Sharp ER-A410 / ER-A420 SCANNING (serv.man3) Service Manual ▷ View online

                                                                    
System Presets 
Designs and specification are subject to change without notice                                                                                        Page 5 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Section-1: System Presets 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                               
System Presets
 
Designs and specification are subject to change without notice                                                                                        Page 6 
 
Section-1: SRV Mode Programming 
SRV-mode programmings consist of service programming jobs, which define the 
ERA410/ERA420 system capabilities. The service program settings are printed on the Receipt / 
Journal printer. 
 
1. 
SRV-mode Program Readings: 
List of SRV-mode Program Reports: 
 
SRV-Mode Related Jobs: (X = indication of availability) 
Job No. 
Description 
900 
System Presets / Memory Allocation 
950 
Free Key – Function keys 
951 
Keyboard Layout – Dept & PLU Link Key Position  
990 
Special Service Patch Data 
 
 
2. 
Entering the SRV-Mode 
To enter SRV-mode programming 
 
Procedure: 
1)  Place the mode switch to the SRV’ position   
2)  Place the AC power cord into the wall outlet 
3)  Place the AC power cord into the wall outlet 
 
 
 
 
 
 
CAUTION: 
Never enter the SRV mode in the middle of a transaction – severe damage may result to the sales 
totals. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                               
System Presets
 
Designs and specification are subject to change without notice                                                                                        Page 7 
 
Section-2: Prior to Beginning 
 
The ERA410/A420 POS terminal should be initialized by executing a master reset.  The Program 
and Master Reset operations are available in one of the following three types: 
 
Type 
Description 
Program Reset 
Initializes the hardware and resident program without clearing 
memory and totalizers 
Master Reset-1 
Initializes the hardware and clears the entire memory – restoring 
factory initial values 
Master-Reset-2 
Initializes the hardware and clears the entire memory – restoring 
factory initial values and enabling free key layout of the ERA410/A420 
“fixed keys” 
 
 
1. 
Master Resets: 
The Master Reset procedures are primarily performed during installation and setup of the ERA410 
and ERA420 model cash registers. Each has an important role when installing the equipment. 
 
Follow one the below procedures when you wish to perform a Master Reset. 
 
1. General Rule: 
 
Master Reset: Clears the entire memory and resumes initial values (default program). 
Program Reset: Resumes the initial program without clearing memory. 
 
There are 2 methods for performing a Master Reset operation. 
 
1)  Master Reset-1: Normal Master Reset (out of box setup) 
                                Clears the entire memory and resumes initial values         
 
2)  Master Reset-2: Enables the ability to change the layout fixed keys in addition to executing  
                                the Master Reset-1.     
 
                                Fixed Keys: [0][1][2][3][4][5][6][7][8][9][0][00][000][.][@/FOR][SBTL][CA/AT]           
 
IMPORTANT NOTES: 
      During the Master Reset initialization, the following actions should be noted: 
 
1)  ***MRS*** is displayed on the upper line of the operator display. 
2)  MASTER RESET*** is printed on the journal tape.  
3)  The buzzer will beep 3-times    
    
 
 
 
 
                                                               
System Presets
 
Designs and specification are subject to change without notice                                                                                        Page 8 
 
2. Master Reset-1 Operations: 
 
There are 2 possible procedures to use in performing a Master Reset-1 operation. 
 
Follow the below procedure when you wish to perform a program-reset (initialization) 
 
Procedure A: 
1)  Place the mode switch to the SRV’ position   
2)  Place the AC power cord into the wall outlet 
3)  Depress and hold the [JOURNAL] feed key  
4)  Turn the mode switch from SRV’ -- > SRV position 
 
 
 
Procedure B: 
1)  Remove the AC power cord from the outlet 
2)  Place the mode switch to the SRV position   
3)  Depress and hold the [JOURNAL] feed key  
4)  Replace the AC power cord into the wall outlet 
 
Note:  
***Procedure A must be used to reset the hardware. Procedure B cannot reset the hardware.
 
 
 
Master Reset-2 Operations: 
 
There are 2 possible procedures to use in performing a Master Reset-2 operation. 
 
Procedure A: 
1)  Place the mode switch to the SRV’ position   
2)  Place the AC power cord into the wall outlet  
 
 
 
3)  Depress and hold the [JOURNAL] & [RECEIPT] feed keys  
4)  Turn the mode switch from SRV’ -- > SRV position 
 
 
***The operator display will show the fixed function keys (starting with the [0] key) 
 
5)  Program the Function Keys by depressing the desired location(s). 
6)  Once the [CA/AT] key is placed on the keyboard, ***MRS*** will be displayed and the reset 
process will continued as outlined in Master Reset-1 
 
 
 
 
 
 
 
 
Page of 127