SRV MODE PROGRAMMING (“SETTING”)
3 – 3
[01 DEVICE CONFIG] - [03 KP#1] / [04 KP#2] / [05 KP#3] / [06 KP#4] / [07 KP#5] /  [08 KP#6]  [09 KP#7] / 
[10 KP#8] / [11 KP#9]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
TERMINAL#
Terminal No.
000 - 254
000
000 :
Self terminal No.
This means local device.
1-254: Except self terminal No.
This means re-routed device.
Re-routing programming is only valid for printer.
CHANNEL#
Channel No.
0 - 7
0
0:  No RS232 channel is assigned.
1-7: RS232 channel is assigned.
PRINTER
Kind of printer 
TM-T88 (3) /
T88 (4)
TM-T88 (3)/
  T88 (4)
42 digits
TM-U220/230
40 digits
BUILT-IN (820)
BUILT-IN (810)
AUTO CUTTER
Auto cutter
YES
YES
NO
PRINT TYPE
Kitchen printer TYPE
D ADD + S
ADDITION
DOUBLE ADDITION + SINGLE
D ADD.
DOUBLE ADDITION
ADD.+S
ADDITION + SINGLE
S/D
SINGLE / DOUBLE
ADDITION
ADDITION
SECOND KP
Second KP number
0 - 9
0
NAME
KP name
Max.
(Space)
12cheacters
INITIAL FEED#
Initial KP feed line No.
00 - 64
00
SORT RCPT. CUTTING
Sort receipt cut between each sort
group
YES
NO
NO
SEQUENTIAL PRINT
Sequential print except header and
footer print from sort group1
YES
NO
NO
UP-800F/810F (V)
SRV MODE PROGRAMMING (“SETTING”)
3 – 4
[01 DEVICE CONFIG] - [14 BCR (SCANNER)
* ER-A6HS1 setting : "BAUD RATE = 4800 bps" , "DATA BITS = 7Bits", "PARITY = ODD", "STOP BIT = 1Bit"
[01 DEVICE CONFIG] - [15 SCALE]
[01 DEVICE CONFIG] - [16 ONLINE]
[01 DEVICE CONFIG] - [17 POLE DISPLAY]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0:
 No RS232 channel is assigned.
1-7:  RS232 channel is assigned.
BAUD RATE
Transmission speed
4800 bps
4800 bps
9600 bps
19200 bps
DATA BITS
Data bit
7 Bits
7 Bits
8 Bits
PARITY
Parity bit
NON
ODD
EVEN
ODD
STOP BIT
Stop bit
2 Bits
1 Bit
1 Bit
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0:
 No RS232 channel is assigned.
1-7:  RS232 channel is assigned.
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0:  No RS232 channel is assigned.
1-7: RS232 channel is assigned.
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
WAITING TIME
Waiting time untilmessage is display-
yed on POLE.
0-3
0
3 digits (0 to 999 seconds) 
0 (No display)
UP-800F/810F (V)
SRV MODE PROGRAMMING (“SETTING”)
3 – 5
2. [02 SYSTEM PRESET]
[JOB#901] : MRS=0102
901-A: 1. EFT easy card
901-B: 1. Tax system
901-C: 1. Rounding system
901-D: 1. TAB setting
[JOB#902] : MRS = 0000
902-A: 1. In-line system
902-B: Not used (Fixed at "0")
902-C: 1. Clerk report format
902-D: 1. EFT terminal
2. Clerk key
[JOB#903] : MRS=6270
903-A: 1. Baud rate of the POS data copy function (bps)
903-B: 1. Symbol of scale entry
903-C: 1. Scale 
2. Entry of tare
3. Unit of weight for the scale
903-D: Not used (Fixed at “0”)
[JOB#904] : MRS=0000
904-A: 1. Printing of date
904-B: 1. Printing of the consecutive No.
904-C: 1. Service charge is contained in ST.
1. EFT easy card
901-A
Default
No
0
Yes
2
1. TAX system
901-B
Default
Auto TAX 1 - 6 
0
Auto VAT 1 - 6
1
Manual VAT 1 - 6 
2
Manual VAT 1
3
Manual TAX 1 - 6
4
Auto VAT 1 - 3 and Auto TAX 4 - 6
5
1. Rounding system
901-C
Default
Normal
0
SWEDEN
1
DENMARK
4
1.TAB setting
901-A
Default
0.0 1
0.00
2
0.000
3
1. In-line system
902-A
Default
No
0
Yes
1
1. Clerk report format
902-C
Default
Type 1 : Clerk
0
Type 2 : Cashier
1
Type 3 : Clerk in Cashier + Clerk
2
1. EFT terminal
2. Clerk key
902-D
Default
No
7 bit
0
8 bit
2
Yes
7 bit
4
8 bit
6
1. Baud rate of the POS data copy function (bps)
903-A
Default
2400
2
4800
3
9600
4
19200
5
38400
6
1. Symbol of scale entry
903-B
Default
“LB”
0
“KG”
2
1. Scale
2. Entry of tare
3. Unit of 
weight for the 
scale
903-C
Default
Manual
Disallowed
2id (3id)+2dd
0
1id (2id)+3dd
1
Allowed
2id (3id)+2dd
2
1id (2id)+3dd
3
Automatic
Disallowed
2id (3id)+2dd
4
1id (2id)+3dd
5
Allowed
2id (3id)+2dd
6
1id (2id)+3dd
7
1. Printing of date
904-A
Default
Yes
0
No
4
1. Printing of the consecutive No.
904-B
Default
Yes
0
No
4
1. Service charge is contained in ST.
904-C
Default
No
0
Yes
4
UP-800F/810F (V)
SRV MODE PROGRAMMING (“SETTING”)
3 – 6
904-D: 1. Inclusion of tax in base amount of service charge.
[JOB#905] MRS=0100
905-A: Not used (Fixed at “0”)
905-B: 1. Tax printing when taxable subtotal is zero.
2. Tax printing when tax is zero.
905-C: 1. Printing of rounding amount in receipt. (For Australia)
2. Printing format for split pricing entry. (For Australia).
#905-D : Not used (Fixed at “0”)
[JOB#906] : MRS=0031
906-A: 1. Printing of PLU code (DEPT code is never printed.)
2. Entry which makes the PLU/EAN stock counter negative or
entry which makes the PLU/EAN stock counter smaller than
the minimum stock
906-B: 1. Bottle Return
2. Hash setting
3. Non-turnover
906-C: 1. Split pricing counting
2. Multiplication entry
906-D: 1. EAN/PLU price look up at refund entry
2. Presetting of consective No.
3. Fractional quantity
1. Inclusion of tax in base amount of service 
charge.
904-D
Default
No
0
Yes
4
1. Taxable subtotal is 
zero.
2. Tax is zero.
905-A
Default
Skip
Print
0
Skip
1
Print
Print
4
Skip
5
1. Printing of rounding 
amount in receipt
2. Printing format for 
split pricing entry
905-C
Default
No
Normal format
0
Australia format
1
Yes
Normal format
2
Australia format
3
1. Printing of PLU 
code
2. Entry which makes 
the PLU/EAN stock 
counter negative or 
entry which makes 
the PLU/EAN stock 
counter smaller than 
the minimum stock
906-A
Default
No
Allowed 
unconditionally
0
Operation allowed 
despite error message
1
Inhibited
2
Yes
Allowed 
unconditionally
4
Operation allowed 
despite error message
5
Inhibited
6
1. Bottle 
Return
2. Hash setting
3. Non-
turnover
906-B
Default
Disable
Disable
Disable
0
Enable
1
Enable
Disable
2
Enable
3
Enable
Disable
Disable
4
Enable
5
Enable
Disable
6
Enable
7
1. Split pricing 
counting
2. Multiplication entry
906-C
Default
Quantity
Multiplication only
0
Successive 
multiplication
1
Split pricing
2
FFx (FF sequence + 
Split pricing)
3
Package
Multiplication only 
4
Successive 
multiplication 
5
Split pricing
6
FFx (FF sequence + 
Split pricing)
7
1. EAN/PLU 
price look 
up at refund 
entry
2. Presetting 
of consec-
tive No.
3. Fractional 
quantity
906-D
Default
No
Yes
No
0
Yes 
(3-digit decimal 
places)
1
No
No
2
Yes 
(3-digit decimal 
places)
3
Yes
Yes
No
4
Yes 
(3-digit decimal 
places)
5
No
No
6
Yes 
(3-digit decimal 
places)
7
Page of 62