Sharp ER-A411 / ER-A421 (serv.man2) Service Manual ▷ View online
Page 13
New functions
The separator line print (selected under SRV#920-A) on receipt is done after ST% / ST(-) print line.
Example:
8. Journal paper print skip
[V1.32]
Due to the market request to reduce paper cost it is possible to skip the journal paper print in all modes
(REG-/OP XZ-/X1Z1-/X2Z2-/PGM1-/PGM2-/SD Card-/SRV mode).
By the new SRV#987-B it can be selected if journal paper print is skipped or not.
Note:
If the E-Journal file does not exist, journal paper print is always skipped.
9. Daily Z-report included in Stacked report
[V1.32]
The daily Z-report included in a stacked report range is now stored into the E-Journal after issuing the stacked
report in X1/Z1 mode in all Fiscal modes (German / Netherlands / Norway).
In normal mode the daily Z-report included in a stacked report is already stored to the E-Journal.
10. Toshiba Flash Air card [V1.32]
The new Flash Air card type W-03 is now also supported.
Page 14
Changes / Improvements / Corrections
C O >>> Changes / Improvements / Corrections since V1.10 <<<
C 0.1 E. BILL message is not stored with “All Program Data” to SD card.
This is corrected in this ROM version.
C 1 >>> Changes / Improvements / Corrections since V1.11 <<<
C 1.1 The daily PLU sales report is corrupted in case the PLU Stock file exists.
Condition:
Only in the case that the PLU Stock file has been created the following problem exists in the current S/W
versions.
Problem:
The daily PLU sales report is corrupted in case the PLU Stock file exists and PLU(s) are added or deleted to /
from the normal PLU file.
To resolve the above mentioned corrupted report a Master Reset is necessary.
This is corrected in this version.
C 2 >>> Changes / Improvements / Corrections since V1.20 <<<
C 2.1 Receipt switch “On / Off” function is re-introduced.
In the Netherland Fiscal mode it is now possible to use the Receipt switch On / Off function.
C 2.2 Final key operation does not count up the Bill counter
In the Swedish Fiscal mode the Final key is used to issue a Proforma ticket.
The number of such issued tickets are not counted up in the Bill counter.
C 2.3 Set key positions at Master Reset 2 return to their standard position after fiscalisation.
Auto key and direct key setting return to their default setting.
This is corrected in this version.
C 2.4 Bill Transfer does not count up the cc-no.
In all Fiscal modes the CC-No. is not counted up at Bill Transfer.
This is corrected in this version.
C 2.5 Voided items within a GLU registration are not included in the bill
In German Fiscal mode voided items are missed on the issued bill after G.C.RCPT key operation.
This is corrected in this version.
C 2.6 Deletion of clerk record from clerk file causes “Undefined Code” Error message
After Master Reset the clerk file includes 25 clerk records.
If for example clerk buttons for clerk 1, 2 , 3 and 4 are assigned to the keyboard and following setting is done:
1. Reduce the Clerk File to 3 and save
2. Increase the Clerk file to 4
3. In PGM2 under Personnel add Clerk 4
If now the Clerk 4 button is pressed the Error message of “Undefined Code” comes up.
The Clerk 1, 2, 3 buttons are still working
This is corrected in this version.
Page 15
Changes / Improvements / Corrections
C 3 >>> Changes / Improvements / Corrections since V1.30 <<<
C 3.1 Compulsory EFT key not any longer active
In case of a power failure or unplug from power supply the before defined compulsory EFT key (CH1 – 5 /
CR1 – 9) are not any longer active.
This is corrected in this version.
C 3.2 With Point Transaction custom firmware (Easycard protocol) signature receipt is not printed.
In case of Finland the Easycard protocol used together the Yomani EFT terminal causes that the signature
receipt is not issued at ECR side.
This is corrected in this version.
C 3.3 Recommended Panasonic and Toshiba SD-card types are not adopted
Since the following SD card types are used or are going to use a different component (NAND Flash) causes that
these cards do not function any longer.
Panasonic: From July 2014 production
RP-SDWA04GJK (4GB)
RP-SDWA08GJK (8GB)
RP-SDWA16GJK (16GB)
RP-SDWA32GJK (32GB)
Toshiba: From December 2014 production
SD-BU016G (16GB)
SD-BU032G (32GB)
C 4 >>> Changes / Improvements / Corrections since V1.31 <<<
C 4.1 ECR lock after plug-in / out in Sleep or Off mode
When plug off the ECR during keystroke entry, in OFF mode or during SLEEP mode and plug in again
the ECR will not work probably.
For the ER-A411/A421 the probability of this issue is round about 1/2000.
When this phenomenon occurs a PROGRAM RESET is required.
Fortunately it has no influence to memory and the ECR can be used continuously.
This is corrected in this version.
C 5 >>> Changes / Improvements / Corrections since V1.32 <<<
C 5.1 Sometimes illegal PLU link record occurs
If a PLU is continuously deleted more than 3 times causes:
- If a PLU text is changed also the text of a other PLU is changed
- Both PLUs turnover are updated in one totalizer
Example:
Master reset
Delete PLU11 / Delete PLU12 / Delete PLU13 / Delete PLU14 / Delete PLU15 / Delete PLU16 /Delete PLU18 /
Add PLU30
This is corrected in this version.
Page 16
New / Changed Parameters
C 6 >>> Changes / Improvements / Corrections since V1.33 <<<
C 6.1 Online communication in REG mode
In REG mode position it is not possible to have online communication.
This is corrected in this version.
P1 >>> New / Changed SRV Parameters <<<
P 1.1 Filing
• Group No. 30 (Flash ROM) T-LOG Buffer is added
[V1.10]
• Group No. 31 (File Table No. 112) EFT Print Buffer is added
[V1.20]
P 1.2 Free Key Layout
Extended Key Code List (PLU Menu Keys 1 - 25)
[V1.10]
Key No.
Key Name
Text
137
PLU Menu01
PLU MENU 01
138
PLU Menu02
PLU MENU 02
139
PLU Menu03
PLU MENU 03
140
PLU Menu04
PLU MENU 04
141
PLU Menu05
PLU MENU 05
142
PLU Menu06
PLU MENU 06
143
PLU Menu07
PLU MENU 07
144
PLU Menu08
PLU MENU 08
145
PLU Menu09
PLU MENU 09
146
PLU Menu10
PLU MENU 10
147
PLU Menu11
PLU MENU 11
148
PLU Menu12
PLU MENU 12
149
PLU Menu13
PLU MENU 13
150
PLU Menu14
PLU MENU 14
151
PLU Menu15
PLU MENU 15
152
PLU Menu16
PLU MENU 16
153
PLU Menu17
PLU MENU 17
154
PLU Menu18
PLU MENU 18
155
PLU Menu19
PLU MENU 19
156
PLU Menu20
PLU MENU 20
157
PLU Menu21
PLU MENU 21
158
PLU Menu22
PLU MENU 22
159
PLU Menu23
PLU MENU 23
160
PLU Menu24
PLU MENU 24
161
PLU Menu25
PLU MENU 25
999
INHIBIT
INHIBIT