Sharp UP-600 / UP-700 (serv.man31) FAQ ▷ View online

UP-600/700 Frequently Asked Questions
UP-600/700 Frequently Asked Questions
When finalising through CR for an RA transaction,
the CR amounts are not updated, on the General
Report.
You will have to change a setting in PGM, go to
OPTIONS/FUNC SELECT1.and select CR in
RA/PO as UPDATE.
Report Queries
Report Queries
UP-600/700 Frequently Asked Questions
UP-600/700 Frequently Asked Questions
Report Queries
Report Queries
When the TAX rates are set to zero the taxable
amount is not shown on the reports
You will have to set up a Tax rate above zero,
then take your report.
You can then go back to Tax setting and set the
rate back to zero.
The Taxable rate will now be shown on the
report.
UP-600/700 Frequently Asked Questions
UP-600/700 Frequently Asked Questions
Bar Code Scanner
Bar Code Scanner
Queries
Queries
What type of scanner can I use on the UP600/700
and what is the correct cable and configuration to
get it to operate.
Almost all of the Metrologic scanners will work
with this machine.
The cable and configuration is the same as any of
the other sharp machines such as the 610 and
450s
We have included some set-up guides in the
training manual, but you have to check with your
supplier for clarification of model type.
UP-600/700 Frequently Asked Questions
UP-600/700 Frequently Asked Questions
Network Queries
Network Queries
What programming is required to have a Back Up
Master on a network.
You would carry out the normal In- Line set up,
however you would set BACK UP Master to
EXIST in all the slaves and Master.
Then you would perform a RECOVER DECLARE
job on the Master before any operations are
performed.
You should program the slaves followed by the
Back-up Master and finally the Master terminal.