E
29
n
ZOOM2 SPECIAL SETTING
If you connect a laptop computer with any of the following 
screen resolutions and black bands appear around the 
screen, set ZOOM2 SPECIAL SETTING of INPUT SIGNAL on
the OPTION menu to ON and then select ZOOM2 in the SIZE
setting.
This displays the area inside the black band.
Laptop computer 
resolution
Corresponding signal*
1
1280x800
1280x1024, 1280x960, 1400x1050*
2
1280x600
1280x720
1024x600
1024x768
*1: This setting is effective only when the screen resolution,
including the black band, is one of the resolutions listed 
above.
*2: Use the automatic screen adjustment.
n
SCHEDULE
You can set the time to switch the monitor on and off.
Set this function with “SCHEDULE” in the OPTION menu. (See
page 26.)
When BRIGHT is set, set BRIGHTNESS SENSOR to OFF on
the SETUP menu.
-
:
– –
– –
– –
– –
– –
– –
– –
SCHEDULE
No.
POWER DAY OF THE WEEK
TIME
INPUT
BRIGHT
– –/– –/– – – –      – – –            – –:– –:– –
PC D-SUB
(1)
-
:
– –
– –
– –
– –
– –
– –
– –
-
:
– –
– –
– –
– –
– –
– –
– –
-
:
– –
– –
– –
– –
– –
– –
– –
-
:
– –
– –
– –
– –
– –
– –
– –
-
:
– –
– –
– –
– –
– –
– –
– –
-
:
– –
– –
– –
– –
– –
– –
– –
-
:
– –
– –
– –
– –
– –
– –
– –
(5)
(2)
(3)
(4)
(6)
OK···[MENU]
1 3 6 6 x 7 6 8
V: 60 Hz    H: 47.7 kHz
1.  Press 
 or 
 to select the SCHEDULE number, and 
press 
.
2.  Set the SCHEDULE. (See the description below.)
Press 
 or 
 to select items, and press 
 or 
 to 
change the setting.
3.  Press 
MENU
.
SCHEDULE becomes effective.
(1)
●: SCHEDULE effective
-: SCHEDULE not effective
(2) POWER
ON  :  Switches the monitor on at the specified time.
OFF :  Switches the monitor off at the specified time and puts
the monitor in standby mode.
(3) DAY OF THE WEEK
Specifies the day of the week to execute the SCHEDULE.
0: ONLY ONCE
Executes the SCHEDULE once on the specified day.
Specify the day of the week to execute the SCHEDULE.
1: EVERY WEEK
Executes the SCHEDULE on the specified day of the week
every week. Specify the day of the week to execute the 
SCHEDULE. 
Periodic setting such as “Monday through Friday” is also
possible.
2: EVERY DAY
Executes the SCHEDULE every day regardless of the day
of the week.
(4) TIME
Specifies the time to execute the SCHEDULE.
Set the time on a 24-hour basis. (Factory default)
Can be entered as 12-hour time using the TIME setting in
DATE/TIME FORMAT.
(5) INPUT
Specifies the input mode at power-on. When not specifying,
the screen at the previous power-off appears.
Input modes displayed on DVI, HDMI and BNC depend on
INPUT SELECT settings.
(6) BRIGHT
Sets the brightness when changing the screen brightness at 
a specified time.
Caution
•  Do not switch off the main power after setting the
SCHEDULE.
•  Specify the correct date and time. (See page 26.) 
SCHEDULE does not function unless the date and time are
specified.
•  Check regularly that the set date and time are correct.
•  When STANDBY MODE is LOW POWER, SCHEDULE
cannot be set.
•  When a temperature abnormality occurs and the backlight
brightness is reduced, the brightness is not changed even 
if a schedule set to BRIGHT is executed.
TIPS
•  Up to 8 SCHEDULE items can be registered.
•  Setting the SCHEDULE flashes the power LED alternately
in red and orange in standby mode.
•  A SCHEDULE that has a large number has precedence
over that of a small number when schedules overlap.
Menu Items
E
30
n
ADVANCED items (AV input) (See page 23 
for additional Menu item details.)
FLESH TONE
Adjust the hue control.
3D-NR
Reduce the noise of playback images on video.
Setting a higher level reduces more noise. However, it may 
cause blurring on an image.
MPEG-NR
Reduce block noise caused by digital compression.
3D-Y/C (AV VIDEO)
Specify whether to perform 3-dimension Y/C separation.
If dot interference or cross-color is occurring in fast-motion
scenes, selecting “OFF” may improve the image quality.
C.M.S.-HUE
Adjusts color tone with 6 colors of R (red), Y (yellow), G
(green), C (cyan), B (blue), and M (magenta).
C.M.S.-SATURATION
Adjusts color vividness with 6 colors of R (red), Y (yellow), G
(green), C (cyan), B (blue), and M (magenta).
C.M.S.-VALUE
Adjusts color brightness with 6 colors of R (red), Y (yellow),
G (green), C (cyan), B (blue), and M (magenta).
TIPS
•  When FLESH TONE is set to LOW or HIGH, C.M.S.-HUE/ 
-SATURATION/-VALUE cannot be set.
Adjustments for PC screen display
n
Automatic adjustment
When you use the PC D-sub input terminal or PC RGB input
terminals to display a PC screen for the first time, or when
you change the setting of the PC, use the automatic screen
adjustment.
1.  Switch the input to PC D-SUB or to PC RGB and display 
the adjustment pattern. (See the description below.)
2.  Press 
MENU
 and use 
 or 
 to display the SCREEN 
menu.
3.  Press 
 and select “AUTO”.
4.  Press 
.
 The automatic adjustment is complete in several seconds.
5.  Press 
MENU
 twice to close the menu screen.
TIPS
•  If the screen cannot be adjusted properly with one
automatic adjustment, repeat the automatic adjustment two
or three times. Try manual adjustment if necessary.
n
Screen display for adjustment
Before making adjustments in the SCREEN menu or
PICTURE menu, display an image to brighten the entire
screen. If you are using a Windows PC, use the adjustment
pattern on the supplied CD-ROM.
Opening the adjustment pattern
The following example is performed in Windows 7.
1.  Load the supplied CD-ROM into the computer’s CD-
ROM drive.
2.  Open [CD Drive] in [Computer].
 In Windows XP, open [CD Drive] in [My Computer].
3.  Double-click [Adj_uty.exe].
 The adjustment pattern will appear.
 Adjust the screen automatically or manually.
4.  When adjustment is finished, press the [Esc] on the 
computer’s keyboard to quit the adjustment program.
5.  Eject the CD-ROM from the CD-ROM drive.
TIPS
•  If the display mode on the computer you are using is
65,000 colors, the color levels in the color pattern may
appear differently or grayscale may appear to be colored. 
(This is due to the specifications of the input signal and is
not a malfunction.)
Menu Items
31
E
You can return the settings to their factory-preset values and
restrict operations.
1.  If using the remote control unit, press 
SIZE
 until “F” 
is displayed in the upper left area of the screen, then 
while “F” is being displayed, press 
, and 
 in that order.
  If using the monitor buttons, press 
 and 
 at the 
same time until “F” is displayed in the upper left area 
of the screen, then while “F” is being displayed, press 
 and   at the same time.
OFF
UNLOCKED
ON1
ON
LED
OFF
MONITOR
FUNCTION
1/1
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
RS-232C
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
CONTROLLER INPUT
END…[MENU]
2.  Select and set the items.
ALL RESET
Resets the settings to the factory default settings.  
Press 
, select ALL RESET, and then press
MENU
.
After initialization, turn the main power switch off and
then back on.
When the PN-ZB02 (optional) is attached, press
select the resetting method, and then press 
MENU
.
ALL RESET1 ....Resets all the settings to the factory 
default settings.
ALL RESET2 ....Returns all settings to the factory default 
settings except for the following items: 
LAN SETUP, RS-232C/LAN SELECT,
ID No. SET, BAUD RATE, NETWORK,
MAIL, SERVICE & SUPPORT, and
SNMP (See pages 24, 25, and pages 49
to 52.)
ADJUSTMENT LOCK
You can disable operations on the monitor and the 
remote control unit that use buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power
on/off, FUNCTION and REMOTE CONTROL
MODE.
ON 2 ..Only the FUNCTION and REMOTE CONTROL
MODE operations are enabled.  
Disables all operations other than FUNCTION
and REMOTE CONTROL MODE (not even power
on/off).
ADJUSTMENT LOCK TARGET
Sets the target to prohibit operation of with 
ADJUSTMENT LOCK.
REMOTE CONTROL ...Prohibits remote control operation
MONITOR BUTTONS ....Prohibits monitor button operation
BOTH ........................ Prohibits remote control and 
monitor button operation
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
RS-232C
(RS-232C/LAN when the PN-ZB02 (optional) is 
attached)
Specifies whether to allow control via RS-232C or LAN
(see pages 32 and 45).
OSD DISPLAY
Shows/hides the menu, modes, and messages.
The FUNCTION and REMOTE CONTROL MODE
screens cannot be hidden.
ON 1 ............. Shows all menus, modes, and messages.
ON 2 .............  Hides messages automatically displayed 
by the display. Shows messages during 
operation.
OFF .............. Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
OFF cannot be selected when STANDBY MODE is LOW
POWER.
TEMPERATURE ALERT
Selects the notification method for an abnormal
temperature.
OFF .............. Do not notify about an abnormal
temperature.
OSD & LED .. When an abnormal temperature is
detected, the power LED flashes in red
and green alternately and the screen 
displays a message: TEMPERATURE.
LED............... When an abnormal temperature is
detected, the power LED flashes in red
and green alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the
power LED flashes in red and the screen
displays a message: STATUS [xxxx].
LED............... When a hardware error is detected, the
power LED flashes in red.
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears,
change the setting accordingly.
CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears,
change the setting accordingly.
3.  Press 
MENU
 to return to the normal screen.
TIPS
•  When both abnormal temperature and hardware error are
detected, the hardware error notification overrides.
•  If TEMPERATURE ALERT or STATUS ALERT is set to
OSD & LED, alert messages will appear even if the OSD
DISPLAY is set to ON 2 or OFF.
•  If TEMPERATURE ALERT or STATUS ALERT is set to LED
or OSD & LED, the LED lights even if the LED function is
set to OFF.
32
E
Controlling the Monitor with a PC (RS-232C)
You can control this monitor from a PC via RS-232C (COM
port) on the PC.
You can also connect multiple monitors via a daisy chain by 
using a PC. By assigning ID numbers to each monitor (see
page 34), you can make input mode selection/adjustment or
can check the status of a specific monitor.
Precautions when the PN-ZB02 (optional) is attached
•  To control the monitor via RS-232C, set RS-232C/LAN
SELECT to RS-232C.
•  You cannot use RS-232C and LAN control simultaneously.
PC connection
n
One-to-one connection with a PC
Connect with RS-232 straight cable between the PC’s COM
port (RS-232C connector) and the RS-232C input terminal on
the monitor.
RS-232 straight cable  
(commercially available) 
To COM port 
PC 
RS-232C input terminal
n
Daisy chain connection…
Advanced operation
Connect with RS-232 straight cable between the PC’s COM
port (RS-232C connector) and the RS-232C input terminal on
the first monitor.
Next, connect RS-232 straight cable to the first monitor’s
RS-232C output terminal and to the second monitor’s 
RS-232C input terminal. Connect in the same way to the third
and subsequent monitors.
Up to 25 monitors can be connected. (Depending on the
length of the cable used and the surrounding environment.)
RS-232 straight cables 
(commercially available)
First monitor
Second monitor
PC
To COM port
RS-232C 
input terminal
RS-232C 
output terminal
Communication conditions
Set the RS-232C communication settings on the PC to match
the monitor’s communication settings as follows:
Baud rate
*
Stop bit
1 bit
Data length
8 bits
Flow control
None
Parity bit
None
* Set to the same baud rate as the BAUD RATE setting of
SETUP menu. (Initial setting: 38400 bps)
* When connecting multiple monitors in a daisy chain, set all
monitors to the same BAUD RATE.
Communication procedure
n
Command format
When a command is sent from the PC to the monitor, the
monitor operates according to the received command and 
sends a response message to the PC.
C1  C2  C3  C4  P1  P2  P3  P4 
Return code 
Command field  
(4 prescribed  
alphanumerical characters) 
Parameter field 
(4 character string comprised of: 
0-9, +, -, space, ?)
Example: VOLM0030
VOLM     30
*  Be sure to input 4 characters for the parameter. Pad with
spaces (“ ”) if necessary.  
(“   ” is a return code (0D
H
, 0A
H
or 0D
H
))
Wrong  : VOLM30
Right  : VOLM     30
When inputting a negative value, specify a numerical value in
three digits.
Example: AUTR-005
Do not use spaces for MPOS, DATE, and SC01 through
SC08. Specify parameters using a specified number of
characters.
Example: MPOS010097
If a command has “R” listed for “DIRECTION” in the 
“RS-232C command table” on page 37, the current value can
be returned by using “?” as the parameter.
Example:
VOLM ? ? ? ?
From PC to monitor (How much
is current volume setting?).
30
From monitor to PC (Current
volume setting: 30).
*  If an ID number (see page 33) has been assigned 
(For example, ID number = 1).
VOLM
?
From PC to monitor.
30   001
From monitor to PC.
Page of 61
Display

Click on the first or last page to see other PN-V600 (serv.man7) service manuals if exist.