Sharp PN-70TB3 (serv.man4) Service Manual ▷ View online
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 31
3 ) Then, following window appears.
The bar progresses, if it communicates well.
If following window appears, it failed to communicate.
Then, check the connection cable and setting.
4 ) If the progress bar reaches right edge, the appearance
changes as below.
Display information appears on ITEM column on upper side of
the window.
Log data are separated into System Log and Temp Log.
Sysytem Log mainly displays user operation and machine
condition.
Temp Log displays temperature information.
(MEMO)
- This tool is not available for models which are not displayed on
the list of Model Name. Ver2.1.2.0 and subsequent version of
“InfoDisp Report” tool does not work properly with the models
older than PN-R series. In addition, the report file format is not
compatible.
The Ver2.1.2.0 and subsequent version of “InfoDisp Report” tool
does not support data storage in CSV format. In case the data
are read in Excel etc., store the data in HTML format.
16-4. SYSTEM LOGS AND TAB
Logs are displayed with list format downside. Each item’s
meanings are below.
LOG’S MEANING
LOG KIND
Header
Meaning and remark
ID
The smaller the number, the newer the log
data.
Use [ID] to line up in the order of operation.
Date
It displays date and time when operation
occurred. The icon is displayed on left edge
to stand out, if “Kind” is “Abnormal State”.
Time elapsed from
Power Supply
It displays the operation time. (The time after
turning on the power of the monitor.)
Kind
It displays the kind of log. Detail information
is described in “Log Kind”.
Input
If “Kind” is “Operation” or “Abnormal State”, it
displays the input source of main screen. If
“Kind” is “Change Signal”, it displays the
input source which signal is changed and
displays which screen (Main or Sub)’s signal
is changed in parenthesis. If “Kind” is “Power
Off Reason”, it displays none.
Information
It displays information depending on “Kind”.
Detail information is described in “Log Kind”.
Parameter 1/2
It displays parameter. Detail information is
not open.
Header
Meaning and remark
Abnormal State
Log
It displays the log about abnormal
state, for example “Temperature error”.
Abnormal kind is displayed in
“Information”.
Change Power
State Log
It displays the log of power off. The
reason of power change is displayed in
“Information”.
Change Signal
Log
It displays the log changing signal.
The timing of new signal is displayed in
“Information” as “[Width] x [Height] @
[Refresh rate]” or “No Signal”.
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 32
16-5. TEMP LOG AND TAB
The temperature information is displayed in the Temp log.
16-6. SAVE AND OPEN LOGS
It is possible to save in either original format (.IDR format) or
HTML format (.HTML format).
* To analyze the logs, save the log as the original format (.IDR
format). It is possible to read and display the files saved in
the USB flash drive.
■
Save logs
1) Click [Create Report] to save logs in file.
2) Following window appears, then specify the file name and click
[Save] button.
Header
Meaning and remark
Operation
with
IR
Remote/Key
It displays the log of operations
with IR remote or button on body.
Operation record is displayed in
“Information”.
Operation
by
RS-232C
(
Operation)
It displays the log of operation by
RS-232C command. The
command is displayed in
“Information”.
Extended
Operation
by RS-232C
(Operation)
The sent command is displayed in
“Information”.
Operation
by
Browser(Operation)
It displays the log of operation by
browser. The command the
occurred by operation
(RS-223C/LAN command) is
displayed in “Information”
Extended
Operation
by Browser
(
Operation)
Other
Operation
(
Operation)
It displays the log of operation
except above, for example, power
off by schedule timer. Operation
kind is displayed in “Information”.
Developer Info
It displays the Information for the
developer.
Header
Meaning and remark
current temperature
Temperature when receiving
the log.
the log.
direction Installed
Orientation
0:Landscape/1:Portrait
bright control thresh high
temperature error thresh
power off thresh
temperature error thresh
power off thresh
Temperature of the abnormal
operation of the monitor
operation of the monitor
minimum temperature
Minimum temperature of
monitor
The minimum temperature is
displayed when the power of
the monitor is turned on.
monitor
The minimum temperature is
displayed when the power of
the monitor is turned on.
maximum temperature
Maximum temperature
The maximum temperature is
displayed when the power of
the monitor is turned on.
The maximum temperature is
displayed when the power of
the monitor is turned on.
bright down count
The number of brightness
decrease caused by high
temperature is displayed.
decrease caused by high
temperature is displayed.
high temperature count
The number of high
temperature error is displayed.
temperature error is displayed.
power off count
The number of being turned off
caused by high temperature
is displayed
caused by high temperature
is displayed
Log
The latest five logs of Bright
down/ high temperature/ power
off are displayed.
down/ high temperature/ power
off are displayed.
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 33
3) The stored log file can be read with selecting “File” - “Open
Report File” in menu bar.
■
Save logs in HTML format
1) When “File” - “Open Report File” in menu bar is selected, the
dialog for saving is displayed.
2) Specify the file name and push [Save] button.
■
Display log saved in USB flash drive
It is possible to display the log saved in the USB flash drive.
To save the log, refer to the “14-6 SAVE AND OPEN LOGS.”.
1) When “File” - “Open Report File” in menu bar is selected, the
dialog for saving is displayed.
When “xxlog_[Model name]_[Serial number]_[Date].dat” file is
opened, the log is displayed.
■
Display of a system log attached to an abnormality
notification mail
If a log file of the display is attached to an abnormality
notification mail, it can be read by the use of this tool.
1) Save the file attached to an abnormality notification mail.
2) Select “File” - “Open Log File (Binary)” of the menu bar, and
select the saved file
3) The display log when detecting an abnormality is displayed.
16-7. DUMP NVRAM
This tool is provided with the dump acquiring function of the
NVRAM of the information display in order to check the status
when a trouble occurs as well as to acquire and display the logs.
1) Click [Get All Reports] button.
2) Following window appears. Then, specify the folder you want to
store dump files and push [OK] button.
3) Following window appears. The bar progresses if it
communicates well.
4) Following window appears after communication complete. Click
[OK] button.
5) If following window appears, it failed to communicate. Then,
check the connection cable and the setting.
16-8. OTHER FUNCTIONS
■
Sort logs
The logs are listed at first. You can sort in order of another to push
header. For example, if you push [Kind] header, the list is sorted in
order of “Kind” as below.
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3
SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 34
■
Compensate log time
This tool can compensate log time with PC’s time, because
information display is not set date and time.
<CAUTION>
・
It cannot display correct time in case that PC’s time is not correct
when it get logs or in case that user changed information
display’s date or time within the range of logs.
Select “View” - “Compensate Log Time by PC Time” in menu bar.
Then, the item in menu is checked and “Date” is compensated
by PC’s time. (It’s not checked and not compensated as default.)
■
Clear logs
Select “File” - “Clear Logs” in menu bar. Then, confirming dialog
as below appears.
Logs stored in information display will be removed if you push
[OK] button.
It erases logs in information display and list, so logs should be
stored to file if you need to find out a problem.
For the logs of “Power OFF cause,” “Signal change,” and
“Operation,” when the number of items exceeds the maximum
number, the oldest one is deleted and the newest one is saved.
When, however, even one log of “Abnormal state” is saved, the
logs of “Power OFF cause,” “Signal change,” and “Operation” are
not revised in order to maintain the analysis information at
occurrence of the abnormality. In such a case, clear the logs with
this function.
Click on the first or last page to see other PN-70TB3 (serv.man4) service manuals if exist.