Multi Display Setup Manual <Rev1.0 > September.30, 2010
16
•
The color can be adjusted by the image adjustment function of the display by operating remote
controller or the control tool offered from our company.
(Please refer to software tool SHARP Monitor Control Software.
)
•
Also, it can be adjusted with the color calibration tool from our company.
(Please refer to software tool Multi Display Calibration Tool).
It is necessary to buy our recommended colorimeter. For the adjustment of one unit, it will take
about five minutes with 6‐gradation adjustment of (our recommendation), about seven minutes
with 16‐gradation, and about 10 minutes with 32‐gradation
How to adjust the color
Color Adjustment Procedures for New Installation
Need set to a specific color
temperature and brightness
by using the colorimeter
YES
Need adjust the color with
the installation environment
NO
color temperature and
brightness are have been
adjusted at factory
End of
Adjustment
Can adjust
Adjust with the color
calibration tool
End of
Adjustment
Can adjust
Fine‐tunes with manual
adjustment for the gamma
value of the calibration tool.
End of
Adjustment
* Usually, you need not use the color calibration tool .
End of
Adjustment
Calibration (1)
Adjust with the image adjustment
function of the display
CONFIDENTIAL
CONFIDENTIAL
Multi Display Setup Manual <Rev1.0 > September.30, 2010
17
Calibration (2)
Confirm the difference of color
and brightness by eye between replaced
display and other ones
Adjust with the image adjustment function
of the display
color adjustment procedures
when display is replaced
Select a display and measure targeted
color and brightness
with the color calibration tool
No difference
color adjustment procedures for difference
of the color temperature and brightness
between displays due to change over time
Adjust the replaced display to the targeted
color and the brightness with the color
calibration tool
End of Adjustment
for One unit
End of
Adjustment
End of
Adjustment
End of Adjustment
End of
Adjustment
End of
Adjustment
Can adjust
Can adjust
Can adjust
Can adjust all
Can adjust
Select a display and measure targeted
color and brightness
with the color calibration tool
Adjust with the image adjustment function
of the display
Fine‐tunes for the gamma value
with manual adjustment of the
calibration tool.
Can adjust
Adjust to the targeted color and the
brightness with the color calibration
tool
Fine‐tunes for the gamma value
with manual adjustment of the
calibration tool.
CONFIDENTIAL
CONFIDENTIAL
Multi Display Setup Manual <Rev1.0 > September.30, 2010
18
Calibration (3)
How to implement calibration
CONFIDENTIAL
CONFIDENTIAL
Multi Display Setup Manual <Rev1.0 > September.30, 2010
19
Calibration (4)
How to implement calibration