DOWNLOAD Sharp PN-A601 (serv.man5) Service Manual ↓ Size: 8.4 MB | Pages: 60 in PDF or view online for FREE

Model
PN-A601 (serv.man5)
Pages
60
Size
8.4 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Monitor
File
pn-a601-sm5.pdf
Date

Sharp PN-A601 (serv.man5) User Manual / Operation Manual ▷ View online

E
29
n
ADVANCED items (AV input) (See page 22 
for additional Menu item details.)
FLESH TONE
Adjust the hue control.
3D-NR
Reduce the noise of playback images on video.
Setting a higher level reduces more noise. However, it may 
cause blurring on an image.
MPEG-NR
Reduce block noise caused by digital compression.
3D-Y/C (AV VIDEO)
Specify whether to perform 3-dimension Y/C separation.
If dot interference or cross-color is occurring in fast-motion
scenes, selecting “OFF” may improve the image quality.
C.M.S.-HUE
Adjusts color tone with 6 colors of R (red), Y (yellow), G
(green), C (cyan), B (blue), and M (magenta).
C.M.S.-SATURATION
Adjusts color vividness with 6 colors of R (red), Y (yellow), G
(green), C (cyan), B (blue), and M (magenta).
C.M.S.-VALUE
Adjusts color brightness with 6 colors of R (red), Y (yellow),
G (green), C (cyan), B (blue), and M (magenta).
TIPS
•  When FLESH TONE is set to LOW or HIGH, C.M.S.-HUE/ 
-SATURATION/-VALUE cannot be set.
Adjustments for PC screen display
n
Automatic adjustment
When you use the PC D-sub input terminal or PC RGB input
terminals to display a PC screen for the first time, or when
you change the setting of the PC, use the automatic screen
adjustment.
1.  Switch the input to PC D-SUB or to PC RGB and display 
the adjustment pattern. (See the description below.)
2.  Press 
MENU
 and use 
 or 
 to display the SCREEN 
menu.
3.  Press 
 and select “AUTO”.
4.  Press 
.
 The automatic adjustment is complete in several seconds.
5.  Press 
MENU
 twice to close the menu screen.
TIPS
•  If the screen cannot be adjusted properly with one
automatic adjustment, repeat the automatic adjustment two
or three times. Try manual adjustment if necessary.
n
Screen display for adjustment
Before making adjustments in the SCREEN menu or
PICTURE menu, display an image to brighten the entire
screen. If you are using a Windows PC, use the adjustment
pattern on the supplied CD-ROM.
Opening the adjustment pattern
The following example is performed in Windows 7.
1.  Load the supplied CD-ROM into the computer’s CD-
ROM drive.
2.  Open [CD Drive] in [Computer].
 In Windows XP, open [CD Drive] in [My Computer].
3.  Double-click [Adj_uty.exe].
 The adjustment pattern will appear.
 Adjust the screen automatically or manually.
4.  When adjustment is finished, press the [Esc] on the 
computer’s keyboard to quit the adjustment program.
5.  Eject the CD-ROM from the CD-ROM drive.
TIPS
•  If the display mode on the computer you are using is
65,000 colors, the color levels in the color pattern may
appear differently or grayscale may appear to be colored. 
(This is due to the specifications of the input signal and is
not a malfunction.)
Menu Items
30
E
You can return the settings to their factory-preset values and
restrict operations.
1.  Press 
SIZE
 until “F” is displayed in the upper left area 
of the screen, then while “F” is being displayed, press 
, and 
 in that order.
OFF
UNLOCKED
ON1
ON
LED
OFF
MONITOR
FUNCTION
1/1
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
RS-232C
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
CONTROLLER INPUT
END…[MENU]
2.  Select and set the items.
ALL RESET
Resets the settings to the factory default settings.  
Press 
, select ALL RESET, and then press
MENU
.
After initialization, turn the main power switch off and
then back on.
When the PN-ZB01 (optional) is attached, press
select the resetting method, and then press 
MENU
.
ALL RESET1 ....Resets all the settings to the factory 
default settings.
ALL RESET2 ....Returns all settings to the factory default 
settings except for the following items: 
LAN SETUP, RS-232C/LAN SELECT,
ID No. SET, BAUD RATE, NETWORK,
MAIL, SERVICE & SUPPORT, and
SNMP (See page 24, and pages 48 to
51.)
ADJUSTMENT LOCK
You can disable operations on the monitor and the 
remote control unit that use buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power
on/off and FUNCTION.
ON 2 ..Only the FUNCTION operation is enabled.  
Disables all operations other than FUNCTION (not
even power on/off).
ADJUSTMENT LOCK TARGET
Sets the target to prohibit operation of with 
ADJUSTMENT LOCK.
REMOTE CONTROL ...Prohibits remote control operation
MONITOR BUTTONS ....Prohibits monitor switch operation
BOTH ........................ Prohibits remote control and 
monitor switch operation
RS-232C
(RS-232C/LAN when the PN-ZB01 (optional) is 
attached)
Specifies whether to allow control via RS-232C or LAN
(see pages 31 and 44).
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
OSD DISPLAY
Shows/hides the menu, modes, and messages.
The FUNCTION screen cannot be hidden.
ON 1 ............. Shows all menus, modes and messages.
ON 2 .............  Hides messages automatically displayed 
by the display. Shows messages during 
operation.
OFF .............. Hides all menus, modes, and messages.
LED
Specifies whether to light the power LED.
OFF cannot be selected when STANDBY MODE is LOW
POWER.
TEMPERATURE ALERT
Selects the notification method for an abnormal
temperature.
OFF .............. Do not notify about an abnormal
temperature.
OSD & LED .. When an abnormal temperature is
detected, the power LED flashes in red
and green alternately and the screen 
displays a message: TEMPERATURE.
LED............... When an abnormal temperature is
detected, the power LED flashes in red
and green alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the
power LED flashes in red and the screen
displays a message: STATUS [xxxx].
LED............... When a hardware error is detected, the
power LED flashes in red.
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears,
change the setting accordingly.
CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears,
change the setting accordingly.
3.  Press 
MENU
 to return to the normal screen.
TIPS
•  When both abnormal temperature and hardware error are
detected, the hardware error notification overrides.
•  If TEMPERATURE ALERT or STATUS ALERT is set to
OSD&LED, alert messages will appear even if the OSD
DISPLAY is set to ON 2 or OFF.
31
E
Controlling the Monitor with a PC (RS-232C)
You can control this monitor from a PC via RS-232C (COM
port) on the PC.
You can also connect multiple monitors via a daisy chain by 
using a PC. By assigning ID numbers to each monitor (see
page 33), you can make input mode selection/adjustment or
can check the status of a specific monitor.
Precautions when the PN-ZB01 (optional) is attached
•  To control the monitor via RS-232C, set RS-232C/LAN
SELECT to RS-232C.
•  You cannot use RS-232C and LAN control simultaneously.
PC connection
n
One-to-one connection with a PC
Connect with RS-232 straight cable between the PC’s COM
port (RS-232C connector) and the RS-232C input terminal on
the monitor.
RS-232 straight cable  
(commercially available) 
To COM port 
PC 
RS-232C input terminal
n
Daisy chain connection…
Advanced operation
Connect with RS-232 straight cable between the PC’s COM
port (RS-232C connector) and the RS-232C input terminal on
the first monitor.
Next, connect RS-232 straight cable to the first monitor’s
RS-232C output terminal and to the second monitor’s 
RS-232C input terminal. Connect in the same way to the third
and subsequent monitors.
Up to 25 monitors can be connected. (Depending on the
length of the cable used and the surrounding environment.)
RS-232 straight cables 
(commercially available)
First monitor
Second monitor
PC
To COM port
RS-232C 
input terminal
RS-232C 
output terminal
Communication conditions
Set the RS-232C communication settings on the PC to match
the monitor’s communication settings as follows:
Baud rate
*
Stop bit
1 bit
Data length
8 bits
Flow control
None
Parity bit
None
* Set to the same baud rate as the BAUD RATE setting of
SETUP menu. (Initial setting: 38400 bps)
* When connecting multiple monitors in a daisy chain, set all
monitors to the same BAUD RATE.
Communication procedure
n
Command format
When a command is sent from the PC to the monitor, the
monitor operates according to the received command and 
sends a response message to the PC.
C1  C2  C3  C4  P1  P2  P3  P4 
Return code 
Command field  
(4 prescribed  
alphanumerical characters) 
Parameter field 
(4 character string comprised of: 
0-9, +, -, space, ?)
Example: VOLM0030
VOLM     30
*  Be sure to input 4 characters for the parameter. Pad with
spaces (“ ”) if necessary.  
(“   ” is a return code (0D
H
, 0A
H
or 0D
H
))
Wrong  : VOLM30
Right  : VOLM     30
When inputting a negative value, specify a numerical value in
three digits.
Example: AUTR-005
Do not use spaces for MPOS, DATE, and SC01 through
SC08. Specify parameters using a specified number of
characters.
Example: MPOS010097
If a command has “R” listed for “DIRECTION” in the 
“RS-232C command table” on page 36, the current value can
be returned by using “?” as the parameter.
Example:
VOLM ? ? ? ?
From PC to monitor (How much
is current volume setting?).
30
From monitor to PC (Current
volume setting: 30).
*  If an ID number (see page 33) has been assigned 
(For example, ID number = 1).
VOLM
?
From PC to monitor.
30   001
From monitor to PC.
E
32
Controlling the Monitor with a PC (RS-232C)
n
Response code format
When a command has been executed correctly
Return code
(0D
H
, 0A
H
)
A response is returned after a command is executed.
*  If an ID number has been assigned
K  SPC  0 
ID number of responding monitor 
Space (20
H
Return code
(0D
H
, 0A
H
)
When a command has not been executed
Return code
(0D
H
, 0A
H
)
*  If an ID number has been assigned
SPC  0 
ID number 
Space (20
H
Return code
(0D
H
, 0A
H
)
TIPS
•  “ERR” is returned when there is no relevant command or
when the command cannot be used in the current state of 
the monitor.
•  If communication has not been established for reasons
such as a bad connection between the PC and monitor,
nothing is returned (not even ERR).
•  “ERR” may be returned when a command can’t be
received correctly due to interference from the surrounding 
environment.
  Please ensure that the system or software retries the 
command if this occurs.
•  If no monitor has been assigned the designated ID number
(e.g. if the command IDSL0002   is used, but no monitor 
with ID number: 2 is found), no response is returned.
If execution of the command is taking some time
Return code
(0D
H
, 0A
H
)
When the following commands are used, “WAIT” is returned.
In this case, a value will be returned if you wait a while. Do not
send any command during this period.
No ID number is attached to WAIT response.
•  Commands which return WAIT:
1.  When repeater control is used
2.  When an IDSL or IDLK command is used
3.  When one of the following commands is used: RSET,
INPS, ASNC, WIDE, EMAG, EPOS, PXSL, POWR,
AGIN, MWIN, MWIP, MWPP, ESTG, EMHV, EPHV,
ESHV, ENLG
When control via RS-232C is locked (to prevent use) 
using the operation lock function (see page 30)
Return code
(0D
H
, 0A
H
)
When RS-232C/LAN SELECT is set to LAN
U  N  S  E  L  E  C  T  E  D 
Return code
(0D
H
, 0A
H
)
n
Communication interval
•  After OK or ERR is returned, you must send the following
commands.
 To set a timeout for the command response, specify 10
seconds or longer. 
When connecting multiple monitors in a daisy chain, set the
timeout to at least the product of the monitor’s position from 
the computer multiplied by 10 seconds. 
Example) 3rd monitor from computer: 30 seconds or longer.
•  Provide an interval of 100 ms or more between the
command response and the transmission of the next 
command.
VOLM0020
OK
INPS0001
WAIT
OK
Interval of 100 ms or more
TIPS
•  When executing ALL RESET, set the timeout period to 30
seconds or longer. 
•  When turning the power on while the POWER ON DELAY
function is in use, set the timeout period to the POWER ON
DELAY period + 10 seconds or longer.
Page of 60
Display

Click on the first or last page to see other PN-A601 (serv.man5) service manuals if exist.