Sharp ER-A771 (serv.man7) User Manual / Operation Manual ▷ View online
27
Starting Cash Memory Entry
If you enter an amount of change (starting cash) in the drawer before starting entry operations, you can
discriminate that amount from the sales amount when reports are generated.
Your POS terminal can be programmed to enforce the entry of starting cash into memory. For details,
contact your authorized SHARP dealer.
discriminate that amount from the sales amount when reports are generated.
Your POS terminal can be programmed to enforce the entry of starting cash into memory. For details,
contact your authorized SHARP dealer.
Select the OP X/Z mode and perform the following operation:
XXXXXXXX
Amount
(max. 8 digits)
e
Select SCM(+) or SCM(–)
Procedure
28
Entries
Item Entries
Single item entries
Department entries
Enter a unit price and press a department key.
If you use a programmed unit price, press a department key only.
Enter a unit price and press a department key.
If you use a programmed unit price, press a department key only.
*Less than a programmed upper limit amount
When those departments for which the unit price has been programmed as zero (0) are entered with the
preset unit price, only the sales quantity is added.
preset unit price, only the sales quantity is added.
NOTE
Example
When using a programmed unit price
*Open price
(max. 8 digits)
(max. 8 digits)
DEPT
Procedure
Key operation
1200
6
7
c
7
c
Display
REG MODE
6
Direct PLU entries (PLU entries and subdepartment entries)
Follow this procedure:
Follow this procedure:
*Less than the programmed upper limit amount
PLU menu-based entries (PLU entries and subdepartment entries)
Follow this procedure:
Follow this procedure:
*Less than the programmed upper limit amount
Example
Item selection from
the menu window
the menu window
thru
When using a programmed unit price
*Open price
(for subdept. entries)
e
PLU
MENU50
PLU
MENU01
Procedure
Example
Direct PLU
When using a programmed unit price
*Open price
(for subdept. entries)
e
Procedure
Key operation
)
c
c
Display
Key operation
c
Display
PLU
MENU01
Select PLU code 15
from the menu window.
from the menu window.
29
30
P
LU code entries (PLU entries and subdepartment entries)
Follow this procedure:
* Less than a programmed upper limit amount
When those PLUs for which the unit price has been programmed as zero (0) are entered, only the sales
quantity is added.
quantity is added.
Subdepartment (open PLU) entries
Follow this procedure:
Follow this procedure:
* Less than a programmed upper limit amount
Example
* Open price
`
PLU code
P
Procedure
NOTE
Example
PLU code
When using a programmed unit price
*Open price
(for subdept. entries)
e
P
Procedure
Key operation
2
P
60
P
750
e
c
c
Display
Key operation
1000
`
60
P
c
c
Display
Click on the first or last page to see other ER-A771 (serv.man7) service manuals if exist.