SRV MODE PROGRAMMING (“SETTING”)
3 – 3
[01 DEVICE CONFIG] - [03 KP#1] / [04 KP#2] / [05 KP#3] / [06 KP#4] / [07 KP#5] / [08 KP#6] [09 KP#7] /
[10 KP#8] / [11 KP#9]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
TERMINAL#
Terminal No.
000 - 254
000
000 :
Self terminal No.
This means local device.
This means local device.
1-254: Except self terminal No.
This means re-routed device.
Re-routing programming is only valid for printer.
CHANNEL#
Channel No.
0 - 7
0
0: No RS232 channel is assigned.
1-7: RS232 channel is assigned.
1-7: RS232 channel is assigned.
PRINTER
Kind of printer
TM-T88 (3) /
T88 (4)
TM-T88 (3)/
T88 (4)
42 digits
TM-U220/230
40 digits
BUILT-IN (820)
BUILT-IN (810)
AUTO CUTTER
Auto cutter
YES
YES
NO
PRINT TYPE
Kitchen printer TYPE
D ADD + S
ADDITION
DOUBLE ADDITION + SINGLE
D ADD.
DOUBLE ADDITION
ADD.+S
ADDITION + SINGLE
S/D
SINGLE / DOUBLE
ADDITION
ADDITION
SECOND KP
Second KP number
0 - 9
0
NAME
KP name
Max.
(Space)
12cheacters
INITIAL FEED#
Initial KP feed line No.
00 - 64
00
SORT RCPT. CUTTING
Sort receipt cut between each sort
group
group
YES
NO
NO
SEQUENTIAL PRINT
Sequential print except header and
footer print from sort group1
footer print from sort group1
YES
NO
NO
UP-800F/810F (V)
SRV MODE PROGRAMMING (“SETTING”)
3 – 4
[01 DEVICE CONFIG] - [14 BCR (SCANNER)
* ER-A6HS1 setting : "BAUD RATE = 4800 bps" , "DATA BITS = 7Bits", "PARITY = ODD", "STOP BIT = 1Bit"
[01 DEVICE CONFIG] - [15 SCALE]
[01 DEVICE CONFIG] - [16 ONLINE]
[01 DEVICE CONFIG] - [17 POLE DISPLAY]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0:
No RS232 channel is assigned.
1-7: RS232 channel is assigned.
BAUD RATE
Transmission speed
4800 bps
4800 bps
9600 bps
19200 bps
DATA BITS
Data bit
7 Bits
7 Bits
8 Bits
PARITY
Parity bit
NON
ODD
EVEN
ODD
STOP BIT
Stop bit
2 Bits
1 Bit
1 Bit
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0:
No RS232 channel is assigned.
1-7: RS232 channel is assigned.
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0: No RS232 channel is assigned.
1-7: RS232 channel is assigned.
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
WAITING TIME
Waiting time untilmessage is display-
yed on POLE.
yed on POLE.
0-3
0
3 digits (0 to 999 seconds)
0 (No display)
0 (No display)
UP-800F/810F (V)
SRV MODE PROGRAMMING (“SETTING”)
3 – 5
2. [02 SYSTEM PRESET]
[JOB#901] : MRS=0102
901-A: 1. EFT easy card
901-B: 1. Tax system
901-C: 1. Rounding system
901-D: 1. TAB setting
[JOB#902] : MRS = 0000
902-A: 1. In-line system
902-B: Not used (Fixed at "0")
902-C: 1. Clerk report format
902-D: 1. EFT terminal
2. Clerk key
[JOB#903] : MRS=6270
903-A: 1. Baud rate of the POS data copy function (bps)
903-B: 1. Symbol of scale entry
903-C: 1. Scale
2. Entry of tare
3. Unit of weight for the scale
3. Unit of weight for the scale
903-D: Not used (Fixed at “0”)
[JOB#904] : MRS=0000
904-A: 1. Printing of date
904-B: 1. Printing of the consecutive No.
904-C: 1. Service charge is contained in ST.
1. EFT easy card
901-A
Default
No
0
★
Yes
2
1. TAX system
901-B
Default
Auto TAX 1 - 6
0
Auto VAT 1 - 6
1
★
Manual VAT 1 - 6
2
Manual VAT 1
3
Manual TAX 1 - 6
4
Auto VAT 1 - 3 and Auto TAX 4 - 6
5
1. Rounding system
901-C
Default
Normal
0
★
SWEDEN
1
DENMARK
4
1.TAB setting
901-A
Default
0.0 1
0.00
2
★
0.000
3
1. In-line system
902-A
Default
No
0
★
Yes
1
1. Clerk report format
902-C
Default
Type 1 : Clerk
0
★
Type 2 : Cashier
1
Type 3 : Clerk in Cashier + Clerk
2
1. EFT terminal
2. Clerk key
902-D
Default
No
7 bit
0
★
8 bit
2
Yes
7 bit
4
8 bit
6
1. Baud rate of the POS data copy function (bps)
903-A
Default
2400
2
4800
3
9600
4
19200
5
38400
6
★
1. Symbol of scale entry
903-B
Default
“LB”
0
“KG”
2
★
1. Scale
2. Entry of tare
3. Unit of
weight for the
scale
903-C
Default
Manual
Disallowed
2id (3id)+2dd
0
1id (2id)+3dd
1
Allowed
2id (3id)+2dd
2
1id (2id)+3dd
3
Automatic
Disallowed
2id (3id)+2dd
4
1id (2id)+3dd
5
Allowed
2id (3id)+2dd
6
1id (2id)+3dd
7
★
1. Printing of date
904-A
Default
Yes
0
★
No
4
1. Printing of the consecutive No.
904-B
Default
Yes
0
★
No
4
1. Service charge is contained in ST.
904-C
Default
No
0
★
Yes
4
UP-800F/810F (V)
SRV MODE PROGRAMMING (“SETTING”)
3 – 6
904-D: 1. Inclusion of tax in base amount of service charge.
[JOB#905] MRS=0100
905-A: Not used (Fixed at “0”)
905-B: 1. Tax printing when taxable subtotal is zero.
2. Tax printing when tax is zero.
905-C: 1. Printing of rounding amount in receipt. (For Australia)
2. Printing format for split pricing entry. (For Australia).
#905-D : Not used (Fixed at “0”)
[JOB#906] : MRS=0031
906-A: 1. Printing of PLU code (DEPT code is never printed.)
2. Entry which makes the PLU/EAN stock counter negative or
entry which makes the PLU/EAN stock counter smaller than
the minimum stock
the minimum stock
906-B: 1. Bottle Return
2. Hash setting
3. Non-turnover
906-C: 1. Split pricing counting
2. Multiplication entry
906-D: 1. EAN/PLU price look up at refund entry
2. Presetting of consective No.
3. Fractional quantity
3. Fractional quantity
1. Inclusion of tax in base amount of service
charge.
904-D
Default
No
0
★
Yes
4
1. Taxable subtotal is
zero.
2. Tax is zero.
905-A
Default
Skip
Print
0
Skip
1
★
Print
Print
4
Skip
5
1. Printing of rounding
amount in receipt
2. Printing format for
split pricing entry
905-C
Default
No
Normal format
0
★
Australia format
1
Yes
Normal format
2
Australia format
3
1. Printing of PLU
code
2. Entry which makes
the PLU/EAN stock
counter negative or
entry which makes
the PLU/EAN stock
counter smaller than
the minimum stock
counter negative or
entry which makes
the PLU/EAN stock
counter smaller than
the minimum stock
906-A
Default
No
Allowed
unconditionally
unconditionally
0
★
Operation allowed
despite error message
despite error message
1
Inhibited
2
Yes
Allowed
unconditionally
unconditionally
4
Operation allowed
despite error message
despite error message
5
Inhibited
6
1. Bottle
Return
2. Hash setting
3. Non-
turnover
906-B
Default
Disable
Disable
Disable
0
★
Enable
1
Enable
Disable
2
Enable
3
Enable
Disable
Disable
4
Enable
5
Enable
Disable
6
Enable
7
1. Split pricing
counting
2. Multiplication entry
906-C
Default
Quantity
Multiplication only
0
Successive
multiplication
multiplication
1
Split pricing
2
FFx (FF sequence +
Split pricing)
Split pricing)
3
★
Package
Multiplication only
4
Successive
multiplication
multiplication
5
Split pricing
6
FFx (FF sequence +
Split pricing)
Split pricing)
7
1. EAN/PLU
price look
up at refund
entry
up at refund
entry
2. Presetting
of consec-
tive No.
tive No.
3. Fractional
quantity
906-D
Default
No
Yes
No
0
Yes
(3-digit decimal
places)
1
★
No
No
2
Yes
(3-digit decimal
places)
3
Yes
Yes
No
4
Yes
(3-digit decimal
places)
5
No
No
6
Yes
(3-digit decimal
places)
7