Sharp ER-A470 (serv.man18) Service Manual / Technical Bulletin ▷ View online
ER-A460/A470:
SETTING IR COMMUNICATION BAUD RATE
SETTING IR COMMUNICATION BAUD RATE
[Service information]
1. Model name:
ER-A460/A470
2. General:
When the models ER-A460/A470 communicate with ER-01FD/02FD at 9600 bps or less via
the IR communications, it has been found that communication errors frequently occur.
When communicating with ER-01FD/02FD, we recommend that you use 19200 bps baud rate
to deal with these communication errors.
3. Description:
IR communication
ER-A460/A470
CE-IR2/IR4 ER-01FD/02FD
∗
When performing data communications via the IR communication, set the baud rate at
19200 bps.
Set the baud rate in the following manner.
1) ER-A460/A470
Set the baud rate at 19200 bps in SRV MODE PROGRAMMING.
[JOB#903-A: IR communication baud rate setting]
903
→ • → ×
→
5BCD
→
TL
Each setting (see the PROGRAMMING MANUAL)
Baud rate setting: 19200 bps
Baud rate setting: 19200 bps
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
Baud rate setting: 19200 bps
Date :
Model :
Ref :
Colour Code :
Page 1
17t April 1996
ERA470
A470-002
White
ELECTRONIC CASH REGISTER
TECHNICAL BULLETIN
Sharp Electronics (UK) Ltd, Technical Support Group
Originators Initials_____________ Supervisors Initials_____________ Approval Date____________
2) ER-01FD/02FD
Set the "DIP SW1" of DIP SWITCH to 19200 bps.
1 2 3 4 5 6 7 8
Display