CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-V602 DISASSEMBLY AND ASSEMBLY
 6 – 4
4. REAR COVER ASSY
1 ) Remove 4 screws 
A (M6 x 22S/SW, Black), and remove the handle and the handle spacer. Remove 22 screws B (M4 x 6, Black) and 10 screws
C (M4 x 6, Black), and 5 screws D (M3 x 6, Black), and remove the rear cover assembly.
CAUTION
NOTE FOR ASSEMBLY
n
The FFC protection sheet at the top must be extended out.
SCREW TIGHTENING TORQUE
n
Screw 
A: 2.5 - 2.7N•m
n
Screw 
B,C: 0.9 - 1.1N•m
n
Screw 
D: 0.55 - 0.65N•m
FFC protect sheet
After remove
the handle 
After remove
the handle 
Handle 
spacer
B
Screw
x 22
A
Screw
x 4
D
Screw
x 5
C
Screw
x 10
CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-V602 DISASSEMBLY AND ASSEMBLY
 6 – 5
MEMO
n
When replacing the rear cover assembly, reassemble the rear cover assembly in the following procedures.
1 ) Insert the positioning section of the rear cover R into the positioning hole in the rear cover L, and fix with four screws 
A (M3 x 8B, Silver).
2 ) Attach the four corner fixing plates, and fix them with 8 screws 
B (M4 x 6, Silver).
CAUTION
NOTE FOR ASSEMBLY
n
The connected part should be properly seated. (not lifted)
SCREW TIGHTENING TORQUE
n
Screw 
A: 0.55 - 0.65N•m
n
Screw 
B: 0.7 - 0.9N•m
Locating points
Locating points
Locating points
Locating points
A
Screw
x 4
B
Screw
x 8
Corner fixing plate x 4
CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-V602 DISASSEMBLY AND ASSEMBLY
 6 – 6
5. KEY PWB
1 ) Disconnect 1 connector. Unscrew 2pcs of screws (M3 x 4 (silver)) and remove the Key PWB assy.
CAUTION
NOTE FOR ASSEMBLY
n
Since the screws used for this tool are shorter than other screws, use enough care for handling.  If other screws may be used, the LED PWB
may be damaged to breakdown.
SCREW TIGHTENING TORQUE
n
0.55 - 0.65N•m
6. AC RELAY PWB
1 ) Disconnect 5 connectors. Unscrew 7pcs of screws (M3 x 8S/SW (silver)), and remove the AC relay PWB.
CAUTION
SCREW TIGHTENING TORQUE
n
0.55 - 0.65N•m
Locating points
Locating points
Screw x 2
Screw x 7
Connector x 5
CHAPTER 6. DISASSEMBLY AND ASSEMBLY
PN-V602 DISASSEMBLY AND ASSEMBLY
 6 – 7
7. INLET HARNESS/AC SWITCH
1 ) Unscrew 2pcs of screws (M3 x 6 (silver)), and remove the AC switch angle assy.
CAUTION
NOTE FOR ASSEMBLY
n
Place it in alignment with the boss.
n
Fix the screw in the sequence of 
1 --> 2.
SCREW TIGHTENING TORQUE
n
0.55 - 0.65N•m
2 ) Unscrew the screw 
A (M4 x 6SS pan (silver)). Disconnect 4 connectors and remove the AC Switch. Unscrew 2pcs of screw B (M3 x 6 counter-
sunk (black)), and remove the inlet harness.
CAUTION
NOTE FOR ASSEMBLY
n
Make sure to attach the ground terminal with the swaged part up. Also, attach it next to the whirl-stop boss.
n
While holding the AC Switch, insert the connector.
n
When inserting the connector, check if it clicked into place.
n
After inserting the connector, ensure that it won't come off by being pulled lightly.
SCREW TIGHTENING TORQUE
n
Screw 
A: 0.9 - 1.1N•m
n
Screw 
B: 0.55 - 0.65N•m
Screw x 2
Boss
Black
White
Whirl-stop 
boss
White
Blue
Confirm that the circle 
(o) is on the left side and 
it is in the OFF state.
AC Inlet harness
AC Switch
Mark
When attaching, ensure 
that the terminals are 
oriented as indicated in the 
engraved mark.
B
Screw
x 2
A
Screw
x 1
Page of 127