Sharp LC-52XD1E (serv.man4) Service Manual ▷ View online
LC-46/52XD1E-RU
5 – 1
LC-46/52XD1E-RU
Service Manual
CHAPTER 5.
ADJUSTMENT PROCEDURE
[1] ADJUSTMENT PROCEDURE
The adjustment values are set to their optimum at the factory before shipping .
If by any chance a value should become improper or a readjustment is required due to part replacement, make an adjustment according to the fol-
lowing procedure.
lowing procedure.
1. After replacement of any PWB and/or IC for repair, note the following.
When replacing the following units, be sure to prepare the new units loaded with updated software.
MAIN-UNIT: DUNTKD915FM01 (LC-52XD1E/K/F/I/RU)
: DUNTKD915FM01 (LC-46XD1E/K/F/I/RU)
NOTE: That an IC into which ROM data is written is available for MAIN-UNIT servicing (see below).
IC1901 VHi24LC2BiNQES EDID(HDMI)
IC1902 VHi24LC2BiNRES EDID(HDMI)
IC2303 RH-iXB731WJZZS EDID(PC)
2. Software Upgrade
Main software update procedure of SHARP LCDTV
Main software update procedure of SHARP LCDTV
1. Connect your PC and LCDTV by 232C-CROSS-CABLE.
Set up starter298
2. Decompress starter_298_ver100.zip.
3. Double click on starter.exe and running.
LC-46/52XD1E-RU
5 – 2
4. Set the parameters of the starter software as below.
i)
[Options]-[Preferences] Setup window will be opened.
1) "General","Terminal","System update": no need to modify
anything.
anything.
2) "Connection": set COM port number and configuration on
your PC.
your PC.
3) "Download": set configuration as below.
5. [File]-[Save as] you can save above settings as file name as you
want.
Setting "9600"
(a) set directory path of starter tool
(b) set absolute path of target elf file
(c) set simple or packed
(d) set absolute path of "Cbus_boot_ver1.00.txt" for Cbus(boot).
¨Starter_298\Configs\Cbus_boot_ver1.00.txt
Starter_298\Configs\Cbus_flash_NoUART_
ver1.00.txt
ver1.00.txt
(e) set absolute path of "Cbus_flash_NoUART_
ver1.00.txt" for Cbus(flash).
LC-46/52XD1E-RU
5 – 3
Download
6. Connect to the LCD TV and start up "starter298" software.
7. After turn on the power of set, please push the below connect but-
ton.
NOTE: If set power was turned off and on with this condition, strange
character will be appear, so if this strange character appear,
please ignore.
please ignore.
8.
9.
in capital letters
in capital letters
Input "USEROFF" command (non-visited) and return key on your
˴˴˴˴˴˴˴˴˴˴PC. (get "OK"message)
˴˴˴˴˴˴˴˴˴˴PC. (get "OK"message)
Input "DPON" command and return key on your PC. (get "MSH>"
message)
message)
in small letters
Input "fpga 3 0x80" command and return key on your PC, and the
LCD TV is turned off automatically.
LC-46/52XD1E-RU
5 – 4
10.Change the port settings.
11.Connect to the LCD TV by activating the connection button.
12.[Programming]-[Download] Download window will be opened.
setting "115200"