DOWNLOAD Sharp XE-A303 (serv.man4) Service Manual ↓ Size: 2.15 MB | Pages: 32 in PDF or view online for FREE

Model
XE-A303 (serv.man4)
Pages
32
Size
2.15 MB
Type
PDF
Document
Service Manual
Brand
Device
ECR / XE-A303 Service Manual
File
xe-a303-sm4.pdf
Date

Sharp XE-A303 (serv.man4) Service Manual ▷ View online

XE-A303 (V)
SPECIFICATIONS
– 2 –
The mode switch has these settings:
5. DISPLAY
5-1. OPERATOR DISPLAY
Layout:
5-2. CUSTOMER DISPLAY
Layout:
Operator display
•  Clerk code or Mode name
The mode you are in is displayed. When a clerk is assigned, the clerk
code is displayed in the REG or OP X/Z mode. For example, “
*
01
*
is displayed when clerk 01 is assigned.
• Repeat
The number of repeats is displayed, starting at “2” and incremental
with each repeat. When you have registered ten times, the display will
show “0” (2 
3
 3......9 
3
 0 
3
 1 
3
 2...)
• Sentinel mark
When amount in the drawer reaches the amount you prepro-
grammed, the sentinel mark “X” is displayed to advise you to remove
the money and put it in a safe place.
•  Power save mark
When the cash register goes into the power save mode, the power
save mark (decimal point) lights up.
•  Function message display area
Item labels of departments and PLU/subdepartments and function
texts you use, such as %1, (-) and CASH are displayed.
When an amount is to be entered or entered, “AMOUNT” is dis-
played: When an amount is to be entered, ------- is displayed at the
numeric entry area with “AMOUNT”. When a preset price has been
set, the price is displayed at the numeric entry area with “AMOUNT”.
•  Numeric entry display area
Numbers entered using numeric keys are displayed here.
Date and time display
Date and time appear on the display in the OP X/Z, REG, or MGR
mode. In the REG or MGR mode, press the [#/TM/SBTL] key to dis-
play the date and time.
Error message
When an error occurs, the corresponding error message is displayed
in the function message display area.
Customer display (Pop-up type)
q
:
This mode locks all register operations. (AC power turns off.)
No change occurs to register data.
OP X/Z: To take individual clerk X or Z reports, and to take flash
reports.
It can be used to toggle receipt state “ON” and “OFF” by
pressing he [RCP/PO] key.
REG:
For entering sales.
PGM:
To program various items.
p
:
Enters into the void mode. This mode allows correction after
finalizing a transaction.
MGR:
For manager’s entries. The manager can use this mode for an
override entry.
X1/Z1:
To take the X/Z report for various daily totals.
X2/Z2:
To take the X/Z report for periodic (weekly or monthly) consol-
idation.
Display device:
LCD
Number of line:
2 line
Number of positions: 16 positions/line
Color of display:
Yellow Green, Orange
Character form:
5 x 7 dots
Character size:
9.7 (H) x 4.8 (W) mm
Display device:
LED
Number of line:
1 line
Number of positions: 7 positions
Color of display:
Yellow Green
Style:
Pop up type
Character form:
7 segment + Dp
Character size:
14.2mm (H) x 7.9mm (W)
Function message display area
Clerk code or mode name
Numeric entry display area
Receipt OFF indicator
Repeat / Sentinel mark / Power save mark
Power save mark
(Lighting the mark only under the power save mode)
XE-A303 (V)
SPECIFICATIONS
– 3 –
6. PRINTER
6-1. PRINTER
6-2. PAPER
• Paper roll dimension: 57.5
m
0.5mm
in width
Max. 81mm
in diameter (80
m
1mm)
• Paper quality:
Journal/Receipt
High-quality paper
(paper thickness: 0.06 to 0.08mm)
Nihon seisi thermal paper:  TF50KS-E
Oji thermal paper: 
PD150R, PD160R
6-3. LOGO STAMP
• No
6-4. CUTTER
•  Method : Manual
6-5. PRINTING AREA
Receipt & Journal
7. DRAWER
[OUTLINE]
•  Standard equipment: Yes
•  Max. number of additional drawers: 1
•  The drawer consists of:
1) Drawer box (outer case) and drawer
2) Money case 
3) Coin case
4) Lock (attached to the drawer)
[SPECIFICATION]
7-1. DRAWER BOX AND DRAWER
7-2. MONEY CASE
7-3. LOCK (LOCK KEY : LKGIM7331BHZZ)
• Part number:
M-T203+M-T205
•  NO. of station:
2 (Receipt and journal)
• Validation:
No
• Printing system:
Line thermal
•  No. of dot:
Receipt
360 dots
Journal
360 dots
• Dot pitch:
Horizontal
0.125mm
Vertical
0.125mm
•  Font:
10 dots (W) x 24 dots (H)
•  Printing capacity:
Receipt
max. 30 characters
Journal
max. 30 characters
•  Character size:
1.25mm (W) x 3.0mm (H) at 10 x 24 dots
•  Print pitch:
Column distance 1.5mm
Row distance
3.75mm
•  Print speed:
Approximate 65mm/s (17.3 lines/sec)
•  Paper feed speed:
(Manual feed)
Approximate 40mm/s
•  Reliability:
Mechanism MCBF 6 million lines
Head life 12.5 million characters
(at 4 dots/1 character/1 element)
•  Paper end sensor: Set up (Receipt and journal)
• Cutter:
Manual
• Near end sensor:
No
0.125
Receipt
Journal (units;mm)
45
(360dots)
(360dots)
45
4
4.5
57.5 
m
0.5
57.5 
m
0.5
Model name of the drawer box
SJ420
Size
355 (W) x 424 (D) x 125 (H) mm
color
Gray (PB-N8.0)
Material
Metal
Bell
Release lever
Standard equipment: situated at the
bottom
Drawer open sensor
Separation from the drawer
Disallowed
Separation of the bill compartments from the coin com-
partments
Allowed
Bill separator
Number of compartments
5B/8C
Location of the lock:  Front
Method of locking and unlocking:
To lock, insert the drawer lock key into the lock
and turn it 90 degrees counter clockwise.
To unlock, insert the drawer lock key and turn it 90
degrees clockwise.
Key No:
SK1-1
5B/8C
Layout:
SK1-1
L
oc
k
u
n
lo
ck
XE-A303 (V)
OPTIONS
– 4 –
8. USB PORT
[DEVICE]
USB B Type
[OUTLINE]
This ECR has 1 port.
This is used in order to connect with a personal computer.
[SPECIDICATIONS]
1) Transmission rate
USB 2.0 Full Speed Max. 12Mbps 
2) Connector
USB B Type 
3) Pin assign
1Pin 5V 
2Pin -D 
3Pin +D 
4Pin GND
9. BATTERY
9-1. MEMORY BACK UP BATTERY
CHAPTER 2. OPTIONS
1. OPTIONS (NO)
2. SERVICE OPTIONS (NO)
3. SUPPLIES
4. SPECIAL SERVICE TOOLS  (NO)
CHAPTER 3. MASTER RESET AND PROGRAM RESET
1. MASTER RESETTING
Master resetting clears the entire memory and resumes initial values.
Master resetting can be accomplished by using the following procedure:
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically performed
after the power has been plugined the AC cord to the wall outlet.
(This is because if power failure occurs with no battery attached to
the machine, all the memories are lost and the machine does not
work properly after power recovery; this requires the master reset
operation.)
2. PROGRAM RESETTING (INITIALIZATION)
This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode.
Note: In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically per-
formed after the power has been restored.
2
1
3
4
11.0
12.04
2.5
Type:
Rechargeable battery
Number of battery:
1 pcs as standard
NO
NAME
PARTS CODE
PRICE RANK
DESCRIPTION
1
Thermal roll paper
TPAPR6645RC05
BA
5 ROLLS/PACK 
Procedure A: 1) Unplug the AC cord from the wall outlet.
2) Set the mode switch to the PGM position.
3) While holding down both the JOURNAL FEED key
and [CL] key, plugin the AC cord to the wall outlet.
Procedure: 1) Unplug the AC cord from the wall outlet.
2) Wait over 1 muinite for discharging.
3) Set the mode switch to the PGM position.
4) While holding down both JOURNAL FEED key, plugin
the AC cord to the wall outlet.
XE-A303 (V)
HARDWARE DESCRIPTION
– 5 –
CHAPTER 4. HARDWARE DESCRIPTION
1. BLOCK DIAGRAM
< Main parts >
CPU
: M30623MEP-A93GP (Renesus)
ROM 192KByte (MASK) RAM 16KByte
External RAM : 4Mbit (512K 
u
8) CYPRESS CY62148BELL-45ZSXI
External ROM : 4Mbit (512K 
u
8) SPANSION MBM29F400TC-70
Printer
: M-T203/M-T205 (EPSON)
USB controller : M66291GP (Renesus)
Display Front
: LCD 2 line (16 digits) /2 color backlight
POPUP
: 7 digit LED
2. MEMORY MAP
Normal operation: Microprocessor mode (1MByte mode, PM13 = 0)
< External BUS >
External BUS ACCSESS SPEED
CS0/CS2 area : SRAM
; 3 BCLK
: FROM
; 3 BCLK
CS1 area 
: USB controller ; 3 BCLK
CS3 area 
: DISPLAY
; 2 BCLK
*
 1BCLK=62.5ns (at 16MHz)
< External RAM >
The physical address 0800h~26FFFh of the external RAM can be
accessed either from CS2 area 08000h~26FFFh or from RAMBANK=0
of CS0 area 48000h~66FFFh.
The physical address 00000h of the RAM is not used. 
CPU 
 
M16C/62P 
M30623MEP-A93GP 
ROM 192KByte 
RAM  16KByte 
S-RAM 
512KByte
USB 
Controller
M66291GP
LCD 
2 line 
Latch 
 
Latch 
SEG 
Driver 
DIG 
Driver 
LED 
PopUp 7 
Decoder
74HC138 
u
 2 
4 to 16 
KEY 
SWITCH 
KEY 
RETURN  
PRINTER 
M-T203 
M-T205 
 (24V) 
F-ROM 
512KByte
USB 
Type B 
Driver/Sensor
DRAWER 
KEY SCAN  
POWER 
 
5.8V  LED POPUP 
5.0V   
3.3V   
24V    
Ni-MH 
Battery 
00000h  SFR 
00400h  Internal RAM 12KByte 
(00400h-033FFh) 
033FFh 
03400h 
04000h  POPUP Display 04000h  /CS3 16K 
Front Display 04001h 
08000h  External RAM 
External RAM 
External ROM 
/CS2 124K 
124KByte/512KByte
27000h 
28000h  USB 
/CS1 32K 
Controller 
30000h 
/CS0 832K 
RAM Physical adress 
are in parentheses.
40000h 40000h
(00000h) 
(40000h) 
512KByte 
(07FFFh) 
(256KByte 
u
 2 Bank) 
48000h
/CS2 area
Shadow 
50000h
80000h 
512KByte 
60000h
66FFFh (26FFFh) 
67000h
(27000h) 
C0000h 
70000h
D0000h 
FFFFFh 7FFFFh (3FFFFh) (7FFFFh) 
80000h RAM 
BANK=0 
RAM 
BANK=1 
Page of 32
Display