Sharp ER-A280 / ER-A280N / ER-A280F (serv.man11) Driver / Update ▷ View online
ER-A280 Series PC-LINK
8
Export operation
1. Select SD CARD Drive
2. Select “User Folder”
3. Then press "Export" button.
Import operation
1. Select SD CARD Drive
2. Select “User Folder”
3. Then press "Import" button.
Create folder operation
1. Select SD CARD Drive
2. Then press "New folder" button.
3. Following window is shown and enter the folder name.
Setting
Setting items are as follows
Item
Explanation
Data Folder
Data folder to save each data set.
Terminal No.
Terminal No. of target ECR.
(1-999999)
(This number can be set in "ONLINE CONFIG" on ER-A280.)
(1-999999)
(This number can be set in "ONLINE CONFIG" on ER-A280.)
Password
ONLINE communication password
(0000 - 9999)
(0000 - 9999)
Port Number
RS-232 port number
Baud Rate
Communication speed.
57600bps
38400bps
19200bps
9600bps
4800bps
57600bps
38400bps
19200bps
9600bps
4800bps
Duplex
HALF(Half duplex mode)
FULL(Full duplex mode)
FULL(Full duplex mode)
PLU Price
PLU Price level (1 or 2)
Exit
Terminate the PC-LINK software.
ER-A280 Series PC-LINK
9
6.5 Exec
This menu item can be operated in case of any TAB is selected.
Receive
Data of current TAB is received from connected ECR via RS-232.
If "PLU" tab is selcted and executed this command, then "PLU" data will be received from ECR.
Select and Send
Data of current TAB is sent to connected ECR via RS-232.
In case of "PLU" or "DEPT", programming data can be sent partially.
Following dialog is shown and you can select the data which should be sent.
In case of "DEPT" tab.
Button
Functionality
All Select
All items are selected.
All Clear
All items are deselected.
SEND
Selected data will be sent.
Cancel
Cancel this command and close this dialog.
ER-A280 Series PC-LINK
10
In case of "PLU" tab
Button
Functionality
All Select
All items are selected.
All Clear
All items are deselected.
SEND
Selected data will be sent.
Cancel
Cancel this command and close this dialog.
ER-A280 Series PC-LINK
11
6.6 Record
This menu item can be operated in case of “PLU” tab is selected.
New
Create a PLU record.
Code entry window comes up after this menu selected
A new record is created with following default data.
Group
Item
Value
Text Text
PLU.xxxxxxxxxxxx
Price1 0.00
Price2 0.00
Price2 0.00
Price
Minus Not
selected.
Tax1 Not
selected.
Tax2 Not
selected.
Tax3 Not
selected.
Tax4 Not
selected.
Tax5 Not
selected.
TAXABLE
Tax6 Not
selected.
Dept No.
01
OPEN Not
selected.
Amount Entry Type
PRESET Selected.
Age Verification
Not selected.
Auto Delete by Z1
s
Selected.
Normal Not
selected.
Link PLU
Not selected.
Set PLU
Not selected.
PLU Type
Table No.
0
Commission No.
0
PROGRAM
Base Q’ty
0
If entered code is already exists, following error is shown.
“Entered code already exist.”
Delete
Delete selected PLU.
6.7 About
This menu item can be operated in case of any TAB is selected.
A window that shows software name and version information comes up.
Click on the first or last page to see other ER-A280 / ER-A280N / ER-A280F (serv.man11) service manuals if exist.