Sharp ER-A610 (serv.man2) Service Manual ▷ View online
[JOB#2644]
GUIDANCE TEXT PROGRAMMING
XX :
Guidence Text Number
Text :
Max 12 Characters
Guidence No.
MRS
22
EFT SALE
23
EFT REFUND
CHAPTER 4. GENERAL
INFORMATION
INFORMATION
SSP’s
It should be noted that SSP’s that are supplied for the stand-
ard machine will not work with the EFT EPROM’s. They
should NOT be installed as major problems may result.
ard machine will not work with the EFT EPROM’s. They
should NOT be installed as major problems may result.
In view of this all SSP’s that have been supplied to date are
contained within these EPROM’s, they are :-
contained within these EPROM’s, they are :-
002
003
004
005
080
084
087
003
004
005
080
084
087
2644
X
XX
X
{Text}
ST
Max 12 Char
TL
ERA570 EFT Interface
4
APPENDIX- OPERATION FLOW CHARTS
MODEL
ERA57EFT
ERA61EFT
1. Transaction Cancellation (Before the Card is Entered)
2. Transaction Cancellation (After the Card is Entered)
3. Dealing with Cable Faults
CONTENTS
SHARP ELECTRONICS (UK) LTD
ERA570 EFT Interface
5
1. Cancellation of a Transaction - (Before card is entered)
Note 1 :-
If a transaction is not manually cancelled on the EFT terminal, then the
terminal will bleep at 15 second intervals for upto a period of 1 minute ; after
which time the transaction will be automatically cancelled .
terminal will bleep at 15 second intervals for upto a period of 1 minute ; after
which time the transaction will be automatically cancelled .
Note 2:-
If a transaction has not been cancelled on the ECR prior to cancellation on the
EFT terminal, then the ECR will display " GEN. EFT ERR " . Press the "CL"
key on the ECR to continue.
EFT terminal, then the ECR will display " GEN. EFT ERR " . Press the "CL"
key on the ECR to continue.
Note 3:-
If a transaction is cancelled on the ECR whilst the EFT terminal is
still
processing the transaction, then any attempt to re-finalise the transaction to
the EFT terminal results in " EFT COMS ERR " at the ECR. The transaction
should be cancelled on both ECR & EFT terminal.
the EFT terminal results in " EFT COMS ERR " at the ECR. The transaction
should be cancelled on both ECR & EFT terminal.
1.1 :- Cancelling on ECR before EFT
ECR Displays " EFT SALE "
Press " CL " on ECR
ECR Displays " OP CANCELLED "
( bleep sounds )
Continue Transaction from
Sub-Total
ECR SIDE
EFT SIDE
EFT Displays " WIPE CARD "
Press " CAN/CLR " on EFT
EFT display returns to POS
mode
Press " CL " on ECR
ERA570 EFT Interface
6
1. Cancellation of a Transaction - (Before card is entered)
1.2 :- Cancelling on EFT before ECR
ECR Displays " EFT SALE "
ECR Displays "GEN. EFT ERR "
( bleep sounds )
Press " CL " on ECR
ECR SIDE
EFT SIDE
EFT Displays " WIPE CARD "
Press " CAN/CLR " on EFT
EFT display returns to POS
mode
Continue Transaction from
Sub-Total
ERA570 EFT Interface
7