DOWNLOAD Sharp ER-A280 / ER-A280N / ER-A280F (serv.man11) Service Manual ↓ Size: 454.85 KB | Pages: 31 in PDF or view online for FREE

Model
ER-A280 ER-A280N ER-A280F (serv.man11)
Pages
31
Size
454.85 KB
Type
PDF
Document
Driver / Update
Brand
Device
ECR / PC LINK for ER-A280 Manual
File
er-a280-er-a280n-er-a280f-sm11.pdf
Date

Sharp ER-A280 / ER-A280N / ER-A280F (serv.man11) Driver / Update ▷ View online

ER-A280 Series PC-LINK 
 
 
 
20 
 
 
6.11    LOGO text programming 
 
Logo text programming is available on LOGO TEXT Tab. 
 
 
 
 
Screen construction 
This TAB is constructed only Logo text entry. 
 
Programming items. 
 
Item 
Explanation 
Logo Text 
30characters / line and Max. 6lines of Logo text can be programmed. 
 
Data Transmission 
Data Transmission can be made by pressing "RECEIVE" or "SEND" button. 
 
Button 
Functionality 
RECEIVE 
Receive all Logo text data from ECR via RS-232. 
SEND 
Send all Logo text data to ECR via RS-232. 
 
ER-A280 Series PC-LINK 
 
 
 
21 
 
 
6.12    VAT ID programming 
 
VAT ID programming is available on VAT ID Tab. 
 
 
 
 
Screen construction 
This TAB is constructed only VAT ID entry. 
 
Programming items. 
 
Item 
Explanation 
VAT ID 
Max. 10 digits VAT ID can be programmed. 
 
Data Transmission 
Data Transmission can be made by pressing "RECEIVE" or "SEND" button. 
 
Button 
Functionality 
RECEIVE 
Receive VAT ID data from ECR via RS-232. 
SEND 
Send VAT ID data to ECR via RS-232. 
  ECR side should be set as Sweden fiscal mode. 
ER-A280 Series PC-LINK 
 
 
 
22 
 
 
6.13    ALL RAM Backup/Restore 
 
ALL RAM Backup/Restore is available on "ALL RAM" Tab. 
 
 
 
 
 
Screen construction 
This TAB is constructed only VAT ID entry. 
 
Programming items. 
ALL RAM data can not be modified. 
This supports only upload and download of ALL RAM data. 
ER-A280 Series PC-LINK 
 
 
 
23 
 
 
Data Transmission 
Data Transmission can be made by pressing "RECEIVE" or "SEND" button. 
 
Button 
Functionality 
BACKUP 
Receive ALL RAM data from ECR via RS-232. 
Location and name of the file that the ALL RAM data is stored in is specified by "BACKUP FILE", 
If the file already exists, a dialog box appears. 
It says "Do you overwrite the file?" and it has YES/NO button. 
If YES button is clicked then all RAM data is received and the file is overwritten by the new data. 
RESTORE 
Send ALL RAM data to ECR via RS-232. 
The transmitted data were appointed in "RESTORE". 
ALL RAM data file location is assigned by "RESTORE FILE" 
 
Page of 31