DOWNLOAD Sharp UP-600 / UP-700 (serv.man23) Service Manual ↓ Size: 4.25 MB | Pages: 51 in PDF or view online for FREE

Model
UP-600 UP-700 (serv.man23)
Pages
51
Size
4.25 MB
Type
PDF
Document
Service Manual
Brand
Device
ECR / UP600-700 Program Manual
File
up-600-up-700-sm23.pdf
Date

Sharp UP-600 / UP-700 (serv.man23) Service Manual ▷ View online

[01 DEVICE CONFIG] - [03 KP#1] / [04 KP#2] / [05 KP#3]
 [06 KP#4] / [07 KP#5] /  [08 KP#6]
 [09 KP#7] / [10 KP#8] / [11 KP#9]
DISPLAY: Setting screen
[KITCHEN PRINTER] KP#1-KP#9
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
TERMINAL#
Terminal No.
000-254
000
000 : Self terminal No.
This means local device.
1-254: Except self terminal No.
This means re-routed device.
The built-in printer cannot be re-routed.
Re-routing programming is only valid for printer.
CHANNEL#
Channel No.
0-7
0
0: No RS232 channel is assigned.
1-7: RS232 channel is assigned.
PRINTER
Connected printer name
TM-T88/85
TM-T88/85
TM-T88(2)
TM-U210
BUILT-IN
AUTO CUTTER
Auto cutter function
YES
YES
NO
PAPER SHEET
Paper sheet type selecting
TWO
ONE
ONE
PRINT TYPE
KP printer type
D ADD+S
ADDITION
DOUBLE ADDITION + SINGLE
D ADD.
DOUBLE ADDITION
ADD.+S
ADDITION + SINGLE
S/D
SINGLE / DOUBLE
ADDITION
ADDITION
SECOND KP
Second KP number
0-9
0
NAME
KP name
Max.
12cheacters
(Space)
INITIAL FEED#
Initial KP feed line No.
00-64
00
[01 DEVICE CONFIG] - [12 BCR(SCANNER)]
DISPLAY: Setting screen
[BCR (SCANNER)]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0: No RS232 channel is assigned.
1-7: RS232 channel is assigned.
BAUD RATE
Transmission speed
4800 bps
4800 bps
9600 bps
19200 bps
DATA BITS
Data bit
7 Bits
7 Bits
8 Bits
PARITY
Parity bit
NON
ODD
EVEN
ODD
STOP BIT
Stop bit
2 Bits
1 Bit
1 Bit
ER-A6HS1 setting : "BAUD RATE = 4800 bps" , "DATA BITS = 7Bits", "PARITY = ODD", "STOP BIT = 1Bit"
NOTE: 1. Set the channel No. so that it does not conflict with other devices that are to be connected. If it does, the unit won’t operate normally.
2. Do not use channel No. 2 for the ER-A6HS1. Use other channel Nos.
3. If you want to change the channel No. of the BCR (Scanner), set a channel No. that is other than 0 and does not conflict with other
devices.
[01 DEVICE CONFIG] - [13 SCALE]
DISPLAY: Setting screen
[SCALE]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0: No RS232 channel is assigned.
1-7: RS232 channel is assigned.
NOTE: 1. Set the channel No. so that it does not conflict with other devices that are to be connected. If it does, the unit won’t operate normally.
[01 DEVICE CONFIG] - [14 ONLINE]
DISPLAY: Setting screen
[ONLINE]
DISPLAY
CONTENTS
SELECT ITEM
MRS
NOTE
CHANNEL#
Channel No.
0-7
0
0: No RS232 channel is assigned.
1-7: RS232 channel is assigned.
NOTE: 1. Set the channel No. so that it does not conflict with other devices that are to be connected. If it does, the unit won’t operate normally.
2. Do not use channel No. 2 for the modem. Use other channel Nos.
2. [02 SYSTEM PRESET]
DISPLAY: Setting item select screen
Select "02 SYSTEM PRESET" and press the ENTER key.
DISPLAY: SYSTEM PRESET screen
Select the JOB# to be changed and enter the value.
The content of each JOB# is described below.
[JOB#901] : UP-600/700 MRS=0102
901-A: 1. EFT easy card
1. EFT easy card
No
0
Yes
2
901-B: Tax system
1. TAX system
Auto TAX 1~6
0
Auto VAT 1~6
1
Manual VAT 1~6
2
Manual VAT 1
3
Manual TAX 1~6
4
Auto VAT 1~3 and Auto TAX 4~6
5
901-C: 1. Rounding system
1. Rounding system
Normal
0
SWEDEN
1
DENMARK
4
901-D: 1. TAB setting
1.TAB setting
0.0 
 1
0.00 2
0.000
3
[JOB#902] : UP-600 MRS = 0050
UP-700 MRS = 0000
902-A: 1. In-line system
1. In-line system
No
0
Yes
1
902-B: Not used (Fixed at "0")
902-C: 1. Display format of operater display (LCD)
2. Clerk report format
1. Display format of
operater display
(LCD)
2. Clerk report format
GLU mode
Type 1 : Clerk
0
Type 2 : Cashier
1
Type 3 : Clerk in
Cashier + Clerk
2
CHECK OUT mode
Type 1 : Clerk
4
Type 2 : Cashier
5
Type 3 : Clerk in
Cashier + Clerk
6
902-D: 1. EFT terminal
2. Clerk key
1. EFT terminal
2. Clerk key
No
7 bit
8 bit
Yes
7 bit
8 bit
[JOB#903] : UP-600/700 MRS=8270
903-A: 1. Baud rate of the POS data copy function (bps)
1. Baud rate of the POS data copy function
(bps)
2400
2
4800
3
9600
4
19200
5
38400
6
57600
7
115200
8
903-B: 1. Symbol of scale entry
1. Symbol of scale entry
“LB”
0
“KG”
2
903-C: 1. Scale entry system
2. Entry of tare
3. Unit of weight for the scale
1. Scale
entry
system
2. Entry of
tare
3. Unit of weight
for the scale
Manual
Disallowed
2id (3id)+2dd
0
1id (2id)+3dd
1
Allowed
2id (3id)+2dd
2
1id (2id)+3dd
3
Automatic
Disallowed
2id (3id)+2dd
4
1id (2id)+3dd
5
Allowed
2id (3id)+2dd
6
1id (2id)+3dd
7
903-D: Not used (Fixed at “0”)
Page of 51