DOWNLOAD Sharp UP-800 (serv.man24) Service Manual ↓ Size: 903.1 KB | Pages: 60 in PDF or view online for FREE

Model
UP-800 (serv.man24)
Pages
60
Size
903.1 KB
Type
PDF
Document
Service Manual
Brand
Device
ECR / UP-820N, UP-820F Program Manual
File
up-800-sm24.pdf
Date

Sharp UP-800 (serv.man24) Service Manual ▷ View online

UP-820N/820F (V)
SRV MODE PROGRAMMING (“7 SD CARD MODE”)
8 – 3
4.
SALES DATA (SAVING) (PGM2 & SRV mode) 
All sales data (Daily and term) are saved in SD card.
Maximum 400 times data is kept in SD Card when the SD memory is
not full.
The action is as below.
1) After reading the information of the current sub-folder from
“SRECORD.REC” file, ECR creates the new sub-folder under the
folder for “Sales Data”.
Its folder is named ASCII Character that is indicated the number of
sales data in SD Card.
(Example: “001”, “002”, “003”,...... )
2) Save the below data in new sub-folder that is created above step.
No.
FileName
File/Table 
No.(*1)
Field  (*1)
 1
Date and Time
MTIMTBL
D0
(when a job is operated)
 2
Department
DEPT
01
Field (F1D81002015A01D8)
1 Preset
2 (reserve)
3 Price
4 Text
8 Daily
9 Term
10 Save Daily
12 Consol
13 (reserve)
20 (nothing)
31 (reserve)
40 (reserve)
42 (reserve)
44 (reserve)
45 (reserve)
48 (nothing)
56 Deduction Daily
57 Deduction Term
58 Deduction Save Daily
60 Deduction Consol
61 (reserve)
 3
Department
DEPTBLK
01
Field (000001D8)
24 Clerk Transaction Dept Daily
25 Clerk Transaction Dept Term
26 Clerk Transaction Dept Save Daily
28 Clerk Transaction Dept Dept Consol
29 (reserve)
 4
PLU/EAN Sales
PLU
11
Field (01D801D801D801D8)
8 Daily
9 Term
10 Save Daily
12 Consol
13 (reserve)
24 WASTE Daily
25 WASTE Term
26 WASTE Save Daily
28 WASTE Consol
29 (reserve)
40 COMBO Daily
41 COMBO Term
42 COMBO Save Daily
44 COMBO Consol
45 (reserve)
56 COMBO WASTE Daily
57 COMBO WASTE Term
58 COMBO WASTE Save Daily
60 COMBO WASTE Consol
61 (reserve)
 5
PLU/EAN Preset
PLUPRS
11
Field (B000) 
1 Preset
3 Price
4 Text
UP-820N/820F (V)
SRV MODE PROGRAMMING (“7 SD CARD MODE”)
8 – 4
3) Create the “STATUS.REC” file in new sub-folder when all files are
saved completely.
4) Update the “SRECORD.REC” file for changing the structure of
sub-folder.
(*1) The contents of each file are same as the communication data
of “ONLINE FUNCTION”.
Details of “File No.” and “Table No.” are described in “ONLINE
SPECIFICATION”.
Note: Each files are used only for the software on PC.
5.
EJ DATA  (SAVING) (PGM2 & SRV mode)                                                                   
Electronic journal data is saved in SD card.
Maximum 400 times data is kept in SD Card when the SD memory is
not full.
Note: In case of “SAVE & CLEAR”, after saving EJ data to SD card, the
EJ data in ECR is eresed.
The action is as below.
1) After reading the information of the current sub-folder in
“SRECORD.REC” file, ECR creates the new sub-folder under the
folder for “Electronic Journal”.
Its folder is named ASCII Character that is indicated the number of
sales data in SD Card.
(Example: “001”, “002”, “003”,...... )
2) Save the below data in new sub-folder that is created above step.
3) Create the “STATUS.REC” file in new sub-folder when all files are
saved completely.
4) Update the “SRECORD.REC” file for changing the structure of sub-
folder.
5) In case of “SAVE & CLEAR” job, Save the below data in the folder
for “EJ for ONLINE”.
(If “READ” is written in “STATUS.REC” file, current EJ file in SD card
is deleted and new EJ file is created. (*2)
In the other cases, new EJ records are added to current EJ file data
in SD card.)
6) In case of “SAVE & CLEAR” job, Create (or Update) the “STA-
TUS.REC” file in the folder for “EJ for ONINE” when all files are
saved completely.
 6
PLU/EAN Stock
PLUSTK
11
Field (0400)
6 Stock (Current, Minimum preset)
 7
Clerk Transaction PLU
CLKPLU
18
All fields
 8
Customer Sales
CUSTSALE
21
All fields
 9
Function Text
FUNCTEXT
A2
All fields
10
Transaction
TRANS
31
All fields
11
PLU/EAN Sales by ADD-ON CODE
EANADDON
33
All fields
12
CCD Shift
CCDSHIFT
38
All fields
13
Cashier Data
CSRDATA
41
All fields
14
Cashier Sales
CSRSAL
42
All fields
15 Reset 
Cashier
RESETCSR
43
All 
fields
16
Clerk Data
CLKDATA
51
All fields
17
Clerk Sales
CLKSAL
52
All fields
18
Reset Clerk
RESETCLK
53
All fields
19
Hourly Sales
HOURLY
61
All fields
20
Hourly PLU Group
HOURPLU
62
All fields
21
Daily Net Sales
DAILYNET
71
All fields
22
Daily Net Consol.
DNETCONS
79
All fields
23
Current GT
CURTGT
C4
All fields
24
Consol. GT
CNSLGT
C6
All fields
25
Current Z
CURTZ
C8
All fields
No.
FileName
File/Table 
No.(*1)
Field  (*1)
File Name
Status information
STATUS . REC
File Name
Record structure
SRECORD. REC
File Name
File/Table
No. (*1)
Field  (*1)
EJ Data
EJFILE  .FDS
EJFILE  .SDA
A0
File Name
Status information
STATUS . REC
File Name
Record structure
SRECORD.REC
File Name
File/Table
No. (*1)
Field  (*1)
EJ Data
EJFILE  .FDS
EJFILE  .SDA
A0
File Name
Status information
STATUS.REC
UP-820N/820F (V)
SRV MODE PROGRAMMING (“7 SD CARD MODE”)
8 – 5
7) In case of “SAVE & CLEAR” job, Erase the EJ data in ECR.
(*1) The contents of each file are same as the communication data
of “ONLINE FUNCTION”.
Details of “File No.”, “Table No.” and “Field” are described in
“ONLINE SPECIFICATION”.
Note:
•  If the folder for “Electronic Journal” does not exist in SD memory
card, this job is inhibited.
[“NO FOLDER” ERROR]
•  If the folder for “EJ for ONLINE” does not exist in SD memory card,
this job is inhibited.
[“NO FOLDER” ERROR]
•  SRV#988_B : Control Character is converted to SPACE when EJ
data is saved in SD card 
(*2) “READ” is written by ONLINE JOB “UPLOAD EJ DATA from
SD CARD”.
6.
T-LOG Data  (SAVING) (PGM2 & SRV mode)                                                             
T-LOG data is saved in SD card.
Maximum 400 times data is kept in SD Card when the SD memory is
not full.
Note: In case of “SAVE & CLEAR”, after saving T-LOG data to SD card,
the T-LOG data in ECR is eresed.
The action is as below.
1) After reading the information of the current sub-folder in
“SRECORD.REC” file, ECR creates the new sub-folder under the
folder for “T-LOG data”.
Its folder is named ASCII Character that is indicated the number of
sales data in SD Card.
(Example : “001”, “002”, “003”,...... )
2) Save the below data in new sub-folder that is created above step.
3) Create the “STATUS.REC” file in new sub-folder when all files are
saved completely.
4) Update the “SRECORD.REC” file for changing the structure of sub-
folder.
5) In case of “SAVE & CLEAR” job, Save the below data in the folder
for “T-LOG for ONLINE”.
(If “READ” is written in “STATUS.REC” file, current T-LOG file in SD
card is deleted and new T-LOG file is created. (*2)
In the other cases, new T-LOG records are added to current T-LOG
file data in SD card.)
6) In case of “SAVE & CLEAR” job, Create (or Update) the “STA-
TUS.REC” file in the folder for “T-LOG for ONLINE” when all files
are saved completely.
7) In case of “SAVE & CLEAR” job , Erase the T-LOG data in ECR.
(*1) The contents of each file are same as the communication data
of “ONLINE FUNCTION”.
Details of “File No.” and “Table No.” are described in “ONLINE
SPECIFICATION”.
Note:
•  If the folder for “T-LOG Data” does not exist in SD memory card,
this job is inhibited.
[“NO FOLDER” ERROR]
•  If the folder for “T-LOG for ONLINE” does not exist in SD memory
card, this job is inhibited.
[“NO FOLDER” ERROR]
(*2) “READ” is written by ONLINE JOB “UPLOAD T-LOG DATA
from SD CARD”.
YES/NO = 2/0
              
Control Character  : 0x00 - 0x1F, 0xFE, 0xFF
Space Character  : 0x20
File Name
File/Table
No. (*1)
Field  (*1)
T-LOG Data
TLOGFILE. FDS
TLOGFILE. SDA
88
File Name
Status information
STATUS . REC
File Name
Record structure
SRECORD. REC
File Name
File/Table
No. (*1)
Field  (*1)
T-LOG Data
TLOGFILE. FDS
TLOGFILE. SDA
88
File Name
Status information
STATUS . REC
UP-820N/820F (V)
SRV MODE PROGRAMMING (“7 SD CARD MODE”)
8 – 6
7.
PROGRAMMING DATA
(SAVING / LOADING) (PGM2 & SRV mode)
The below data is saved or loaded.  Files are set in the folder for “Programming Data”.
No.
File Name
File/Table 
No. (*1)
Save Field  (*1)
 1
Department
DEPTDT
01
B0001 (Label, Preset, Price, Text, Dummy)
 2
PLU/EAN
PLUDT
11
B2001 (Label, Preset, Price1, Text, Price2, Key)
 3
LINK PLU
LNKPLUDT
12
8000 (Label, Preset)
 4
CONDIMENT
CONDMDT
14
9000 (Label, Preset, Text)
 5
MIX & MATCH
PROMDT
15
D000 (Label, Preset, Level, Text)
 6
CLERK PLU
CLKPLUDT
18
8000 (Label, Dummy)
 7
EAN PLU CONVERT
EANPLUDT
19
8000 (Label, Preset)
 8
CRATE
CRTDT
1A
9000 (Label, Preset, Text)
 9
PLU INFORMATION TEXT
PLUINFDT
1B
8000 (Label, Preset)
10
ITF PLU CONVERT
ITFPLUDT
1C
8000 (Label, Preset)
11
CUSTOMER PRESET
CUSTDT
20
9000 (Label, Preset, Text)
12
ADDRESS BOOK
ADDBKDT
23
8000 (Label, Dummy)
13
DYNAMIC EAN
DEANDT
32
B2001 (Label, Preset, Price1, Text, Price2, Key)
14
CASHIER PRESET
CSRDT
41
9000 (Label, Preset, Text)
15
CLERK PRESET
CLKDT
51
9000 (Label, Preset, Text)
16
CONTACTLESS CLERK
CONTDT
57
8000 (Label, Preset)
17
MANAGER PRESET
MANGDT
5A
8000 (Label, Preset)
18
EMPLOYEE PRESET
EMPLOYEE
5B
All fields
19
SCROLLING TEXT
SCROLTXT
7B
All fields
20
WORK TIME SHIFT TEXT
WORKTMTX
7C
All fields
21
LOGO TEXT
LOGODT
A1
8000 (Label, Preset)
22
FUNCTION TEXT
FUNCDT
A2
8000 (Label, Preset)
23
DEPT GROUP TEXT
DEPTGDT
A3
8000 (Label, Preset)
24
PLU GROUP TEXT
PLUGDT
A4
8000 (Label, Preset)
25
HOURLY GROUP TEXT
HORLYGDT
A5
8000 (Label, Preset)
26
CURRENCY DESCRIPTOR
CURDESDT
A6
8000 (Label, Preset)
27
FREE TEXT
FRETXDT
A7
8000 (Label, Preset)
28
VP TEXT
VPTXTDT
A8
8000 (Label, Preset)
29
SLIP TEXT
SLPTXTDT
A9
8000 (Label, Preset)
30
PAYEE NAME
PAYNMDT
AA
8000 (Label, Preset)
31
PLU MENU KEY
PLMNKYDT
AB
D000 (Label, Preset1, Preset2, Text)
32
COMBO MEAL
CMBMLDT
AC
8000 (Label, Preset)
33
E.BILL TEXT
EBLTXTDT
AE
8000 (Label, Preset)
34
JOB LOCATION TABLE
JOBLOCDT
B2
9000 (Label, Preset, Text)
35
DIRECT KEY TABLE
DIRKEYDT
B3
8000 (Label, Preset)
36
SCALE TABLE
SCLKEYDT
B4
8000 (Label, Preset)
37
AUTO KEY TABLE
AUTKEYDT
B5
8000 (Label, Preset)
38
STACKED REPORT TABLE
STCRPTDT
B6
8000 (Label, Preset)
39
SERVICE PARAMETER
SRVPGMTB
C1
Table
40
FREE KEY TABLE
FREKEYTB
C3
Table
41
TRAINING CLERK
TRCLKTB
C9
Table
42
TRAINING TEXT
TRTXTTB
CA
Table
43
KEY ATTRIBUTE
KEYATRTB
CE
Table
44
OPTIONAL FEATURE
OPTFERTB
D1
Table
45
VMP1 ID
VMPID1TB
D2
Table
46
VMP2 ID
VMPID2TB
D3
Table
Page of 60
Display