2. Check the continuity of the fuse F1 and protector F21 on the power unit as follows.
i)
Disconnect the power supply cord, and then remove outer case and rear cover.
ii) Open the door and block it open.
iii) Discharge two high voltage capacitors.
iv) Remove the power unit from the oven, referring to “POWER UNIT REMOVAL”.
v) Check the continuity of the fuse F1 and the protector F21. 
vi) If they are open, the power unit is defective
[18] R: RELAY UNIT TEST
1. CARRY OUT 3D CHECKS.
2. Remove the relay unit from the oven, referring to “RELAY UNIT REMOVAL”.
3. Check the continuity of the FUSE1 on the relay unit.
1) If it is open, the relay unit is defective.
4. Check the open and /or short of the transformer primary coil on the relay unit.
1) If it is open and /or short, it is defective.
5. Check the state of the relays contacts RY-1, RY-2 and RY-3 using an ohmmeter.
1) The relay contacts should be open. If not so, the relay unit is defective.
[19] S: ANTENNA SENSOR TEST
There is no test procedure for the antenna sensor.
When the error history display shows EE15, EE25 or EE35, if the antenna motors, control unit and wiring are normal, the antenna sensor may be
defective.
[20] T: MICROWAVE SENSOR TEST
There is no test procedure for the microwave sensor.
When the error history display shows EE18, EE28 or EE38, if the magnetrons, control unit and wiring are normal, the microwave sensor may be
defective.
R1900M
7 – 1
R1900M
Service Manual
 
CHAPTER 7. 
TOUCH CONTROL PANEL ASSEMBLY
[1] SPECIAL FUNCTION FOR SERVICING
This oven has the special functions for servicing as shown in the table 1 ~ 4.
By using the special function, service person can check the using time or the using number of times for the electrical parts. Also service person can
check the AC supply voltage and /or set the standard voltage.
When “SF-2” is selected, the display will show the total cooking number of times.
Table 1. Total cooking number of times
The service person can check and /or carry out the contents as shown in the table 2.
Table 2. Special function
NOTE: The function marked “yes” can be used only after the oven is plugged in again.
1. Check, clear and set of using time or number of times
When the display shows “CC” and the number as shown in the table 3,
1) Before replacing the parts, check the using time or number of times about the parts.
2) If the using time or number of times go over the limit level, replace the defective parts.
3) After replacing the parts, clear the using time or number of times about the parts, referring to the table 4.
Table 3. CC error
The using time or using number of times can be checked or set by using the number pads after “SF-2” is set.
Table 4. Using time or number of times about each part
Set
Contents (decimal)
Max.
Data clear
New data set
SF-2
Total cooking number of times
9999(x100) times
contents
key
Display
After plug in
Check, clear and set of using time or number of times
2
SF-2
Error history
4
SF-4
Check of AC supply voltage
5
SF-5
Exhaust thermistor check
6
SF-6
Yes
Set standard voltage for production.
7
SF-7
Yes
Model name
Making date of software
CUSTOM HELP
cd XX (Model)
XX XX (Date)
XX XX (Time)
Display
Content
Limit level
Action
“CC”, “1.” repeatedly
Magnetron 1 (top)
1250 hour
Display only
“CC”, “2.” repeatedly
Magnetron 2 (bottom)
1250 hour
Display only
“CC”, “3.” repeatedly
Exhaust fan
3000 hour
Display only
“CC”, “4.” repeatedly
Need to change relay unit
MG Relay 200000 times Display only
“CC”, “1.2.4.” repeatedly
Some maintenance occurs same time
Ex. Magnetron 1&2 and relay unit
Display only
Contents (decimal)
10 key
Max.
Data clear
New data set
Using time of MG 1 (top)
1
9999 hours
Using time of MG 2 (bottom)
2
9999 hours
Using number of times of MG 1 (top) relay
3
999 (x 1000) times
Using number of times of MG 2 (bottom) relay
4
999 (x 1000) times
Total cooking time (hour. min.)
5
99 hours 59min.
Total cooking time (hundred hour)
6
9999 hundred hours
Using time of exhaust fan
7
9999 hours
R1900M
7 – 2
For example: Procedure to check the total cooking number of times (example, 957700 times) and using time (example, 1260 hours) of MG 1
and set 0 hours after MG1 is replaced.
: no sound     : 0.1 second sound       : 2.0 second sound     : (0.06 sec. ON, 0.06 sec. OFF) x 2 beeps 
 
✩: [(0.04 sec. ON, 0.04 sec. OFF) x 3] x 4 beeps    : (0.1 sec. ON, 0.1 sec. OFF) x 10 beeps
For example: Procedure to check the total cooking number of times (example, 957700 times) and clear it and check using time (example,
1260 hours) of MG 1 and set the using time (example, 1000 hours) of MG1.
2. Error history (SF-4)
You can check the most recent 10 error histories.
For example: Procedure to check the error histories that have been memorized in memory 1, memory 2 and memory 9.
#1 If there is no error “0" will be displayed. 
#2 If you touch POWER LEVEL, all history are cleared. 
Operation
Display
Indicator
Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
2
(after 1 sec.)
1
MANUAL/ REPEAT
START
STOP/CLEAR
CHECK
CHECK
.
.
.
.
SF-
SF2
9577
(total counter for serviced [x 100])
1260
0
SF-2
0
Operation
Display
Indicator
Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
2
(after 1 sec.)
MANUAL/ REPEAT
START
1
MANUAL/ REPEAT
1,0,0,0
START
STOP/CLEAR
CHECK
CHECK
.
.
.
.
SF-
SF2
9577
(total counter for serviced [x 100])
0
SF-2
1260
0
1000
SF-2
0
x4
Operation
Display
Indicator
Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
4
1 (latest error No.)
2 (1 time previous error)
9 (8 times previous error)
POWER LEVEL
.
.
.
.
SF-
SF-4
EE 1
EE 6
EE24
0
#2
#1
R1900M
7 – 3
3. Check of AC supply voltage (SF-5)
You can check the current voltage of AC supply.
For example: Procedure to check current voltage (In case of over
230V)
For example: Procedure to check current voltage (In case of
under 230V)
For example: Procedure to check current voltage (In case of over
264V(240 +10%)
For example: Procedure to check current voltage (In case of
under 202V(230V--12%)
4. Exhaust thermistor check (SF-6)
You can check if the exhaust thermistor works correctly or not by using this function.
For example: In case the exhaust thermistor works correctly (275ml water load is necessary.), the display will show “OH” as follows.
Operation
Display Indicator Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
5
STOP/CLEAR
.
.
.
.
SF-
HIGH
0
(over230V)
Operation
Display Indicator Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
5
STOP/CLEAR
.
.
.
.
SF-
LO
0
(under 230V)
Operation
Display Indicator Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
5
STOP/CLEAR
.
.
.
.
SF-
EE4
0
Operation
Display Indicator Sound
(within 20 sec.)
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
5
STOP/CLEAR
.
.
.
.
SF-
EE5
0
Operation
Display
Indicator
Sound
(within 20 sec.)
(within 20 sec.)
plug in
POWER LEVEL
SET MEMORY
START
STOP/CLEAR
6
START
(after 5 min.)
STOP/CLEAR
STOP/CLEAR
ON
or
.
.
.
.
SF-
SF-6
5.00
(count down)
OH
SF-1
0
or
Page of 50