29)
Pages
7
Size
165.61 KB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Copying Equipment / Troubleshooting the unit
File
al-1217-sm29.pdf
Date

Sharp AL-1217 (serv.man29) User Manual / Operation Manual ▷ View online

63
8
2
Gently remove the misfed paper 
from under the fusing unit as 
shown in the illustration. If the 
paper cannot be removed, proceed 
to "C: Misfeed in the transport 
area".
3
Raise the fusing unit release lever and then close the side 
cover by pressing the round projections near the side cover 
open button. The misfeed (
) indicator will go out and the 
start (
) indicator will light up.
C: Misfeed in the transport area
1
Lower the fusing unit release lever.
See "B: Misfeed in the fusing area" (p.62).
2
Open the front cover.
To open the front cover, see "INSTALLING THE TD CARTRIDGE" (p.10).
3
Rotate the feeding roller in 
the direction of the arrow 
and gently remove the 
misfed paper from the exit 
area.
The fusing unit is hot. Do not 
touch the fusing unit when 
removing misfed paper. Doing 
so may cause a burn or other 
injury.
• Do not touch the surface of the drum (green portion) of the 
drum cartridge when removing the misfed paper. Doing so 
may cause smudges on copies.
• Do not remove the misfed paper from above the fusing unit. 
Unfixed toner on the paper may stain the paper transport 
area, resulting in smudges on copies.
Feeding roller
64
4
Raise the fusing unit release lever, close the front cover and 
then close the side cover by pressing the round projections 
near the side cover open button. The misfeed (
) indicator 
will go out and the start (
) indicator will light up.
D: Misfeed in the SPF (AL-1457)
An original misfeed may occur at one of three locations: if the misfed original is seen 
from the original feeder tray, (A) in the original feeder tray; if the misfed original is not 
seen from the original feeder tray, (B) in the exit area or (C) under the feeding roller. 
Remove the misfed original following the instructions for each location. 
(A) Open the feeding roller cover and pull the original gently to the left and out 
from the original feeder tray. Close the feeding roller cover. Open and close 
the SPF to clear the SPF misfeed (
) indicator. If the misfed original 
cannot be easily removed, proceed to (C).
(B) Open the SPF and rotate the roller rotating knob to remove the misfed 
original from the exit area. If the misfed original cannot be easily removed, 
proceed to (C).
When closing the covers, be sure to close the front cover securely and 
then close the side cover. If the covers are closed in the wrong order, 
the covers may be damaged.
Feeding roller cover
Roller rotating knob
65
8
(C) If the original does not move easily into the exit area, remove it in the 
direction of the arrow while rotating the knob.
A number may appear in the display after a minus sign, indicating the 
number of the originals that must be returned to the original feeder tray. 
Open and close the SPF to clear the SPF misfeed (
) indicator, and 
then return the required number of originals. Then press the start (
key to resume copying.
65
8
(C) If the original does not move easily into the exit area, remove it in the 
direction of the arrow while rotating the knob.
A number may appear in the display after a minus sign, indicating the 
number of the originals that must be returned to the original feeder tray. 
Open and close the SPF to clear the SPF misfeed (
) indicator, and 
then return the required number of originals. Then press the start (
key to resume copying.
Page of 7