DOWNLOAD Sharp UP-5300 (serv.man2) Service Manual ↓ Size: 17.14 MB | Pages: 74 in PDF or view online for FREE

Model
UP-5300 (serv.man2)
Pages
74
Size
17.14 MB
Type
PDF
Document
Service Manual
Brand
Device
EPOS / UP5300 Internal Printer (UPT80BP) Service Manual
File
up-5300-sm2.pdf
Date

Sharp UP-5300 (serv.man2) Service Manual ▷ View online

13. Connect the Printer cables to the CONTROL
PWB.
1) SWITCH UNIT CABLE 
I
: Connect to the CN7.
2) HEAD CABLE 
O
: Connect to the CN5.
Attach the FERRITE CORE 
V
 and CABLE
CLAMP 
4
.
Fix the CABLE CLAMP 
4
 with a
SCREW 
X
.
3) AUTO CUTTER RELAY PWB CABLE 
L
: Connect to the CN4.
4) MOTOR CABLE 
Q
: Connect to the CN2.
5) SENSOR CABLE 
R
: Connect to the CN6.
6) I/F CABLE 
8
: Attach the Ferrite core 
[
.
Fig. 8
14. Wiring for each cables as shown below
Fig. 9
26
22
13
21
16
19
4
28
: XEBSD30P08000
28
8 – 3
15. Install the BOTTOM PLATE 
2
.
Fig. 10
16. Install the PRINTER COVER 
Y
.
Fig. 11
1. LIST FOR SCREWs
No.
PARTS CODE
M [mm]
L [mm]
K
XEBSD30P08000
3
8
Z
X
S
-
a
XEBSD26P06000
2.6
6
S
-
b
S
-
c
XEBSD26P08000
2.6
8
S
-
d
7
XHBSD30P06000
3
8
U
2. INSTALLATION OF PAPER NEAR END SENSOR 
[PARTS LIST]
No.
PARTS NAME
PARTS CODE
NOTE
1
PAPER NEAR
END SENSOR
DUNTK3819BHZZ
SENSOR UNIT,
FIXING SCREW
2
NEAR END
SENSOR
CONNECTOR
QCNCM6865RC0B
2 pin connector
1. Remove the BOTTOM PLATE .
2. Remove the PS+CONTROL PWB .
3. Solder the CONNECTOR 
1
 to the PS+CONTROL PWB (No.
CN1)
4. Install the NEAR END SENSOR UNIT 
2
 to the CABINET , and
fix it with the fixing SCREW 
3
.
Fig. 12
2
1
29
L
M
L
M
1
3
2
8 – 4
CHAPTER 9. DIAGNOSTICS
FUNCTION 
1. General
This chapter describes the diagnostic program installed to the UP-
T80BP and its operations. 
The purpose of this diagnostic program is to check the machine
operations in servicing and evaluate the product by continuous opera-
tions.
The diagnostic program is started by the command from the host.
Application software for test which is performed in the host PC by the
command is available. 
This chapter, therefore, describes both the stand-alone operations of
the UP-T80BP and test application of the host, which are identified as
the stand-alone test (UP-T80BP stand-alone) and the connection test
(host).
The intended host machine is PC-AT or its compatible machines with
DOS 6.2. In this chapter. 
2. Test program start
2-1. Stand-alone test
(1)
Turn off all DIP SW2. (DIP SW1 is ignored.)
(2)
Set the MASTER RESET switch (MRS SW) to the MRS side.  
(3)
With the PF key pressed, supply the AC power. (The machine
enters the test mode.)
(4)
Turn on the DIP switch (DS1/2) corresponding to the test to be
executed.
(For setting the DIP switch, refer to "3. Program Code List" on
page 10-2.)
(5)
Turn on the on-line key to start the test program. 
(6)
After completion of the test, turn off the power switch and set the
DIP switch for shipment.
Shipment setting: DIP SW1/2 = All OFF (No need to change for
the connection test.)
MRS SW = 1 side (Continue) (No need to
change in connection test.)
(7)
After completion of the test, turn off the power switch and return
the DIP switch to the original state.
(8)
Execute the master reset and cancel the test mode.
Note:
1
When the power is turned on, the printer cable connection and
the sensor cable connection are tested.
When there is no connection, the operation is terminated.  
2
As the conditions for entering the test mode, (DIP SW1 is ig-
nored) and DIP SW2 to ALL OFF.
If the power is turned on with DIP SW2 tab set to ON, "IPL ERR"
occurs. 
To cancel the test mode, perform the master reset.
3
To test the all functions of the control PWB, perform the auto
test after completion of the DIP switch test. 
2-2. Connection test (Procedure with UP-T80BP
test ROM used in the host)
Host: POS machine with TTL level RS232C communication function
(without UP-3300 or UP-5300)
For details of entering the diag mode, follow the DIAG specifications
of each host.
The UP-T80BP connection test program must be installed to
the host before test.
The DIP SW 1/2 of UP-T80BP must be set to OFF. (*Factory
setting)
(1)
Connect the UP-T80BP RS232 connector cable to the TTL level
RS232 connector of the host.  Then connect the AC cable to the
host.
(2)
With the PF key of UP-T80P pressed, 
turn on the power switch of the host.
: Entering the initial menu.
(When the MRS SW is on 1 side,
perform this procedure after 
executing MRS.)
: DIAG mode 
(3)
Select the setup item on the host’s
setup menu and pres the enter key.
: Selection of setup item 
Parity select:
Even/Odd/  None 
Data rate (bps):2400/4800/9600/19200/  38400 
(4)
After completion of host setup,
the machine enters the menu display.
: Entering the menu.
(5)
Select an item on the host’s menu.  
: Execution of each test 
(6)
To cancel the test item, use the host.  
Note: 
1
The following setup items must be the identical between the UP-
T80BP DIP switch setup and the host setup.
bit format/parity select/data rate
For details, refer to "DIP SWITCH TABLE."
SW1
3
1
2
CPU
CONTROL PWB
2
1
MRS
MRS SW
TTL LEVEL RS232
1
8
1
8
OFF
P-ROM
DS1
DS2
ON
OFF
ON-LINE ERROR
PANEL PWB
ON-LINE
PF
RS232 CABLE
UP-T80BP
HOST
AC
9 – 1
2
The RS232 cable specifications between UP-T80BP and the
host are as follows;
3. Program code list
(1) UP-T80BP stand-alone test
*
After turning on the DIP switch, press the "ON-LINE" key to start
the test.
(2) Connection test with the host
*
Select the test item on the menu screen of the host.
Test NO.
Test item
(Menu screen)
Stand-alone
test
Connection
test with host
001
KEY/LAMP
Diagnostics
(DIP SW ON/OFF
Diagnostics)
Included in
AUTO.
SW1-1
MENU 01
None
002
PRINTER
Diagnostics
SW1-2
MENU 02
003
PRINTER CG
Diagnostics
SW1-3
MENU 03
004
SW1-4
MENU 04
005
SW1-5
MENU 05
006
(RS232 LOOP
Diagnostics)
SW1-6
None
007
FLASH ROM & CG
ROM SUM
Diagnostics
SW1-7
MENU 06
008
RAM Diagnostics
SW1-8
MENU 07
009
AUTO Diagnostics
SW1&SW2
ALL ON
MENU 08
010
AGING Diagnostics
SW1 ALL ON
SW2 ALL OFF
MENU 09
011
PAPER END/NEAR
END/HEAD UP
Diagnostics
None
MENU 10
012
A/D CONVERSION
Diagnostics
None
MENU 11
013
DIP SW & HEAD
Diagnostics
Included in
AUTO.
MENU 12
014
ONE CYCLE
PRINTING
Diagnostics
SW2-1
MENU13
015
CYCLIC PRINTING
Diagnostics
SW-2
MENU 14
SW2-3
MENU 15
SW2-4
MENU 16
SW2-5
MENU 16
SW2-6
MENU 16
SW2-7
MENU 16
SW2-8
MENU 16
Test item
cancel
Diagnostics END
Auto end
MENU 17
Note: (  ) in the connection test is not displayed on the menu screen.
Only the aging test is terminated when the power is turned off. 
4. Test items
4-1A. Key/Lamp test
(1) Operation
*
Stand-alone test: None (Included in the auto test)
*
Connection test: Test item selection 
 ENTER key ON.
(2) Content
1) Press PF 
 ON-LINE keys in this sequence.
2) ON-LINE 
 ERR lamp light up in this sequence for 0.5sec each
then go off.
(3) Check contents
Check the visually. 
(4)  Cancel
After completion of the test, the end print is printed and the operation
is terminated.
TEST001:END (End print)
4-1B. DIP switch ON/OFF test
(1) Operation 
*
Stand-alone test: SW1-1 
 ON-LINE key ON
*
Connection test: None 
(2) Content
1) Set DIP SW1/2 to ALL OFF.
2) Turn on DIP switches one by one in the sequence of SW1-1 
SW1-8  SW2-1 
 SW2-8. 
3) If O.K., after completion of SW2-8, the print is made.           
                                         TEST=001:OK
4) In case of ERR, the test is interrupted and print is made.       
                                         TEST=001:ERR
(3) Check content
Check the print. 
(4) Cancel
After completion of the above print, the test is terminated. 
4-2. Printer test
(1) Operation 
*
Stand-alone test: SW1-2 
 ON-LINE key ON
*
Connection test: Selection of test item 
 ENTER key ON
(2) Content
A receipt and a journal are printed in 5 lines of special characters and
the receipt is issued.
The character side is 12 
×
 24, and the number of characters is 48
characters for each of receipt and journal.
                                   RECEIPT
SD   :     2
RD   :     3
DR   :     4
ER   :     6
CS   :     7
RS   :     8
SG   :     5
2   :     RD
3   :     SD
4   :     ER
6   :     DR
7   :     RS
8   :     CS
5   :     SG
UP-T80BP
HOST
SIGNAL PIN
PIN SIGNAL
FULL CUT
9 – 2
Page of 74