DOWNLOAD Sharp XE-A203 (serv.man5) Service Manual ↓ Size: 3.94 MB | Pages: 34 in PDF or view online for FREE

Model
XE-A203 (serv.man5)
Pages
34
Size
3.94 MB
Type
PDF
Document
Service Manual
Brand
Device
ECR / XE-A203 Service Manual
File
xe-a203-sm5.pdf
Date

Sharp XE-A203 (serv.man5) Service Manual ▷ View online

XE-A203V/A213V
SPECIFICATIONS
– 3 –
5. DISPLAY
1) OPERATOR DISPLAY
Display device
: LCD
Number of line
: 1 line
Number of positions : 16 positions
Color of backlight 
: Yellow / Green
Character form
: 5 x 7 dots
Character size
: 13mm (H) x 99mm (W)
Layout:
2) CUSTOMER DISPLAY
Display device
: LED
Number of line
: 1 line
Number of positions : 7 positions
Color of display
: Yellow / Green
Style
: Pop up type
Character form
: 7 segment + Dp
Character size
: 14.2mm (H) x 7.9mm (W)
Layout:
•  Clerk code or Mode name
The mode you are in is displayed. When a clerk is assigned, the
clerk code is displayed in the REG or OP X/Z mode. For example,
"*01*" is displayed when clerk 01 is assigned.
• Repeat mark
The number of repeats is displayed, starting at "2" and incremental
with each repeat. When you have registered ten times, the display
will show "0". (2
33 ......9303132...)
•  Power save mark
When the cash register goes into the power save mode, the power
save mark (decimal point) lights up.
•  Function message display area
Item labels of departments and PLU/subdepartments and function
texts you use, such as %, (–) and CASH are displayed. 
When an amount is to be entered or entered, "AMOUNT" is dis-
played: When an amount is to be entered, ------- is displayed at the
numeric entry area with "AMOUNT". When a preset price has been
set, the price is displayed at the numeric entry area with "AMOUNT".
•  Numeric entry display area
Numbers entered using numeric keys are displayed here.
Date and time display
Date and time appear on the display in the OP X/Z, REG, or MGR
mode. In the REG or MGR mode, press the [#] key to display the date
and time.
Error message
When an error occurs, the corresponding error message is displayed
in the function message display area. 
Machine state symbols
:
Appears during programming.
:
Appears when an error is detected.
:
Appears when the subtotal is displayed or when the amount ten-
dered is smaller than the sales amount.
:
Appears when the [EX] key is pressed to calculate a subtotal in
foreign currency.
:
Appears when a transaction is finalized by pressing the [TL/NS],
[CH1], [CH2], [CR1] or [CR2] key.
:
Appears when the change due amount is displayed.
Appears in the far-left three positions at the timing of key entry
when the electronic journal (EJ) memory is full. (Depending on
programming.)
:
Appears when the voltage of the installed batteries is under the
required level. You must replace with new ones within two days.
:
Appears when the batteries are not installed, or the installed
batteries are dead. You must replace with new ones immedi-
ately.
:
May appear right below the eighth and ninth places at the timing
of finalization of a transaction when the electronic journal (EJ)
memory is nearly full.
Also appears right below the tenth place when power save mode
is effective.
Appears when programmed date (and time) for EURO modifica-
tion operation is come.
:
Appears when the print roller arm is not locked.
: Appears when the paper is not set or out.
Operator display
Customer display (Pop-up type)
Power save mark display area
Function message display area
Numeric entry display area
Repeat number display area
XE-A203V/A213V
SPECIFICATIONS
– 4 –
6. PRINTER
1) Printer
 • Part number
: M-T53II
 • NO. of station
: 1 (Receipt or journal)
 • Validation
: No.
 • Printing system
: Line thermal
 • No. of dot
: 288 dots
 • Dot pitch
: Horizontal 0.167mm
Vertical
0.174mm
 • Font
: 10 dots (W) u  24 dots (H)
 • Printing capacity : max. 24 characters
 • Character size
: 1.67mm (W) u  4.17mm (H) at 10 u  24 dots
 • Print pitch
: Column distance
2.0mm
Row distance
5.21mm
 • Print speed
: Approximate 60mm/s (Approximate 12 l/s)
 • Paper feed speed : Approximate 60mm/s (Approximate 12 l/s)
(Manual feed)
: Approximate 40mm/s (Approximate 12 l/s)
 • Reliability
: Mechanism LIFE 6 million lines used to high-
quality thermal paper
 • Paper end sensor : Set up
 • Cutter
: No
 • Near end sensor : No
2) Paper
3) Logo stamp
• No
4) Printing area
Number of thermal head heater elements 288 dots
7. DRAWER
[OUTLINE]
•  Standard equipment: Yes (1)
•  Max. number of additional drawers: 1
•  The drawer consists of:
1) Drawer box (outer case) and drawer
2) Money case
3) Coin case
4) Lock (attached to the drawer)
[SPECIFICATION]
1) DRAWER BOX AND DRAWER
2) MONEY CASE
Layout:
3) LOCK (LOCK KEY : LKGIM7331BHZZ)
•  Location of the lock:Front
•  Method of locking and unlocking:
To lock, insert the drawer lock key into the lock
and turn it 90 degrees counter clockwise.
To unlock, insert the drawer lock key and turn it
90 degrees clockwise.
• Key No:
SK1-1
• Paper rolldimension:  57.5 m  0.5mm in width
Max. 80mm
in diameter
•  Paper quality:
High-quality thermal paper
paper thickness: 0.06 to 0.08mm
Nihon seisi thermal paper : TF50KS-E
Oji thermal paper
: PD150R, PD160R
0.167
(4.75)
(4.75)
48 (288 dots)
print area
(max.24 characters)
(units : mm)
57.5±0.5
(Paper dimension)
Model name of the drawer box
SJ-420
Size
355 (W) x 424 (D) x 125 (H) mm
Material
Metal
Bell
Release lever
Standard equipment: 
Situated at the bottom
Drawer open sensor
Separation from the drawer
Disallowed
Separation of the bill compartments from the coin
compartments
Allowed
Bill separator
Number of compartments
5B/8C
5B/8C
SK1-1
L
oc
k
u
n
lo
ck
XE-A203V/A213V
SPECIFICATIONS
– 5 –
8. BATTERY
1) MEMORY BACK UP BATTERY
For memory back up, three alkaline batteries LR6 ("AA"size) are needed.
For memory back up, the dry battery AA (3 pieces) are needed.
1. Memory Holding time :
Approximate 1 year after New dry batteries are inserted.
2. Battery exchange method:
When the indication “LOW BATTERY”  appear on the LCD, batteries
must be exhanged by the following mannor within 2 days.
1) Power on the ECR.
2) Turn Mode switch to “REG” mode .
3) Release the Old dry batteries (3 pieses).
4) Insert the New dry batteries (3 pieses).
5) Confirm the indication “LOW BATTERY” disappear.
2) LOW BATTERY
Low battery indication will appear in upper line of display when the bat-
tery voltage is low.
CASE 1:
When any numeric entry & any item entry is not done or just
after finalization.
The machine can indicate the low battery condition. (Always)
CASE 2:
When numeric entry or item entry is done.
Battery condition will not appear.
Exceptionally, when the power is restored after a power failure, the
low battery condition will appear on the display only when the bat-
tery is low.
And the indicator will disappear after any key entry.
[Display sample]
Note: “NO BATTERY”: When the “NO BATTERY” is display, the master
reset is executed at the timing of “POWER ON”
after the “POWER OFF”.
OPERATER
1234567890123456
NOTE
Low battery.
You have to change the batteries.
LOW BATTERY 
No battery.
You have to change the batteries
immediately.
NO BATTERY  
XE-A203V/A213V
OPTIONS
– 6 –
CHAPTER 2. OPTIONS
1. OPTIONS (No)
2. SERVICE OPTIONS (No)
3. SUPPLIES
4. SPECIAL SERVICE TOOLS
CHAPTER 3. MASTER RESET AND PROGRAM RESET
1. MASTER RESETTING
Master resetting clears the entire memory and resumes initial values.
Master resetting can be accomplished by using the following procedure:
Procedure A:
1) Unplug the AC cord from the wall outlet  or set the
mode switch to OFF Position. 
2) Let the ECR be without the memory back up battery.
3) Wait over 1 muinite for discharging.
4) Set the mode switch to any position except OFF. 
5) Plugin the AC cord to the wall outlet  or turn the
mode switch from OFF Position to another position.
6) Insert batteries before carrying out operation after
master resetting.
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically performed
after the power has been restored.
(This is because if power failure occurs with no battery attached to
the machine, all the memories are lost and the machine does not
work properly after power recovery; this requires the master reset
operation.)
2. PROGRAM RESETTING
(INITIALIZATION)
This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode. 
Procedure:
1) Unplug the AC cord from the wall outlet. 
2) Wait over 1 muinite for discharging. 
3) Set the mode switch to the PGM position. 
4) While holding down the FEED key, plugin the AC
cord to the wall outlet. 
Note: In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically per-
formed after the power has been restored.
NO
NAME
PARTS CODE
PRICE 
RANK
DESCRIPTION
1
Thermal roll paper
TPAPR6645RC05
AY
5roll/pack 80
φ
NO
NAME
PARTS CODE
PRICE 
RANK
DESCRIPTION
1
USB Cable
Page of 34