DOWNLOAD Sharp UP-3500 (serv.man33) Service Manual ↓ Size: 4.79 MB | Pages: 127 in PDF or view online for FREE

Model
UP-3500 (serv.man33)
Pages
127
Size
4.79 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
EPOS / UP3500 V2 Inst Manual (ROM 1.10) please refer to version history release notes 17 12 08
File
up-3500-sm33.pdf
Date

Sharp UP-3500 (serv.man33) User Manual / Operation Manual ▷ View online

51
■ PLU menu keys (categories)
Items can be categorized into PLU menu keys for ease of registration.
A PLU menu key can contain both PLU items and other PLU menu keys. This can make a PLU menu tree
of choices.
When the item (direct PLU) key is programmed within the PLU menu key, touch the corresponding PLU
menu key (main PLU menu key), then select the item (or sub-PLU menu key).
(Example: 
 [DRINK] 
 [WINE] 
 [WHITE] 
 [NICE WINE] )
(Example: 
 [DRINK] 
 [WINE] 
 [ROSE] 
 [GREAT WINE] )
(Example: 
 [DRINK] 
 [BEER] 
 [LIGHT] 
 [NICE BEER] )
Main PLU
menu key
Sub-PLU
menu key
Item
52
■ PLU level shift (for direct PLUs)
This shift can double or triple the number of direct PLUs on your POS terminal without adding additional
direct PLU keys. You can use direct PLUs in ten levels by utilizing the PLU level shift number key
[LEVEL#] or the PLU level shift keys [LEVEL1] through [LEVEL10].
Level key shifts the PLU level from the other nine to the required level. (The normal level is the level 1.)
You must program your terminal in the PGM mode to select one of the two PLU level shift modes —
automatic return mode* and lock shift mode** — and decide whether to allow PLU level shift in both the
REG and MGR modes or in the MGR mode alone.
* The automatic return mode automatically shifts the PLU level back to level 1 after touching a direct PLU
key or finalizing each transaction.
** The lock shift mode holds the current PLU level until a PLU level shift key is touched.
••••• Automatic return mode (for PLU levels)
If your terminal has been programmed for PLU level in the automatic return mode, touch a desired PLU
level shift key before a numeric entry.
(Returning every item entry)
 [LEVEL2] through [LEVEL10] 
 { Q’ty 
 [X/QTY] } 
 [Direct PLU key] 
 Return to level 1
 Level no. (2 - 10) 
 [LEVEL#] 
 { Q’ty 
 [X/QTY] } 
 [Direct PLU key] 
 Return to level 1
(Returning every transaction)
 [LEVEL1] through [LEVEL10] 
 { Q’ty 
 [X/QTY] } 
 [Direct PLU key] 
 … 
 (Finalization) 
Return to level 1
 Level no. (1 - 10) 
 [LEVEL#] 
 { Q’ty 
 [X/QTY] } 
 [Direct PLU key] 
 … 
 (Finalization) 
Return to level 1
When you use the FF method, you need not touch the [X/QTY] key for multiplication entries.
••••• Lock shift mode (for PLU levels)
If your terminal has been programmed for PLU level in the lock shift mode, touch a desired PLU level shift
key before a numeric entry.
 [LEVEL1] through [LEVEL10] 
 { Q’ty 
 [X/QTY] } 
 [Direct PLU key] 
 Stay in the current level
 Level no. (1 - 10) 
 [LEVEL#] 
 { Q’ty 
 [X/QTY] } 
 [Direct PLU key] 
 Stay in the current level
When you use the FF method, you need not touch the [X/QTY] key for multiplication entries.
53
     When the POS terminal has been programmed for the automatic return mode (by one item):
Key Operation
Display
           Level 1 key 
[PLU 00001 ]
           Level 2 key 
[LEVEL2] [PLU 00051 ]
           Level 1 key 
[PLU 00002 ]
[CASH_TOTAL]
     When the POS terminal has been programmed for the lock shift mode:
Key Operation
Display
           Level 1 key 
[LEVEL1] [PLU 00001 ]
           Level 2 key 
[LEVEL2] [PLU 00051 ]
           Level 2 key 
[PLU 00052 ]
[CASH_TOTAL]
54
■ Price level shift
Eight different price levels can be programmed for each PLU/EAN.
The price levels can be changed for PLU/EAN registrations.
You can shift the PLU/EAN price level (level 1 through 8) by utilizing the price level shift number key
[PRICE_SHIFT#] or the price shift keys [PRICE_SHIFT1] through [PRICE_SHIFT8].
You must program a price level shift mode (i.e. automatic return mode* or lock shift mode**) and the
operating modes to be used for the price level shift (i.e. both REG and MGR modes or MGR mode alone).
* The automatic return mode automatically shifts the PLU/EAN price level back to level 1 after a PLU/EAN
shift entry. You can select whether the price level should return each time you enter one item or each
time you finalize one transaction.
** The lock shift mode holds the current PLU/EAN price level until touching a price level shift key.
••••• Automatic return mode (for price shifts)
If your terminal has been programmed for PLU/EAN price level in the automatic return mode, touch a
desired Price level shift key before a numeric entry.
(Each item)
 [PRICE_SHIFT1] through [PRICE_SHIFT8] 
 { PLU/EAN entry } 
 Return to level 1
 Price level no. (1 - 10) 
 [PRICE_SHIFT#] 
 { PLU/EAN entry } 
 Return to level 1
(Each transaction)
 [PRICE_SHIFT1] through [PRICE_SHIFT8] 
 { PLU/EAN entry } 
 … 
 (Finalization) 
 Return to
level 1
 Price level no. (1 - 10) 
 [PRICE_SHIFT#] 
 { PLU/EAN entry } 
 … 
 (Finalization) 
 Return to
level 1
••••• Lock shift mode (for PLU levels)
If your terminal has been programmed for PLU/EAN price level in the lock shift mode, touch a desired price
level shift key before a numeric entry.
 [PRICE_SHIFT1] through [PRICE_SHIFT8] 
 { PLU/EAN entry } 
 Stay in the current level
 Price level no. (1 - 10) 
 [PRICE_SHIFT#] 
 { PLU/EAN entry } 
 Stay in the current level
Page of 127
Display

Click on the first or last page to see other UP-3500 (serv.man33) service manuals if exist.